Product webpage TECHNICAL SPECIFICATION 400 photometric tests/hour 640 tests/hour with ISE Simultaneous measurement items Sample type Serum, plasma, urine, CSF 96 photometric tests , 40 calculation items and 4 ISE parameters Assay method End-point, kinetic, ISE (direct potentiometry) Calibration type Linear (one point, multi point), exponential, polynomial, factor Optical system Reagent Tray 56 refrigerated positions (8-12°C) 5, 20, 50 ml reagent containers Sample Tray 80 positions Outer ring – 50 position for samples Inner ring – 30 positions for blanks, standards, calibrators, controls and ISE solutions Reagent dispensing 2 independent dispensing probes with liquid-level sensor Dispensed volumes: R1 50 – 300 µl with 1 µl step R2 10 – 300 µl with 1 µl step Minimal reaction volume Reaction tray 72 reusable hard glass cuvettes, optical path length 5 mm Mixing system 2 independent stirrers, 3 mixing speeds Levey-Jennigs graphs, Westgard rules Barcode reader Built-in barcode reader Water consumption Operating system: MS Windows XP or MS Windows 7, Pentium 4, RAM 512 MB, HDD 200 GB, resolution 1024 x 768 Power supply Dimensions, weight Fully Automatic Clinical Chemistry Analyzer Automatic clinical chemistry analyzer – open, random access system, STAT samples processing Complete or selected data Erba Lachema s.r.o. Karásek 1d, 621 33 Brno, Czech Republic Tel.: +420 517 077 111, fax: +420 517 077 077 E-mail: [email protected] www.erbalachema.com XL640_0412EN System type Clinical Chemistry Analysis Easily, Quickly, Efficiently
Open the catalog to page 1Available automation of analysis DISPENSING OF SAMPLES AND REAGENTS • Sample volume: 2-70ul (0.2 ul step) • Reagent volume: Rl 50-300 ul (1 ul step) • 3 dispensing probes (sample, Rl, R2) equipped with liquid -level sensor and crash detector • Auto-dilution of samples and calibrators • Clot detection • Minimum reaction volume: 180 ul • Reusable reaction cuvettes MIXING SYSTEM • 3 user selectable mixing speeds QUALITY CONTROL • 4 levels of control material can be used • Levey-Jennigs graphs • Twin Plot diagrams for monitoring of systematic REACTION UNIT WITH WASH STATION • 72 reusable hard glass...
Open the catalog to page 21 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages
2 Pages
2 Pages
6 Pages
4 Pages
2 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
12 Pages
2 Pages
2 Pages
2 Pages