System type Discrete, open, automated, random access, patient prioritized, 1 or 2 Reagent, Bench top system 180 Photometric tests/hour & 400 tests/hour with ISE (optional) Assay modes 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry Reagent Placement 25 positions fixed for Reagents 15 flexible (Reagent/Sample) 2 Rgt/Dil positions at Room Temperature XL-180 Fully Automated Random Access Clinical Chemistry Analyzer Programmable parameters Unlimited test parameters Unlimited calculation items Unlimited Profiles Unlimited Results storage Sample container Primary tube 7 ml (14.5 x 84 mm) or 5 ml (13 x 75 mm) Cup: Standard cup 2 ml Adaptors will be provided for all types. Sample volume Reaction volume Reagent dispensing Photometric system Multi-wavelength static photometer Absorbance Range Separate dedicated mixer -3 Levels Slow/Medium/High Safety mechanism Vertical obstruction detection Capacitance based liquid level sensing Unlimited number of controls Sample placement Sample cum Reagent tray: Max No of Samples: 25 Nos Fixed Sample Position: 10 Nos Flexible Sample/Reagent position 15 Nos. Water consumption Around 3 ltrs per hour STAT samples To be placed in any of the 25 positions on the outer rim Reaction unit Reaction tray : Semi Disposable PMMA Rotor Number of reaction cuvettes : 120 with 5 mm path length Power supply OS-Windows 7 embedded or higher, CPU -P4 or higher, RAM 2GB, HDD - 80GB, USB connectivity. for small and medium laboratories €RBA Diagnostics Mannheim GmbH Mallaustrasse 69-73 68219 Mannheim, Germany Telephone : (+49) 621 8799770 Fax : (+49) 621 8799688 Email : [email protected] Website : www.erbamannheim.com
Open the catalog to page 1• Fully automated. Random access. Discrete Clinical Chemistry Analyzer • Complete open system provides flexibility to program infinite protocols • Throughput of 180 photometric tests/hour b 400 tests/hour with ISE (optional) • Requires only 180 pi reagent volume with sapphire syringe • Onboard cooling for reagents • Primary tube sampling with option of sample cup • Static photometer with 8 multi-Wavelengths ranging from 340 to 700 nm • Probe with pre-heating facility • Dedicated mixer with variable speed: Low, Medium and High • Inbuilt Barcode reader for samples and reagents • Re-usable rotor...
Open the catalog to page 21 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages
2 Pages
2 Pages
6 Pages
4 Pages
2 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
12 Pages
2 Pages
2 Pages
2 Pages