Specifications Product Name Classification Power Supply TOP Lesion Generator TLG-20 Class II b AC 100 V ~ 240 VAC 50/60 Hz Temperature Measurement Impedance Measurement Voltage Setting Range Current Setting Range Pulse Width Output Voltage Output Range Output Current 0 ~ 10.00 V (at voltage setting range selection) 0 ~ 10 mA (at current setting range selection) Temperature Setting Monopolar Lesion & PRF, Bipolar Lesion, Tripolar Lesion, Quadpolar Lesion STP Timer Setting Step Temperature Setting 42 ~ 92 ºC (Lesion) 42 ~ 45 ºC (PRF) 1 sec ~ 15 min (Lesion) 1 sec ~ 30 min (PRF & STP / TCPRF & TCSTP) 42 ~ 60 ºC (Lesion only) Monopolar Lesion & PRF & STP / TCPRF & TCSTP 0 ~ 100 Vrms 20 ~ 70 Vrms (PRF, STP) 20 ~ 100 Vrms (TCPRF, TCSTP) Pulse Frequency Setting Pulse Width Setting Pulse Duration 5, 10, 20, 30, 50 msec (PRF, TCPRF) At random (STP TCSTP) , Pulse Pause Time Stimulation Waveform Frequency Output Mode (with temperature control) Output Mode (with temperature measurement) Output Mode (without temperature control) Output Voltage Voltage Setting Range Special Functions Step Temperature (Lesion only) Impedance Sound History Multi-lesion a step ahead To check the effect of anesthesia, the temperature rise is stopped at a temperature below target The tone of the buzzer sound changes following the impedance Export a maximum of 500 operation history files to USB in CSV format Equipped with the Sluijter-Teixeira Pulse mode STP The Key to Medical Innovation Innovation in the fields of Anesthesiology and Pain Management is at the heart of Equip Medikey. Joined by true pioneers, we develop new products with unique features, for safer anesthesia and effective pain treatments. Valuable solutions for many practitioners and patients, all over the world. The new RF, PRF and STP Generator for Pain Management - Build on our extensive research work in association with Dr. M. Sluijter and A. Teixeira - Temperature controlled multi-lesion RF, PRF and STP on 4 ports - Simultaneous transcutaneous TCSTP and TCPRF in 2 pairs - Individual configuration of output settings - Fast and easy navigation Equip Medikey BV / Edisonstraat 16J / 2809 PB Gouda / The Netherlands T +31 182 57 32 93 / info@equip.nl / www.equip.nl Rabobank Utrecht / IBAN NL05 RABO 0158 4999 05 / BIC/SWIFT RABONL2U / KvK 24400829 / VAT NL817000240B01 - Super port

Open the catalog to page 1
TOP LESION GENERATOR TLG-20 - 2

Transcutaneous TCSTP and TCPRF The TOP Lesion Generator TLG-20 is equipped with a special mode for transcutaneous approaches, often used for the treatment of shoulders and knees. With advanced settings for voltage and frequency this program can be configured for an output of up to 2 simultaneous pairs, either in TCSTP or in TCPRF. Quadpolar Mode This quadpolar bridge in lesion mode forms a caloric junction between the deployed needles. The electric current is not passed through a return electrode and this provides you with a very concentrated, full output directly around the treatment site....

Open the catalog to page 2
TOP LESION GENERATOR TLG-20 - 3

Specifications Product Name Classification Power Supply TOP Lesion Generator TLG-20 Class II b AC 100 V ~ 240 VAC 50/60 Hz Temperature Measurement Impedance Measurement Voltage Setting Range Current Setting Range Pulse Width Output Voltage Output Range Output Current 0 ~ 10.00 V (at voltage setting range selection) 0 ~ 10 mA (at current setting range selection) Temperature Setting Monopolar Lesion & PRF, Bipolar Lesion, Tripolar Lesion, Quadpolar Lesion STP Timer Setting Step Temperature Setting 42 ~ 92 ºC (Lesion) 42 ~ 45 ºC (PRF) 1 sec ~ 15 min (Lesion) 1 sec ~ 30 min (PRF & STP / TCPRF &...

Open the catalog to page 3

All Equip catalogs and technical brochures

  1. TLG-10 L

    2 Pages

  2. C-Table

    4 Pages