1. Catalogs
  2. Eurocor
  3. Eurolimus™ Sirolimus Eluting Coronary Stent System / coronary stent / cobalt-chromium / drug eluting

Eurolimus™ Sirolimus Eluting Coronary Stent System / coronary stent / cobalt-chromium / drug eluting

Eurolimus™ Sirolimus Eluting Coronary Stent System /  coronary stent / cobalt-chromium / drug eluting

Eurolimus™ Sirolimus Eluting Coronary Stent System / coronary stent / cobalt-chromium / drug eluting

Product catalog summary
Overview: The EUROLIMUS™ Sirolimus Eluting Coronary Stent System is designed to improve coronary artery treatment through a combination of advanced stent design and drug delivery technology. It features a sirolimus-coated stent within a biodegradable PLGA matrix, offering antiproliferative and anti-inflammatory effects.
Stent Design: The stent has ultra-thin 65 µm struts, providing a lower crossing profile and easier crossability, reducing vessel injury. It features a 9-crown structure for excellent vessel coverage and homogeneous drug distribution. The interlinks are designed for increased deliverability and vessel adaptation.
Drug and Coating: Sirolimus, an antiproliferative and anti-inflammatory drug, is used at a dose of 1.4 µg/mm². The coating is asymmetrical, with a matrix thickness of 3-5 µm, ensuring coating integrity up to a 4.5 mm expansion. The biodegradable polymer PLGA 85/15 ensures a durable yet thin coating.
Clinical Insights: A study involving 367 patients across two European centers (Italy and Greece) showed a stent thrombosis rate of 0.27% and a major adverse cardiac event (MACE) rate of 5.72% over a follow-up period of approximately 25.6 months.
Specifications: The stent is made from cobalt chromium L605, with an expansion range of 2.25 mm to 4.00 mm. It has a mechanical recoil of less than 5% and metal coverage of less than 18%. The delivery system includes a polyamide balloon and a stainless steel proximal shaft, with a usable length of 138 cm.
Ordering Information: The stent is available in various lengths and balloon diameters, with specific product codes for each configuration. A compliance chart provides details on balloon diameter changes under different pressures.
Conclusion: The EUROLIMUS™ stent system combines innovative design and drug delivery to enhance coronary artery treatment, with promising clinical outcomes and a robust design for effective deployment.
See more

Catalog excerpts

Eurolimus™ Sirolimus Eluting Coronary Stent System /  coronary stent / cobalt-chromium / drug eluting-1

Sirolimus Eluting Coronary Stent System 3 Years Shelf life

 Open the catalog to page 1
Eurolimus™ Sirolimus Eluting Coronary Stent System /  coronary stent / cobalt-chromium / drug eluting-2

Sirolimus Eluting Coronary Stent System The Eurolimus is a drug eluting stent delivery system. The stent is coated with the active pharmaceutical ingredient sirolimus (1.4 pg/mm2) within a biodegradable PLGA matrix. Sirolimus • Sirolimus is a drug with an antiproliferative and antiinflammatory effect which is used to coat coronary stents. • Sirolimus is the generic name of the natural product rapamycin, produced by strains of the bacterium Streptomyces hygroscopicus. • Sirolimus inactivates the TOR protein and thus blocks transition from the G1 phase to the S phase in the cell cycle and therewith...

 Open the catalog to page 2
Eurolimus™ Sirolimus Eluting Coronary Stent System /  coronary stent / cobalt-chromium / drug eluting-3

Sirolimus Eluting Coronary Stent System The Coating makes the difference The alliance of a fully biodegradable polymer, together with sirolimus‘s efficiency to prevent restenosis, assures homogeneous drug distribution and uniform release kinetics. Such combination is expected to demonstrate long term efficacy as well as extremely low rates of late stent thrombosis. Polymer Degradation / Drug Release % Sirolimus release Homogeneous Drug Distribution The Eurolimus coating allows a simultaneous polymer resorption and drug release within 3–4 months, to match the procedure-triggered biological response....

 Open the catalog to page 3
Eurolimus™ Sirolimus Eluting Coronary Stent System /  coronary stent / cobalt-chromium / drug eluting-4

Sirolimus Eluting Coronary Stent System Compliance Chart Pressure (MPa / bar/atm) Rated Burst Pressure | - Do not exceed Product Ordering Information Balloon Diameter (mm) EULI 3.00-10 EULI 3.00-13 EULI 3.00-16 EULI 3.00-18 EULI 3.00-23 EULI 3.00-28 EULI 3.00-33 EULI 3.00-38 EULI 3.00-43 EULI 3.00-48 special request EULI 2.25-10 EULI 2.25-13 EULI 2.25-16 EULI 2.25-18 EULI 2.25-23 EULI 2.25-28 EULI 2.25-33 EULI 2.25-38 EULI 2.25-43 EULI 2.25-48 EULI 2.50-10 EULI 2.50-13 EULI 2.50-16 EULI 2.50-18 EULI 2.50-23 EULI 2.50-28 EULI 2.50-33 EULI 2.50-38 EULI 2.50-43 EULI 2.50-48 EULI 2.75-10 EULI 2.75-13...

 Open the catalog to page 4

All Eurocor catalogs and technical brochures

  1. FREEWAY™

    4  Pages

  2. DIOR®

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.