Alien X
40Pages

{{requestButtons}}

Catalog excerpts

Alien X - 3

|eurocolumbus ////M"' C-ARM EVOLUTION —

Open the catalog to page 3
Alien X - 4

Eurocolumbus was born in 1972; during 2004 it was the first Italian company to equip its C-arms with Flat Panel Detectors (then produced and marketed by VARIAN, now named VAREX); this generated a very rapid technological growth. In the following years the final product was totally updated and renewed while following the original project, which was based on an isocentric and motorized C-arm, very safe thanks to the anti-collision sensors and a generator separated from the X-Ray tube. Eurocolumbus is the only Italian manufacturer of C-arms that can boast a real internal R&D department. The...

Open the catalog to page 4
Alien X - 7

EtherCAT Eurocolumbus was the first Italian company to use the new EtherCAT technology, by far the fastest Ethernet technology. EtherCAT allows synchronization times with magnitude of nanoseconds. The use of EtherCAT technology brings significant benefits in terms of speed and reliability to all the Applications developed and therefore installed on the systems. The efficiency of the Applications increases thanks to the reduction of waiting times in the transitions between the various phases of the processes. Movement control Exposure time control Anticollision The heart of the machine is...

Open the catalog to page 7
Alien X - 8

Acquisition algorithm The big turning point was during 2012 ! Eurocolumbus abandoned the Windows O.S. and switched to LINUX, the true real time O.S.. Fly5, the software developed under LINUX by Eurocolumbus R&D, is able to process radiological images with a maximum resolution of 3k x 3k in real time. All the images are acquired, processed and stored in 16 bits, taking profit of best technologies available on the market. In order to guarantee full compliance with clinical requirements and not to create artifacts, no digital compression is performed on the images. In order to obtain...

Open the catalog to page 8
Alien X - 9

The heart of the algorithm consists in a Multi-Scale analysis with pyramidal decomposition of the images, based on the representation in terms of wavelet, then waves confined both in space and in spatial frequency. The RAW image obtained by the detector undergoes a series of filtering and sub-sampling that allow to extract and separate the different levels of information of the image according to a Gaussian-Laplacian decomposition.

Open the catalog to page 9
Alien X - 10

The EDM and EAC functions guarantee images always perfectly exposed and with the lowest possible dose, even if the image is not perfectly centered. The two functions act in real time thanks to a closed loop control “image quality radiological parameters” total control at every point of acquisitio

Open the catalog to page 10
Alien X - 11

Each body district requires different settings of the radiological parameters The EDM function (Eurocolumbus Dose Management) adapts the dose to the characteristics of the body district under examination, the evaluation is made at each point of the detector. The EAC function (Eurocolumbus Automatic Control) determines and sets the correct exposure time to obtain the lowest possible dose. Both functions act in real time.

Open the catalog to page 11
Alien X - 12

2019 was born from the experience gained in over 15 years of work on Flat Panel Detectors technology and in over 40 years working on traditional C-arms. Eurocolumbus introduce our made in Italy The current product, alien X, has been completely redesigned compared to the previous famous and successful series. This guarantees that it can satisfy all Hospital Departments requirements, without any distinction.

Open the catalog to page 12
Alien X - 17

Since the beginning Eurocolumbus adopted the technical choice of having the generator separated from the X-Ray complex; the EPB system (Eurocolumbus Power Boost) has been developed and introduced in series production from about one year. EPB has been specifically developed for clinical applications where high instantaneous power peaks are required (impulsive absorption), while allowing the withdrawal of the necessary energy from existing electrical network equipped with 13 - 16 A electrical plugs. The EPB system stores a large amount of energy inside itself; then this energy is made...

Open the catalog to page 17
Alien X - 18

X-Ray tube alien X uses the latest generation X-Ray tubes with Titanium, Zirconium and Molybdenum (TZM) plate. The advantages compared to the use of pure Molybdenum plates are: better resistance to creep, higher recrystallization temperature, higher heat resistance. • 300 - 400 kHU anodic capacity • High speed anode rotation • 0,3-0,5 or 0,3-0,6 mm dual focal spots

Open the catalog to page 18
Alien X - 19

WAD + EHC WAD (Water Aided Dissipation): cooling system of the X-Ray tube; thanks to the combination of dielectric oil management inside the radiological complex, the coolant and the advanced heat exchanger, there are no fans in the sterile field. EHC (Eurocolumbus Heat Control): real-time control of the heat produced with immediate actions to change frames / sec and/or pulse and/or imaging and radiological parameters, to ensure optimal system working and avoid overheating.

Open the catalog to page 19
Alien X - 20

Manual Motorized HYBRID The movement of the arm of alien X can take place both with manual and motorized motion; manual motion is easy and the system can be used simply and ergonomically thanks to the dedicated handles. The hybrid movement allows the combined use of both the motions. As an option, the motorization of the horizontal movement is also available. This option is mandatory if the availability of the EIC package is required. EIC It ensures combined and simultaneous control of the four motorized movements: vertical, horizontal, RAO-LAO and CRA-CAU. In this way, isocentrism is...

Open the catalog to page 20
Alien X - 21

EPD anticollision system Safety first! The new volumetric systems EPD (Eurocolumbus Proximity Detection) can have different and independent set ups for the FPD side and for the X-Ray tube side, both upper and lower covers. EPD perceives the proximity of anatomical or metal parts by simultaneously stopping the movement of the C-arm before any collision. There are two fundamental reasons why this system is called “smart”: First: the system intervenes and stops all the movements of the C-arm “before” the collision takes place. Second: in case the active anti-collision system intervenes during...

Open the catalog to page 21

All Eurocolumbus catalogs and technical brochures

  1. Alien X 3D

    1 Pages

  2. CT 70T

    10 Pages

  3. Alien E

    40 Pages