Density
1 /2Pages

Density

Density
1 /2Pages

Catalog excerpts

Density-1

DENSITY SERIES TECHNICAL SPECIFICATIONS MODEL Density S-NFB Pencil beam Pencil beam STANDARD PROTOCOLS SCAN TIME * (Normal mode) Single detector Multiple detectors Single detector Spine, Femur, Forearm, Whole Body Spine, Femur, Forearm Spine, Femur, Forearm Spine: 119s Femur: 119s Forearm: 95s Whole body (2 meters): 9 min. Spine: 48s Femur: 48s Forearm: 34s Whole body (2 meters): 4 min. Spine: 119s Femur: 119s Forearm: 95s - Spine: 48s Femur: 48s Forearm: 34s - DOSE PATIENT * (Normal mode) Spine: 12.37uGy Femur: 12.37uGy Forearm: 0.82uGy Whole body: 4.71uGy Spine: 15.12uGy Femur: 15.12uGy Forearm: 1.00uGy Whole body: 5.75uGy Spine: 12.37uGy Femur: 12.37uGy Forearm: 0.82uGy - Spine: 15.12uGy Femur: 15.12uGy Forearm: 1.00uGy - SCAN AREA WEIGHT Multiple detectors Spine, Femur, Forearm, Whole body *Time and effective exposure depend on patient’s morphology Principle of operation: Separation: samarium filtered (K-edge) Energies: 40keV, 75keV Filtration: 30,5mm Al eq External shielding: Not required: x-ray safety requirements may be different in some countries Environmental Dose Rate: <0.5µSv/h for typical usage @1m from x-ray source Performance: Precision: <1% Accuracy: <1% Reporting results: BMD, BMC, area, Z-score, T-score, Z-Score %, T-Score % Reference curves: NANHES, local databases Calibration: multi-points BMD and area Continuous Electronics Autocalibration: adaptive peak threshold setting Linearity range: 0,2g/cm² ÷ 2g/cm² Patient weight limit: 160kg X-ray generator: Type: x-ray monobloc, HF, fixed anode, microprocessor controlled stability Tube current: 0.125 - 1.75mA Constant potential source at 86keV Cooling: oil convection Collimator: single hole /multiple holes, 2mm diam. Beam size: 2mm X-ray detector: Type: ultra high efficiency NaI(Tl) scintillator integral line PMT Detector HV : negative, -200 to -1200V, stabilized Environmental requirements: Temperature: 15 to 27°C Humidity: 15% to 80% (non condensing) Minimum room dimensions: 3x3m Power requirements: 230VAC, 500W A different DEXA bone densitometer E U R O T E C M E D I C A L S Y S T E M S s . r. l . is one of the most important companies in Italy designing and manufacturing X-ray devices. Eurotec Medical Systems units are designed, developed a n d m a n u f a c t u r e d i n I T A LY, a i m i n g t o t h e m o s t i n n o v a t i v e technological and mechanical solutions. EUROTEC MEDICAL SYSTEMS is ISO 13485 certified. Software: Protocols: spine, Femur (right/left), Forearm (right/left), Total Body/Body composition (PB and NFB models), Pediatric (optional) Dicom 3.0 compliant (optional) Built-in automatic QC procedures and system diagnostics Bone edge detection: automatic Selectable quality (High resolution, Normal, Fast) Pre-set exam parameters automatically adjusted according to patient’s morphology PC and OS minimum requirements: Operating system: windows 64 - bit (7/8/8.1/10) Memory: 4GB Hard disk: 500GB Display: LCD or LED, 22”, resolution 1920*1080’’ Printer: inkjet or laser color Connection: Ethernet or 802.1n Wi-Fi (optional) Accessories: Washable and anallergic mattress Washable and anallergic pillow Covering clothes EUROTEC MEDICAL SYSTEMS srl Via Aldo Moro 5/7 - 24020 Scanzorosciate (BG) Italy tel: +39 0355297470 - FAX: +39 0350662392 [email protected] - www.eurotec-ms.com A bone densitometer for all: Easy to access for disabled and elderly with mobility problem. Table height is just 60cm. Specification are subject to modifications without prior notice. 22/10/2019 Rev.

 Open the catalog to page 1
Density-2

DENSITY SERIES dVISION The smart Density software OSTEOPOROSIS Osteoporosis is a medical condition in which the bones become brittle and fragile from loss of tissue, typically as a result of hormonal changes, or deficiency of calcium or vitamin D. Osteoporosis is one of the major diseases affecting the elderly and more precisely is the seventh most common complaint. The incidence among people over age 50 is about 50% mostly among women. b a: Normal bones - b:Osteoporosis WHO (World Health Organization) defined osteoporosis based on bone mineral density (BMD). ESSENTIAL DESIGN Density series are...

 Open the catalog to page 2

All Eurotec Medical Systems catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.