Technical Specifications
  • Tube Stand: SID range from 110 cm to 200 cm, height of 217 cm, vertical travel with electromagnetic brakes from 35 cm to 168 cm. Cross arm rotatable from -45° to +135°, Bucky unit rotatable from -90° to +90°, and Tube unit rotatable from -45° to 225°. Total weight approximately 280 kg including tube, collimator, bucky, and base plate. Complies with CE 2460 standards.
  • Generator: CPI CMP 200 DR, 50 kW, maximum 630 mA, maximum 150 kV, with AEC and hand switch. Operates on 3 phases / N / PE, 400 V, including console. Other generators available upon request.
  • Tube: Varex RAD-14 with focal spots of 0.6 / 1.2 mm, 300 kHu, maximum 150 kV, includes high voltage cable, weighing 17.4 kg. Optional models include RAD 21 and RAD 60.
  • Collimator: Manually turnable with LED lamp, integrated timer, and laser alignment.
  • AEC: 3-field measuring chamber with cable.
  • DAP (optional): DAP measuring device or calculation with automatic integration into X-AQS X-ray journal.
Detector Specifications
  • Selectable Detectors: X-DR L WiFi, X-DR L WiFi Premium, X-DR XL WiFi, X-DR XL WiFi Premium.
  • Pixel Size: Ranges from 100 µm to 150 µm.
  • Pixel Matrix: Varies from 2,304 px x 2,800 px to 4,267 px x 4,276 px.
  • Weight: Detectors weigh between 2.8 kg and 4.6 kg.
  • Protection Class: IPX1 and IP56.
  • Uniform Load: Supports between 100 kg and 300 kg.
  • Local Load: Supports 100 kg to 150 kg with a 4 cm diameter.
Software Configurations
  • EXAMION X-AQS: Includes DICOM Modality SCU, DICOM Worklist SCU, and DICOM Store SCU.
  • EXAMION X-AQS PACS: Features an integrated Mini-PACS.
See more

Catalog excerpts

X-DRS Floor U-Arm Manual-1

X-Ray Systems ■ Digital Imaging • Service Floor U-Arm ManualTechnical Specifications Tube Stand Vertical Travel (electromagnetic brakes) Bucky unit Tube unit Weight Regulatory requirements and standards rotable - 45° to + 135°, inclined exposures possible, electromagnetic brakes approx. 280 kg, incl. tube, collimator, bucky and base plate CE 2460 hand switch, 3 phases / N / PE, 400 V, incl. console Other generators on request Tube Varex RAD-14, focal spots 0.6 / 1.2 mm, 300 kHu, max. 150 kV, incl. high voltage cable, weight 17.4 kg (38.4 lbs) Collimator Manually turnable, LED lamp, integrated timer, laser alignment AEC 3-field measuring chamber with cable DAP (optional) DAP measuring device or DAP calculation, automatic integration into X-AQS X-ray journal Changes in product illustrations or changes which serve the technical progress, as well as mistakes are reserved. Publisher: EXAMION GmbH, Erich-Herion-Str. 37, 70736 Fellbach, Germany.

 Open the catalog to page 1
X-DRS Floor U-Arm Manual-2

Selectable Detectors Pixel Size Pixel Matrix Weight Protection Class Uniform Load Local Load EXAMION X-AQS DICOM Modality SCU EXAMION X-AQS PACS • Integrated Mini-PACS Changes in product illustrations or changes which serve the technical progress, as well as mistakes are reserved. Publisher: EXAMION GmbH, Erich-Herion-Str. 37, 70736 Fellbach, Germany.

 Open the catalog to page 2

All Examion catalogs and technical brochures

  1. X-CR HUM

    4  Pages

  2. X-XR VET

    6  Pages

  3. X-AI

    4  Pages

  4. X-AQS VET

    5  Pages

  5. X-DR M WiFi

    1  Page

  6. X-DRS Mobile

    6  Pages

  7. X-Dental

    5  Pages

  8. X-AQS HUM

    5  Pages

  9. X-DR L WiFi

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.