Airstream Class II, Blosafety Cabinet, Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety

Open the catalog to page 1
Airstream® Class II Biological Safety Cabinet - 2

RS 232 Serial Interface Port Send operational information to Building Management System (BMS) Optional zero volt exhaust and alarm contact Esco AC2 Airflow: OK I: 0.45 m/s Socket: ON SentinelTM Gold Microprocessor Controller Displays all safety information on one screen Centered and angled down for easy reach & viewing Selectable Quickstart mode for fast operation Curved Corner & Glass Side Large corner radius for easy cleaning Easy to reach service fixture and outlets Stainless steel side wall is available (AC2-S and AC2-D variant) Divided Work Tray Easy to lift and clean Single-piece...

Open the catalog to page 2
Airstream® Class II Biological Safety Cabinet - 3

Airflow Sensor ■ Monitors real-time airflow ■ Alert the user if airflow is Energy Efficient ECM Motor ■ The most energy efficient Class II Biosafety Cabinet in the world 70% Energy savings compared to AC motor Stable airflow, despite building voltage fluctuations & filter m Night Setback mode to further reduce power consumption by 60% input voltage ULPA Filter ■ 10x Filtration efficiency of HEPA filter m Creates ISO Class 3 work zone instead of industry-standard ISO Class 5 T\ Esco cabinets use ULPA filters (per instead of HI3 HEPA filters used on many BSCs in the market. HEPA filters only...

Open the catalog to page 3
Airstream® Class II Biological Safety Cabinet - 4

Cabinet Filtration System Dynamic air barrier, where inflow and forward-directed downflow air converge Ambient air is pulled through front grille to create inflow, without going into the work surface. Inflow is joined by half of the downflow, to create front air curtain that is fine-tuned to create a large performance envelope. The combined air stream travels through the back air column towards the blower. Approximately 1/3 of the air in the common plenum is exhausted through the ULPA filter to the room. The remaining 2/3 of the air is passed through the downflow ULPA filter and into the...

Open the catalog to page 4
Airstream® Class II Biological Safety Cabinet - 5

Model AC2 Biological Safety Cabinet Technical Specifications 250mm (9.8“) 15. Ergonomic Dual Posture Stainless Steel Arm Rest 2. Second blower, for exhaust (AC2-D & AC2-G) 9. Curved Front Panel 1 6. Esco Sentinel™ Gold microprocessor control system 3. Downflow ULPA / H14 Filter 10. Angled down LCD and control panel 5. Removable paper catch (with optional pre-filter) 17. Tempered Glass Sliding Sash Window 18. Ergonomic sash handle 6. Exhaust Collar (optional) 7. Exhaust ULPA / H14 Filter 19. Stainless Steel Work Tray (available in single and 13. Electrical outlet Retrofit Kit provision (1 on...

Open the catalog to page 5
Airstream® Class II Biological Safety Cabinet - 6

TECHNICAL SPECIFICATIONS Glass Side: 230 V, 50/60 Hz Stainless Steel Side: 230 V, 50/60 Hz Stainless Steel Side: 115 V, 50/60 Hz Nominal Size Depth without arm rest Depth with arm rest Height Gross Internal Dimensions (W x D x H) Depth Height Usable Work Area Tested Opening Working Opening Average Airflow Velocity Exhaust Airflow Volume Required Exhaust With Optional Thimble Exhaust Collar Static Pressure For Optional Thimble Exhaust Collar ULPA Filter Typical Efficiency Fluorescent Lamp Intensity (lux) Fluorescent Lamp Intensity (ft-cd) Sound Emission* 1.2 mm (0.05") 18 gauge...

Open the catalog to page 6
Airstream® Class II Biological Safety Cabinet - 7

TECHNICAL SPECIFICATIONS Glass Side: 230 V, 50/60 Hz Stainless Steel Side: 230 V, 50/60 Hz Nominal Size Depth without arm rest Depth with arm rest Height Gross Internal Dimensions (W x D x H) Tested Opening Working Opening Average Airflow Velocity Usable Work Area Unfiltered / potentially contaminated air Room air / Inflow air Exhaust Airflow Volume Required Exhaust With Optional Thimble Exhaust Collar Static Pressure For Optional Thimble Exhaust Collar >99.999% at 0.1 to 0.3 micron, ULPA as per IEST-RP-CC001.3 USA ULPA Filter Typical Efficiency >99.999% at MPPS, H14 as per EN 1822 EU Sound...

Open the catalog to page 7
Airstream® Class II Biological Safety Cabinet - 8

ESCO Global Network ART Equipment Biological Safety Cabinets CO2 Incubators Cold Storage Compounding Pharmacy Equipment Containment / Pharma Products Ductless Fume Hoods Lab Animal Research Products Laboratory Fume Hoods Laboratory Incubators Laboratory Ovens Laminar Flow Cabinets Laboratory Freeze Dryers PCR Cabinets PCR Thermal Cyclers Powder Weighing Balance Enclosures The Esco Group of Companies is a global life sciences tools provider with sales in over 100 countries. The group is active in lab equipment, pharma equipment and medical devices. Manufacturing facilities are located in...