X-Ray Systems • Digital Imaging • Service Technical Specifications Page 1 of 3 Ceiling stand Minimum focus-ceiling distance 830 mmVertical telescope travel range 1800 mm Longitudinal travel range 3500 mm (optional: 5645 mm) Detent positions configurable during installation Transverse travel range 2150 mm (optional: 3500 mm) Detent positions configurable during installation Length of transverse track 3030 mm (optional 4380 mm) Tube rotation range, horizontal axis 120° / +120° Stitching option: -140° / +140° Tube rotation range, vertical axis -154°/ +182° Detent positions at: -90°; 0°; +90°; +180° Front touch user interface: SID Horizontal tube rotation angle Generator control Stitching option: Stitching control Motorized Movements Vertical movement of the telescope Stitching option: Tube rotation, horizontal axis (only in stitching mode) Stitching option: Vertical movement of the wall stand (only in stitching mode) Tracking Tube follows bucky of the wallstand Tube follows table height Stitching option: Tube rotation and vertical movement at the wall stand are coordinated (only in stiching mode). Changes in product illustrations or changes which serve the technical progress, as well as mistakes are reserved. Publisher: EXAMION GmbH, Erich-Herion-Str. 37, 70736 Fellbach, Germany.

 Open the catalog to page 1
X-DRS Ceiling Standard-2

EXAMION X-Ray Systems • Digital Imaging • Service Table height (motorized adjustment) 54 cm to 93 cm ± 1.5 cm (21.3'' to 36.6'' ± 0.6'') Tabletop travel Longitudinal: ± 48 cm (± 18.9''); Transverse: ± 14 cm (± 5.5'') Patient weight 280 kg in standard positions (patient in lying position or sitting in the middle of the table), 200 kg in other positions Vertical movement 34 cm to 173 cm (13.4" to 68.1") above floor (center to center) Stitching option: 37 cm to 173 cm (14.6" to 68.1") above floor (center to center) Tilting Bucky Tiltable from -20° to +90° with 0°/90° detent Time range 1 ms to 5...

 Open the catalog to page 2
X-DRS Ceiling Standard-3

Selectable Detectors Pixel Size Pixel Matrix Weight Protection Class Uniform Load Local Load EXAMION X-AQS DICOM Modality SCU EXAMION X-AQS PACS • Integrated Mini-PACS Changes in product illustrations or changes which serve the technical progress, as well as mistakes are reserved. Publisher: EXAMION GmbH, Erich-Herion-Str. 37, 70736 Fellbach, Germany.

 Open the catalog to page 3

All Examion catalogs and technical brochures

  1. X-CR HUM

    4  Pages

  2. X-XR VET

    6  Pages

  3. X-AI

    4  Pages

  4. X-AQS VET

    5  Pages

  5. X-DR M WiFi

    1  Page

  6. X-DRS Mobile

    6  Pages

  7. X-Dental

    5  Pages

  8. X-AQS HUM

    5  Pages

  9. X-DR L WiFi

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.