The document outlines the brand identity guidelines for ESCO Industries, emphasizing the correct application of the logo. The logo must always be used in its entirety, with specific letter spacing, and only approved artwork should be used. Variations include color logos for contrasting backgrounds and black and white versions when a second ink color is unavailable.
Medical Gas Terminal Units
ESCO Medicon specializes in designing and manufacturing medical gas terminal fittings that comply with AS2896 standards. Key features include a unique hose sleeve indexing system for gas type identification, easy cleaning and serviceability, and compatibility with SIS hose fittings and connectors. These fittings are widely used in hospitals and healthcare facilities across Australasia.
Technical Specifications
The document provides detailed specifications for medical gas terminal units, including maximum panel thickness, exhaust tube elbow specifications, and features like a key-indexed aluminum color-coded outer clamp ring and a solid brass body. The units are designed for easy maintenance and installation in various medical service panels and pendants.
Procedures for Maintenance
Maintenance procedures for medical gas terminal units include cleaning the outlet and replacing the main valve seal. Specific tools are required, available from ESCO, and care must be taken to avoid eye damage during operations. The document also outlines procedures for inspecting and cleaning needle valves in suction pump-operated terminal units.
Overview
The document provides detailed information about ESCO Medicon's range of medical gas outlets designed to meet the demands of modern medical facilities and comply with the AS2896 standard. These outlets are suitable for various medical gases and applications, ensuring secure and efficient delivery of gases to equipment, patients, or areas.
Product Range
The document lists several types of self-sealing outlets, including those for medical air, oxygen, nitrous oxide, surgical tools, pump suction, and more. Each outlet type is designed to meet specific medical needs and standards.
Technical Specifications
The outlets feature a sleeve index system that complies with AS2896, allowing them to accept SIS connectors. They are designed with a low-profile body for easy installation in shallow walls and include features like a front removable main valve for quick seal replacement and a secondary valve that automatically shuts off the gas supply when the main valve is removed.
Maintenance and Cleaning
The document outlines procedures for cleaning and maintaining the outlets, including the removal and inspection of valves and seals. Specific tools are required for these procedures, which are available from ESCO.
Venturi Operated Suction & Scavenge Units
These units comply with AS2896 standards and feature a driving gas filter that can be cleaned without removing the mounting panel or gas pressure. They are designed to handle drainage fluids without shutting off the gas supply.
Spare Parts
A detailed list of spare parts for various outlet types is provided, including part numbers and descriptions for easy identification and replacement.
Technical Specifications
  • Maximum panel thickness is 2mm.
  • Exhaust tube elbow compatible with 9.5mm bore flexible hose, rotatable through 180 degrees for installation flexibility.
  • Key indexed with aluminum color-coded outer clamp ring for secure panel fixing.
  • Solid brass body and indexing sleeve with a front removable 'live' element air filter.
  • Low profile body (24mm) allows back-to-back installation in shallow depth walls.
  • Separate flow control valve for ease of maintenance.
  • 6.4mm diameter side entry air supply tube.
Medical Gas Outlets
  • Includes self-sealing outlets for medical air, oxygen, nitrous oxide, surgical tools, pump suction, and various gases like carbon dioxide and entonox.
  • Outlets are compliant with AS 2896 standards for connection details and performance.
  • Features a sleeve index system that accepts SIS connectors.
Venturi Operated Suction & Scavenge Terminal Units
  • Comply with AS 2896 standards.
  • Feature a driving gas filter that can be cleaned without removing the mounting panel or gas pressure.
  • In case of drainage fluid entry, the section requiring cleaning can be detached without shutting off the gas supply.
Panel Punching Detail
  • Model GO GS Pump Gas Scavenge outlet is connected to a central vacuum pump system and complies with AS 2896 requirements.
  • Flow rate can be controlled by an inbuilt needle valve.
See more

Catalog excerpts

Medical Gas Outlets & Wall Fittings-1

Designed with a unique Sleeve Index System to comply to AS2896 Standards
 ESCO Medicon MG Series Gas Terminal Units are designed to accept SIS connectors
 Medical Gas Terminal Units (SIS Type) - Spare Parts
 to carry out the following procedures it will be necessary to have some specific tools which are 
 available as a set from ESCO - Catalogue number MGSK
 as well as the Spare Parts Repair Kit MGSK-2 SIS MEDICAL GAS OUTLETS & WALL FITTINGS medical gas fittings that simply work well..
 
