Equinoxe Reverse
8Pages

{{requestButtons}}

Catalog excerpts

Equinoxe Reverse - 1

Equinoxe® Reverse ANATOMICAL. REDEFINED.

Open the catalog to page 1
Equinoxe Reverse - 2

...and no sacrifice of glenoid fixation or stability.2 Reported Scapular Notching Rate for Grammont-Style Reverse Shoulder Prosthesis 68.2% Scapular Notching Rate Grammont-Style Prosthesis, weighted average of 8 studies, n=8684 Equinoxe Reverse, 7 site multicenter study, n=2261

Open the catalog to page 2
Equinoxe Reverse - 3

Minimized Scapular Notching Lateralized Humeral Components • The three larger diameter glenospheres (38, 42 and 46mm) lateralize the humerus (without lateralizing the center of rotation) and increase joint stability.3,4 • Decreasing the humeral neck angle to 145 degrees further lateralizes the humerus (without lateralizing the center of rotation) and helps restore anatomic tensioning of the remaining intact rotator cuff.3,4 Additionally, placing the humeral tray on top of the resection eliminates the need to conically ream the proximal humerus, improves exposure and allows for larger...

Open the catalog to page 3
Equinoxe Reverse - 4

Structural Integrity. Even in the Most Challenging Conditions.

Open the catalog to page 4
Equinoxe Reverse - 5

Enhanced Glenoid Fixation Minimized Torque on the Glenoid • The larger diameter glenospheres result in a medialized center of rotation, thereby minimizing the torque on the glenoid. This medialized center of rotation has a long history of clinical success.5 • The curved back of the glenoid baseplate also allows for fixation by converting destabilizing shear forces into stabilizing compressive forces. Strong Initial Fixation • Strong initial fixation can be achieved with the press-fit bone cage of Stable Construct the glenoid baseplate, while the six-hole baseplate design provides up to 30...

Open the catalog to page 5
Equinoxe Reverse - 6

PLATFORM SHOULDER SYSTEM

Open the catalog to page 6
Equinoxe Reverse - 7

Seamlessly Integrated System Standardized Humeral Preparation • The Equinoxe’s platform system enables a surgeon to convert from a total shoulder to a reverse without humeral stem removal. • Using the same humeral stem, humeral instrumentation and humeral osteotomy for both indications standardizes the procedure and empowers the surgeon to intra-operatively decide ‘primary vs. reverse’. Standardized Glenoid Preparation • The offset bone cage of the glenoid baseplate is sized and positioned to be placed in the center of the glenoid to fill a central bone defect while distally shifting the...

Open the catalog to page 7
Equinoxe Reverse - 8

References 1. oche C, Wright T, Flurin PH, Grey S, Jones R, R Routman H, Gilot G, Zuckerman JD. Scapular notching radiographic analysis: recommendations for glenoid plate positioning and glenosphere overhang in male and female patients. Transactions of the 58th Annual Meeting of the Orthopaedic Research Society; 2012 Feb 4-7; San Francisco, CA. 2. lurin P et al. A correlation of five commonly used clinical F , metrics to measure outcomes in shoulder arthroplasty. Poster presentation at the 58th Annual Meeting of the Orthopaedic Research Society; 2012 Feb 4-7; San Francisco, CA. 3. oche C,...

Open the catalog to page 8

All Exactech catalogs and technical brochures

  1. AcuMatch

    7 Pages

  2. Biologics

    9 Pages

  3. Cemex_Main_

    12 Pages

  4. LBS II

    12 Pages

  5. EXACTECH HIP

    8 Pages

  6. Novation

    16 Pages

  7. Novation CFS

    2 Pages

  8. Spacer

    4 Pages

  9. accelerate

    3 Pages

  10. Element

    16 Pages