STR 4407V - 120 lt.

STR 4407V - 120 lt.

STR 4407V - 120 lt.

Product catalog summary
Overview: The document provides detailed specifications and standards for the ERYIGIT STR 4407 steam sterilizer, designed for healthcare facilities to sterilize various medical materials.
Specifications:
  • Chamber Dimensions: Single door with a volume of 120 liters, dimensions of 750 mm depth, 400 mm width, and 400 mm height.
  • Door Type: Hinged door with automatic locking for single door; fully automatic vertical sliding door for double door.
  • Control System: PLC with fully automatic operation and touchscreen interface.
  • Display: Color TFT, LCD touchscreen available in sizes 5.7", 7.0", and 10.0".
  • Printer: Integrated thermal printer with 40 characters per line.
  • Communication: RS232 port.
  • Mobility: Easy positioning on 4 castors and firm fixing on suspension legs.
Standards and Compliance:
  • Complies with Medical Device Directive 93/42/EEC, Low Voltage Directive 2006/95/EC, EMC Directive 2004/108/EC, and Pressure Equipment Directive 97/23/EC.
  • Quality Management System Requirements: EN - ISO 9001:2008, ISO 13485:2003, ISO 14001:2004.
  • Sterilization Standards: EN285:2006 + A2:2009.
Operational Features:
  • Programs: Includes standard programs for medical instruments, textiles, rubber articles, liquids, silicone implants, and more, with specific temperature and time settings.
  • Safety Features: Protects against electrical leaks, short circuits, and includes safety valves, HEPA filters, and water level controls.
  • Monitoring: Touchscreen and analogue gauges for chamber, jacket, generator, and air pressure.
Technical Details:
  • Temperature Range: 110°C - 141°C with a working temperature of 134°C.
  • Pressure: Working pressure of 3.2 Bar/Abs with a test pressure of 7 Bar/Abs.
  • Construction: Made from AISI 316 L/Ti stainless steel for the chamber and AISI 304 stainless steel for the door and panels.
  • Steam Type: 97% saturated steam at 4.2 Bar Abs. Pressure.
Installation Requirements:
  • Requires at least 60 cm space on both sides for technical service.
  • Exhaust fan or ventilation funnel needed for heat evacuation.
  • Water quality should be checked by standard analytical test methods.
Contact Information: ERYIGIT Medical Devices Inc., Ankara, Turkey. Tel: +90 312 395 5795; Email: [email protected]
See more

Catalog excerpts

STR 4407V - 120 lt.-1

ERYIGIT's steam sterilizer is offered in a prevacuum configuration and is designed and manufactured for fast and efficient sterilization of textile material, surgical instruments, dressing tools, rubber materials and liquids in a glass container in healthcare facilities. Size of Chamber Chamber Volume Single Door Double Door Door Type Hinged door with automatic locking Chamber Depth Chamber Width Chamber Height Basket Capacity* Door Type Fully automatic vertical sliding door * Basket size (ISO): 600x400x200 mm (LxWxH) ** Basket/container size (STU): 600x300x300 mm (LxWxH). * Single Door Option is available only. ERYIGIT STR 4407 steam sterilizer is designed and manufactured in compliance with the following requirements and standards: Medical Device Directive Device Classification Pressure Equipment Directive Sterilization – Steam sterilizers – Large sterilizers Quality Management System Requirements Medical Devices – Quality management systems – Requirements for regulatory : ISO 13485:2003 purposes Environmental Management Systems – Requirements with guidance for use “Type” tests of ERYIGIT steam sterilizers are performed and certified according to the directives of EN 285 and TS EN 17665-1-2 by The German accreditation company HYGCEN GmbH. Device Control System PLC (Programmable Logic Controller) Operation Mode Fully Automatic / Button Command Display Type Color TFT, LCD Touch Screen Display Sizes Available 40 Character/line, integrated thermal printer Warning System Visual & Audio & Printed Data Storage Monitoring 1000 cycles Addition to Touchscreen, analogue gauges for chamber, jacket, generator and air pressure Easy positioning on 4 castors (2 x swivel) and firm fixing on suspension legs Steam Control Through pneumatic and electric valves Standard Programs Safety & Quality Features Medical & Surgical Instruments (134°C) √ Protects operator from electrical current leaks. √ Short circuit protection. Liquids in Glass Container (121°C) √ Hepa filter for air filtration. √ Water level control with electrodes in generator. √ Water level buoy (at water tank). √ Steam traps for precise exhausting. Bowie & Dick Test (134°C) Vacuum Leak Test Customized Program Capacity Process times are load-dependent and approximate. They refer to full process including drying with an average load. √ Sensors against obstructions on the doors pathway. √ Doors locks under pressure. √ Unable to open both doors at once in Septic-Aseptic models. √ Emergency stop button.

 Open the catalog to page 1
STR 4407V - 120 lt.-2

Test Pressure Test Temperature Working Temperature Working Pressure Chamber (2), Jacket (1), Generator (1) Steam Generator Capacity Pump, liquid ring (2.2KW) Water Level Protection CRES* / AISI 304 steel box Power (3 Phase, 400 ±10 VAC) Test Pressure Test Temperature Working Temperature Construction Body Electrostatic powdered profile steel/AISI 304 stainless 6.0 mm, AISI 316 L/Ti stainless steel ~2.5-3 mm, AISI 316 L stainless steel, full cover 12 mm, AISI 304 stainless steel Panels Surrounding AISI 304 stainless steel Working Pressure * CRES : Corrosion Resistant Stainless Steel Consumption...

 Open the catalog to page 2

All ERYIGIT Medical Devices catalogs and technical brochures

  1. eryigit

    96  Pages

  2. GOLDBERG 250

    2  Pages

  3. medical devices

    43  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.