 Fully compliant to AS2896
 Unique Hose Sleeve Indexing System (standard) Simple Access to Serviceable Parts for ease of maintenance
 Solid Brass Body & SIS Indexing Ring Construction
 Installation on either Medical Services Panels, Ducts, Pendants or Standard Wall Plates
 Also available in British Standard (BS) fittings
 Hoes, Connectors, Parts & Accessories plus much more..
 TO CLEAN OUTLET AND REPLACE MAIN VALVE SEAL PROCEED AS FOLLOWS
 a. Remove threaded nipple assembly (item 2) by turning anti-clockwise using special 13mm socket spanner.
 b. On Oxygen, Air, Nitrous Oxide and Surgical Tool outlets secondary valve (item 6) will automatically cut off the gas supply. c. Purge the rubbish that may have accumulated in valve or supply pipeline by depressing the secondary valve (item 6) with a small probe.
 Caution - care should be taken during this operation to avoid eye damage 
 d. Remove the main valve (item 3) from threaded nipple (item 2) and examine this ‘O’ring seal (item 4) for damage or deterioration.
 Note - it is fairly common after installation of a pipeline system for copper pipe filings to become embedded 
 in this ‘O’ring which should be replaced to prevent leakage. e. After cleaning the valve seat, check ‘O’ring seal on nipple (item11) for any damage, then reassemble the unit. (SIS Type) Suction Pump Operated Terminal Units - Spare Parts
 Anaesthetic Gas Cat Number MGOPGS (Scavenge Pump)
 While virtually no maintenance is required on this valve, disassembly of needle valve may be carried out as follows
 a. Needle Valve Inspection
 b. Remove needle valve knob (item9) and retaining nut (item8). Unscrew needle valve (item7) and examine the 
 ‘O’ring (item12) for damage or deterioration.
 c. Clean Valve of any foreign matter and reassemble. ® Low Pressure Gas Hose Fittings 
 also available (to suit any requirement)
 Specify Length, Gas Type & Connectors VICTORIA Unit 4, 15 Lillee Crescent, Tullamarine, VIC 3043, Australia T: +61 3 9310 3980 | F: +61 3 9338 5547 ESCO INDUSTRIES BRAND IDENTITY GUIDELINES QUEENSLAND 30B McKechnie Drive, Brisbane Technology Park REPRESENTED IN ALL CAPITAL CITIES
 Australia Eight Mile Plains, QLD 4113, NSW/ACT/VIC/TAS/SA/QLD/NT 7 3219 0305 T: +61 7 3341 9500 | F: +61 & WA 
 (Freecall) T: 1300 879 363 to find your local ESCO Office or Representative NEW ZEALAND HEAD OFFICE
 Unit 37, Slough Business Park
 Holker Street, Silverwater
 NSW 2128, Australia
 APPLICATION The logo should always be used in full. The logotype should never be moved or adjusted. The logo type has been created with specific letter spacing. Always use approved artwork when reproducing the identity. 16 Hugo Johnston Drive, PO Box 12525, Penrose NEW ZEALAND
 Auckland, New Zealand 16 Hugo Johnston Drive, PO Box 12525 Penrose
 THE ESCO GROUP E: [email protected] OF COMPANIES +64 526 1880 Auckland, New9Zealand
 | F: +64 9 580 0606 | Freecall: 0800 663 367 www.escoindustries.com.au
 T: +64 9 526 1880 I F: +64 9 580 0606
 ESCO INDUSTRIES BRAND IDENTITY GUIDELINES APPLICATION The logo should always be used in full. The logotype should never be moved or adjusted. The logo type has been created with specific letter spacing. new cable management product group logo ideas ESCO INDUSTRIES BRAND IDENTITY GUIDELINES Always use approved artwork when reproducing the identity. BRANDS OF THE ESCO GROUP OF COMPANIES ESCO INDUSTRIES BRAND IDENTITY GUIDELINES THE ESCO GROUP OF COMPANIES APPLICATION The logo should always be used in full. The logotype should never be moved or adjusted. The logo type has been created with specific letter spacing. Always use approved artwork when reproducing the identity. APPLICATION THE LOGO The logo should always beESCO INDUSTRIES BRAND IDENTITY GUIDELINES used in full. The logotype should never be moved or adjusted. The logo type has been created with specific letter spacing. APPLICATION The logo should always be Always use approved artwork in full. used when reproducing the identity. Always use approved artwork when reproducing the identity. cable management solutions ESCO INDUSTRIES THE ESCO GROUP OF COMPANIES BRAND IDENTITY GUIDELINES APPLICATION The logo should always be used in full. The logotype should never be moved or adjusted. The logo type has been created with specific letter spacing. Always use approved artwork when reproducing the identity. c able management solutions THE ESCO GROUP OF COMPANIES cable management solutions The logotype should never be moved or adjusted. The logo type has been created with specific letter spacing. GROUP OF COMPANIES THE ESCO THE ESCO GROUP OF COMPANIES ESCO INDUSTRIES BRAND IDENTITY GUIDELINES APPLICATION The logo should always be used in full. The logotype should never be moved or adjusted. The logo type has been created with specific letter spacing. Always use approved artwork when reproducing the identity.

 Open the catalog to page 1
Medical Gas Outlets & Wall Fittings-2

SIS MEDICAL GAS FITTINGS & OUTLETS MEDICAL GAS TERMINAL UNITS MEDICAL GAS TERMINAL UNITS MEDICAL TERMINAL UNITS MEDICAL GAS TERMINAL UNITS Need to supply Medical Gases, Suction or Air to Equipment, Patients or Areas Securely… MEDICAL GASGAS TERMINAL UNITS MEDICAL GAS TERMINAL UNITS SIS SIS Type Type to AS2896 Type SIS to AS2896 Medicon is a internationally recognised SIS Type to the 
 to AS2896 ESCO SISSIS Type to AS2896 Type market leader in AS2896 to AS2896 choose the NEW Medicon Specialty Gas Outlets to suit all vital gas applications
 design and manufacture of Medical Gas Terminal fittings,...

 Open the catalog to page 2

All ESCO Medicon catalogs and technical brochures

  1. ALPHAMAX

    4  Pages

  2. Sigma Series

    34  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.