Catalog excerpts

Electrosurgical vessel sealing
Open the catalog to page 1
time oriented performance The everyday practice of using the ThermoStapler® system in the operating room setting indicates that it allows to reduce the time of the performed
Open the catalog to page 2
ThermoStapler® time oriented performance 1 time oriented performance “Medicine usually requires the art of timing.” Ovid The ThermoStapler® vessel sealing system enables permanent sealing of large blood vessels and tissues during open and laparoscopic surgery. The ThermoStapler® system, designed by EMED, is an alternative to the traditional vessel sealing method using many ligatures and staplers. ThermoStapler® system is based on modern bipolar technique. It enables reliable vessel sealing and minimises the patient’s blood loss during the procedure. As a result, less time for blood...
Open the catalog to page 3
2 ThermoStapler® ThermoStapler® versus bipolar technique thermostapler® versus bipolar technique ThermoStapler® versus bipolar technique confidence through technology Bipolar technique While bipolar technique is being used, high frequency current flows between the two ends of the bipolar instrument and focuses solely on the small surface of tissue placed between them. The risk of burns at sites distant from the surgical field is thus minimised. Therefore, bipolar techniques are considered safer than the monopolar modes. Bipolar coagulation and ThermoStapler® — range of applications...
Open the catalog to page 4
ThermoStapler® the idea behind The combination of high temperature and mechanical pressure causes shrinkage of collagen tissue. Under the influence of high temperature, collagen changes its structure and becomes a very durable sealer. Vessels closed with the use of the ThermoStapler® system are capable of withholding significant blood pressure. The efficiency of coagulation, and thus the safety of vessel sealing, is significantly affected by the condition of the used instrument. The sealing effect is proportional to tissue resistance. Any contamination or tissue residues on the surface of...
Open the catalog to page 5
4 ThermoStapler® safety in ThermoStapler® thermostapler® safety in ThermoStapler® confidence through safety Constant monitoring and the AutoStop function of the generator after sealing the vessel prevents tissue overheating, limits the damage to the tissue and significantly reduces the effect of tissue adhering to the tool. To get through a successful operating procedure is always a matter of both — a medical team and instruments the surgeon can relay on. The rule is to pick out instruments in the same way as surgical team, by choosing those that ensure smooth running of any procedure...
Open the catalog to page 6
ThermoStapler®® features and advantages 5 ThermoStapler features and advantages features and advantages setting performance goals Time and cost reducing features of the ThermoStapler® system: • ntegrated system: diathermy, argon coagulation and a vessel sealing module ensures cost i reduction, there is no need to purchase any additional devices • high reliability of the system ensures maximum safety of work • time of operation is significantly reduced • blood loss is significantly reduced, the system allows to economize on sutures and staplers • natural sealing of vessels • ...
Open the catalog to page 7
applications areas of ThermoStapler® application ThermoStapler® is widely used for resections (partial or total) of tumours and organs. It allows a quick and effective sealing of whole bundles of vessels, which are then cut with surgical scissors. Removing a tumour, an organ or a part of it, is quick and bears no risk of haemorrhage. The operated area remains dry almost throughout the entire procedure. General Surgery Tools for open surgery Laparoscopic tools Thyroid resection Parotid gland resection Stomach resection (partial or total) Small intestine resection Colon resection...
Open the catalog to page 8
Tools for open surgery Laparoscopic tools Abdominal hysterectomy Vaginal hysterectomy Resection of an ovary or fallopian tube Radical prostatectomy Bladder resection Kidney resection Cardiosurgery Harvest of saphenous vein Thoracosurgery Resection of lung wedge Resection of lung segment
Open the catalog to page 9
applications strumectomy Collar skin incision. Coagulation of subcutaneous blood vessels with the use of bipolar forceps. Separating the muscles in order to provide access to the thyroid gland. Application scope of the ThermoStapler® system for a strumectomy procedure. Sealing thyroid vessels with the use of ThermoStapler®. Resection of the thyroid gland. Cutting the vessels with the scissors. Haemostasis of subcutaneous blood vessels Standard blade, length 25 mm Cutting muscles ThermoStapler® clamps, smooth, angled, lengt
Open the catalog to page 10
applications procedures on the colon Release of the ascending colon by closing and cutting blood vessels. Closing the blood vessels using the ThermoStapler® instrument While closing blood vessels, a distance of 2 cm from the colon membrane should be maintained. Stomach resection. Cutting sealed blood vessels with scissors. Haemostasis of subcutaneous blood vessels Standard blade, length 25 mm Cutting muscles ThermoStapler® clamps, smooth, angled, length 23 cm Sealing of blood vessels
Open the catalog to page 11
applications haemorrhoidectomy Grasping the haemorrhoid with the appropriate clamp. Tighten the ThermoStapler® tool at the base of the haemorrhoid and activate the current flow. After closing blood vessels, cut off the surplus mucus. In order to avoid damaging the rectum interior constrictor muscle, make sure not tocut off too large a piece of the mucous tissue. ThermoStapler® clamps, smooth,
Open the catalog to page 12
applications vaginal hysterectomy The use of the ThermoStapler® bipolar vessel sealing system is an efficient and safe alternative to the classical trans-vaginal hysterectomy technique using surgical sutures.* Incision of the vaginal mucosa. Directing the uterus to the vagina in order to expose the uterine ligaments. Release of the uterine ligaments: subsequent tightening of the ThermoStapler® tool and closing tissue structures. After ligating the vessels the closed area should be cut with surgical scissors. The procedure should be repeated until the uterus is fully released....
Open the catalog to page 13All EMED catalogs and technical brochures
-
Argo Plasma
4 Pages
-
Accessories for electrosurgery
56 Pages
-
ATOM smart
4 Pages
-
EMED - company brochure
28 Pages
-
Electrosurgery ES 120 SDS
2 Pages
-
es 350 Argon ThermoStapler®
1 Pages
-
Spectrum - Gastroenterology
2 Pages
-
SPECTRUM - Gynaecology
2 Pages
-
ES 350
1 Pages
-
Electrosurgical unit ARTRO
1 Pages
-
Endo - gastroenterology in mind
26 Pages
-
monopolar and bipolar cables
4 Pages
-
neutral electrodes
6 Pages
-
universal resectoscope
6 Pages
-
SDS accessories
10 Pages
-
arthroscopy
3 Pages
-
bipolar accessories
10 Pages
-
monopolar accessories
18 Pages
-
SpectrumLine accessories
10 Pages