The E-MAGIC® PLUS is a sirolimus-eluting cobalt chromium coronary stent system designed to prevent restenosis by releasing sirolimus, a drug with antiproliferative and anti-inflammatory effects. The stent is coated with a biodegradable polymer that ensures controlled drug release.

Sirolimus
Sirolimus, derived from the bacterium Streptomyces hygroscopicus, inhibits cell cycle progression and immune cell activation, reducing vascular smooth muscle cell proliferation and inflammation.

Biodegradable Polymer
The stent coating consists of a biodegradable polymer made from poly L-lactide (PLLA) and poly DL-lactide-co-glycolide (PLGA), providing a durable and thin layer for controlled sirolimus release.

Technical Specifications
  • Stent Material: Cobalt Chromium L605
  • Stent Strut Thickness: 60 µm
  • Stent Diameters: 2.25 to 4.00 mm
  • Stent Lengths: 8 to 40 mm
  • Design: Laser cut, hybrid open & closed cell
  • Recoil: < 5%
  • Nominal Stent Foreshortening: < 5%

Delivery System
  • Type: Rapid Exchange
  • Balloon Material: Polyamide
  • Nominal Pressure: 8 atm
  • Rated Burst Pressure: 16 atm (varies with size)
  • Guide Catheter Compatibility: 5 F
  • Max. Guide Wire: 0.014" (0.36 mm)

Benefits
  • Semi-compliant balloon with quick deflation
  • Thin and flexible stent struts
  • Biodegradable polymer for controlled drug release
  • Sirolimus coating for anti-restenotic properties

Contact Information
Eurocor Tech GmbH, Bonn, Germany. Part of Opto Circuits Group.
See more

Catalog excerpts

E-MAGIC PLUS CORONARY SIROLIMUS DES CC-1

SIROLIMUS-ELUTING COBALT CHROMIUM CORONARY STENT SYSTEM

 Open the catalog to page 1
E-MAGIC PLUS CORONARY SIROLIMUS DES CC-2

SIROLIMUS-ELUTING COBALT CHROMIUM CORONARY STENT SYSTEM COATING The E-Magic Plus is a drug eluting stent delivery system as the stent is coated with the active pharmaceutical ingredient sirolimus (1.3µg/mm²) within a biodegradable PLLA & PLGA matrix. The new alliance of a fully biodegradable polymer, together with sirolimus efficiency to prevent restenosis, assures homogeneous drug distribution and uniform release kinetics. Such combination is expected to demonstrate long term efficacy as well as extremely low rates of late stent thrombosis. anti-inflammatory effect Sirolimus antiproliferative...

 Open the catalog to page 2
E-MAGIC PLUS CORONARY SIROLIMUS DES CC-3

SIROLIMUS-ELUTING COBALT CHROMIUM CORONARY STENT SYSTEM STENT Stent Material Stent Strut thickness (µm) Stent Design Laser cut, hybrid open & closed cell design Stent Coating Sirolimus (1.3µg/mm²) within a biodegradable PLLA & PLGA matrix Nominal Stent Foreshortening DELIVERY SYSTEM Delivery System Rapid Exchange Balloon Material Balloon Characteristics Nominal Pressure Rated Burst Pressure 16 atm except balloon diameter 3.5 mm/ length ≥ 36 mm (14 atm) and balloon diameter 4.0 mm/ length ≥ 32 mm (14 atm) Shaft outer Diameter Radiopaque Markers Guide Catheter Compatibility Crossing Profile

 Open the catalog to page 3
E-MAGIC PLUS CORONARY SIROLIMUS DES CC-4

SIROLIMUS-ELUTING COBALT CHROMIUM CORONARY STENT SYSTEM BENEFITS  Semi-compliant balloon with an average deflation time of 6 seconds  Short, thin and soft tip  Open cell stent design enables optimal access to side branch  Stent strut thickness of only 60 µm for maximal stent flexibility and minimized trauma to the vessel wall  Reduced recoil of dilated stents  Biodegradable PLLA & PLGA polymer  Sirolimus coating with active pharmaceutical and anti-restenotic properties  Drug release within 30–40 days after implantation PRODUCT ORDERING INFORMATION E-MAGIC  PLUS Sirolimus-eluting cobalt...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.