Overview: The document provides technical specifications and features of ETS-Lindgren's LRW Series Single and Dual Line Filters, designed for standard requirements with a frequency range of 14 kHz to 40 GHz. These filters are UL Listed and comply with UL-1283, the Low Voltage Directive (2006/95/EC), and IEC 60939 standards.
Key Features:
  • Frequency Range: 14 kHz to 40 GHz
  • Single and Dual Line configurations
  • Maximum Voltage: 277V to GND, 480V Line to Line
  • Insertion Loss: 100 dB per MIL-STD-220C
Compliance and Certification: The filters are UL Listed and meet or exceed 100 dB insertion loss as per MIL-STD-220C. They are manufactured in accordance with the latest UL-1283 standards and comply with the Low Voltage Directive and IEC 60939. ETS-Lindgren is ISO 9001:2008 registered for the fabrication of various system components.
Product Specifications: The document lists various models of the LRW Series with their current ratings, dimensions, and weights. For example, the LRW-2005-S1 model has a current rating of 5 Amps, dimensions of 55.9 cm x 20.3 cm x 15.2 cm, and a weight of 10.9 kg.
Installation: The filters come with mounting penetration and hardware for direct installation through a shielded wall.
Contact Information: For further details or current specifications, contact the ETS-Lindgren Sales Department.
See more

Catalog excerpts

LRW-Series-1

Single and Dual Line Filters LRW Series FEATURES: Frequency Range: 14 kHz to 40 GHz n Single and Dual Line n Mild Performance: For Standard Requirements n Maximum Voltage: 0-60 Hz: 277V to GND 480V Line to Line n Insertion Loss: Per MIL-STD-220C: 100 dB n ETS-Lindgren’s LRW Series Filters ETS-LINDGREN’S LRW SERIES SINGLE AND DUAL LINE FILTERS are all UL Listed. LRW series filters come with mounting penetration and hardware for direct installation through a shielded wall. All LRW Power Line Filters are designed and manufactured to the most current version of UL-1283 and in accordance with the Low Voltage Directive (2006/95/EC) and IEC 60939. All LRW series filters meet or exceed 100 dB insertion loss from 14 kHz to 40 GHz as measured per MIL-STD-220C. Series LRW Insertion Loss No Load (14K) The UL record covering these filters is located in Follow-Up Services Inspection Procedure File E116566. ETS-Lindgren is ISO 9001:2008 registered through DNV for fabrication of antennas, absorbers, filters, shielding, shielded doors and other system components. Series LRW Insertion Loss at Full Load (40K)

 Open the catalog to page 1
LRW-Series-2

Single and Dual Line Filters LRW Series Installation Diagram CURRENT RATING HEIGHT “A” AMPS Phone + 1.512.531.6400 l [email protected] l www.ets-lindgren.com Offices in the US, Brazil, Germany, Finland, UK, France, India, Japan, Singapore, China, Taiwan Information presented is subject to change as product enhancements are made. Contact ETS-Lindgren Sales Department for current specifications.

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.