STR 7712VD - 675 lt

STR 7712VD - 675 lt

STR 7712VD - 675 lt

Product catalog summary
Specifications:
The ERYIGIT STR 7712 steam sterilizer is designed for efficient sterilization of medical materials. It features a chamber volume of 675 liters with dimensions varying for single and double door models. The device is equipped with a hinged or fully automatic vertical sliding door, depending on the model.

Standards and Compliance:
The sterilizer complies with several directives including the Medical Device Directive 93/42/EEC, Low Voltage Directive 2006/95/EC, EMC Directive 2004/108/EC, and Pressure Equipment Directive 97/23/EC. It also meets quality management standards such as ISO 9001:2008 and ISO 13485:2003.

Control and Operation:
The device operates with a PLC system and offers a fully automatic mode with a touchscreen interface. It includes a thermal printer and RS232 communication port. Safety features include protection against electrical leaks, short circuits, and door obstructions.

Performance and Capacity:
The sterilizer supports various programs for different materials, such as medical instruments and textiles, with process times ranging from 20 to 90 minutes. It has a vacuum capacity of 70 liters and operates at a working pressure of 3.2 Bar/Abs.

Construction and Materials:
The chamber is constructed from AISI 316 L/Ti stainless steel, ensuring durability and resistance to corrosion. The device requires RO treated deionized water and has specific water quality requirements.

Installation and Maintenance:
A minimum of 60 cm space is required on both sides for maintenance. The device includes built-in steam and vacuum systems, and installation requires specific drainage and ventilation setups.

Contact Information:
For further details, contact ERYIGIT Medical Devices Inc. in Ankara, Turkey.
See more

Catalog excerpts

STR 7712VD - 675 lt-1

ERYIGIT's steam sterilizer is offered in a prevacuum configuration and is designed and manufactured for fast and efficient sterilization of textile material, surgical instruments, dressing tools, rubber materials and liquids in a glass container in healthcare facilities. Size of Chamber Chamber Volume Single Door Double Door Door Type Hinged door with automatic locking Chamber Depth Chamber Width Chamber Height Basket Capacity* Door Type Fully automatic vertical sliding door 1580 mm * Basket size (ISO): 600x400x200 mm (LxWxH) ** Basket/container size (STU): 600x300x300 mm (LxWxH). ERYIGIT STR 7712 steam sterilizer is designed and manufactured in compliance with the following requirements and standards: Medical Device Directive Device Classification Pressure Equipment Directive Sterilization – Steam sterilizers – Large sterilizers Quality Management System Requirements Medical Devices – Quality management systems – Requirements for regulatory : ISO 13485:2003 purposes Environmental Management Systems – Requirements with guidance for use “Type” tests of ERYIGIT steam sterilizers are performed and certified according to the directives of EN 285 and TS EN 17665-1-2 by The German accreditation company HYGCEN GmbH. Device Control System PLC (Programmable Logic Controller) Operation Mode Fully Automatic / Button Command Display Type Color TFT, LCD Touch Screen Display Sizes Available 40 Character/line, integrated thermal printer Warning System Visual & Audio & Printed Data Storage Monitoring 1000 cycles Addition to Touchscreen, analogue gauges for chamber, jacket, generator and air pressure Easy positioning on 4 castors (2 x swivel) and firm fixing on suspension legs. Steam Control Through pneumatic and electric valves Standard Programs Safety & Quality Features Medical & Surgical Instruments (134°C) √ Protects operator from electrical current leaks. √ Short circuit protection. Liquids in Glass Container (121°C) √ Hepa filter for air filtration. √ Water level control with electrodes in generator. √ Water level buoy (at water tank). √ Steam traps for precise exhausting. Bowie & Dick Test (134°C) Vacuum Leak Test Customized Program Capacity Process times are load-dependent and approximate. They refer to full process including drying with an average load. √ Sensors against obstructions on the doors pathway. √ Doors locks under pressure. √ Unable to open both doors at once in Septic-Aseptic models. √ Emergency stop button.

 Open the catalog to page 1
STR 7712VD - 675 lt-2

Test Pressure Test Temperature Working Temperature Working Pressure Chamber (2), Jacket (1), Generator (1) Steam Generator Capacity Pump, liquid ring (2.2KW) Water Level Protection CRES* / AISI 304 steel box Test Pressure Test Temperature Working Temperature Construction Body Electrostatic powdered profile steel/AISI 304 stainless 6.0 mm, AISI 316 L/Ti stainless steel ~2.5-3 mm, AISI 316 L stainless steel, full cover 12 mm, AISI 304 stainless steel Panels Surrounding AISI 304 stainless steel Working Pressure * CRES : Corrosion Resistant Stainless Steel Consumption Electricity Water (Approximate)...

 Open the catalog to page 2

All ERYIGIT Medical Devices catalogs and technical brochures

  1. eryigit

    96  Pages

  2. GOLDBERG 250

    2  Pages

  3. medical devices

    43  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.