Linear actuator CAHB series-4

CAHB series Linear actuator CAHB series with 7 families of linear actuator, virtually maintenance-free, self-locking up to 2 times the rated load and up to IP69K/66M, covers low, medium and high loads for mobile applications, Additional design options are available like limit switches, positioning feedback and manual override. The smart CAHB-20S, CAHB-21S and CAHB-22S offer unique features at a competitive cost with integrated controller and advanced functions. Features New smart version CAHB-20S, -21S and -22S • Integrated controller with I/O and CAN bus SAE J1939 • Motion with soft start/soft...

 Open the catalog to page 4
Linear actuator CAHB series-5

CAHB series Performance overview of the CAHB series Family Integrated controller

 Open the catalog to page 5
Linear actuator CAHB series-6

CAHB-10 Linear actuator Benefits • Designed and tested under demanding conditions • Reliable and cost-effective • Reduced overall set time • Virtually maintenance-free Features • Compact and robust design, IP66S/69K, wide temperature range and corrosion resistant • Integrated limit switches, optional absolute or incremental positioning feedback • Integrated thermal protection Technical data Designation Rated push force Rated pull force Holding force 1) Speed (full load to no load) Stroke Voltage Nominal current 12 V DC 24V DC Duty cycle Ambient temperature Type of protection Weight (at 300 mm...

 Open the catalog to page 6
Linear actuator CAHB series-7

CAHB series Dimensional drawing Basic configuration and optional 2-Hall encoder 42 9 Legend: 20,5 RL = retracted length ptional 2-Hall encoder has a 6-wires cable O Cable length L ±30 Stroke S 12 Front / Rear attachment Rod end with hole (A) Rod end with hole (B) Fork head with hole, (C) Retracted length calculation (RL) Stroke [mm] Retracted length (RL) with Rod end (Front) + Rod end (Rear) Retracted length (RL) with Rod end (Front) + Fork head (Rear) Retracted length (RL) with Fork head (Front) + Rod end (Rear) Retracted length (RL) with Fork head (Front) + Fork head (Rear)

 Open the catalog to page 7
Linear actuator CAHB series-8

Dimensional drawing Optional potentiometer and absolut analogue Stroke S Legend: RL = retracted length Front / Rear attachment Rod end with hole (A) Rod end with hole (B) Fork head with hole, (C) Retracted length calculation (RL) Stroke [mm] Retracted length (RL) with Rod end (Front) + Rod end (Rear) Retracted length (RL) with Rod end (Front) + Fork head (Rear) Retracted length (RL) with Fork head (Front) + Rod end (Rear) Retracted length (RL) with Fork head (Front) + Fork head (Rear)

 Open the catalog to page 8
Linear actuator CAHB series-9

CAHB series Performance diagrams Speed-load diagram Speed [mm/s] Current-load diagram Nominal current [A] 12 V DC Encoder resolution Type Potentiometer resolution Stroke [mm] Minimum resistence value of potentiometer Potentiometer resolution Absolute analog output Stroke [mm] Initial value VS RL position (V) Resolution (mm) Position feedback change (V/mm) Attachment orientation (refer to ordering key Attachment orientation) 90°

 Open the catalog to page 9
Linear actuator CAHB series-10

Connecting diagram Connecting diagram Red Black Yellow White Extension Retraction Limit switches Limit switches 2-Hall encoder signal Absolute analog output 12/24 V DC + 5V Output GND Black Limit switches 0Ω Retracted Extended Potentiometer Extension Limit switches GND Si + 5V Protection circuit Si + Absolute analog position sen

 Open the catalog to page 10
Linear actuator CAHB series-11

CAHB series Type Voltage A 12 V DC B 24 V DC Load 1 2 3 4 5 6 Design A TR12 screw X Customized 3 digital Stroke and 3 digital Retracted length (mm) Stroke Retracted length Base 1) with Front fork head with Rear fork head with Potentiometer or Absolute analog output C C A, P 050 158 +14 +7 +34 100 209 +14 +7 +34 150 260 +14 +7 +34 200 311 +14 +7 +34 250 362 +14 +7 +34 300 413 +14 +7 +34 1) Base: the Retracted length with front and rear attachment "Rod with hole", without "Potentiometer" and without "Absolute analog output" Ingress protection A Standard (IP 66s/69k) Front attachment A Rod with...

 Open the catalog to page 11
Linear actuator CAHB series-12

CAHB-20A Linear actuator Benefits • Compact design which has been tested for vigorous use • Robust and reliable • Thermal protection and virtually maintenance-free Features: • Integrated overload and thermal protection • Robust design • IP66 • Optional potentiometer and limit switches Technical data Designation Performance data Rated push force Rated pull force Holding force 1) Speed (full load to no load) Stroke Voltage Nominal current 12 V DC 24 V DC Duty cycle Ambient temperature Type of protection Weight (at 305 mm stroke) Color The holding force is the highest load a powered-down actuator...

 Open the catalog to page 12
Linear actuator CAHB series-13

CAHB series Dimensional drawing Basic configuration (dashed line for optional limit switch) 24,5 Ferrite Bead (for 12 V DC only) Attachment orientation (see page 14) Without limit swicth: RED (+) & BLACK (–) = retraction RED (–) & BLACK (+) = extension With limit switch: RED (+) & BLACK (–) = extension RED (–) & BLACK (+) = retraction 55 = dimension with limit switch Legend: RL = retracted length Retracted length calculation (RL) With limit switch 1) Without limit switch 2) Performance diagrams Speed-load diagram Current-load diagram

 Open the catalog to page 13
Linear actuator CAHB series-14

Dimensional drawing Optional potentiometer (dashed line for optional limit switch) 24,5 76 Ferrite Bead (for 12 V DC only) 600±30 With limit switch: RED (+) & BLACK (–) = extension RED (–) & BLACK (+) = retraction Without limit swicth: RED (+) & BLACK (–) = retraction RED (–) & BLACK (+) = extension 55 = dimension with limit switch Legend: RL = retracted length Retracted length calculation (RL) With limit switch 1) Without limit switch 2) Potentiometer resolution Stroke [mm] Electrical diagrams (refer to ordering key Attachment orientation) Ferrite Bead (for 12 V DC only) Green (Red) Brown (Black)...

 Open the catalog to page 14
Linear actuator CAHB series-15

CAHB series Type Voltage A 12 V DC B 24 V DC Load 1 2 Base: the Retracted length without "Limit switch", without "Potentiometer" Ingress protection A Standard: IP66 Attachment diameter (Front and rear) A Standard (hole: Ø13,1 mm) X Customized Attachment orientation (Front and rear) A Standard (0°) B 30° C 60° D 90° E 120° F 150° X Customized Option 1 0 None L Limit switch (only for load version 2 500 N) Option 2 0 None P Potentiometer Option 3 0 None T Thermal protection Customization The actuators have protection Clutch and E