Overview: Excellentcare Medical (Huizhou) Ltd. provides a range of breathing system circuits designed for use with ventilators and humidifiers. These systems are engineered to minimize condensation, enhance humidity delivery, and reduce false alarms in medical settings.
Specifications:
  • Heated Wire Breathing Systems: These circuits are designed to minimize condensation, provide high humidity levels to patients, and reduce ventilator false alarms. They are available in various configurations for adults, pediatrics, and infants, with options for single or double heated wires and different limb lengths.
  • Breathing Systems with Water Traps: These systems feature high toughness PE tubes for accurate tidal volume calculation, detachable components for aerosol therapy, and a design that reduces flow resistance. They are available for adults, pediatrics, and infants with specific limb lengths and water trap configurations.
Accessories: The systems include temperature and pressure monitoring ports, and are packaged in boxes of 10 units each.
Key Features:
  • High humidity delivery to improve airway humidification.
  • Designs that reduce nursing workload and patient discomfort.
  • Compatibility with ventilators and humidifiers without heated wires.
  • Options for external aerosol therapy integration.
See more

Catalog excerpts

Breathing System Circuits-1

Breathing Systems Circuits EXCELLENTCARE MEDICAL (HUIZHOU) LTD. Add:Shatou Industrial Zone, Yuanzhou Town, Boluo County, Huizhou, 516123, Guangdong, China Tel:+86-752-6358333

 Open the catalog to page 1
Breathing System Circuits-2

Heated Wire Breathing Systems Used for ventilator and humidifier without heated wire. 1. Minimize the generation of condensation in the circuit, thereby reducing the incidence of coughing and the workload of nursing staff. 2. Maximum providing inhaled gas with a relative humidity of close to 100% to patients, so as to better humidify the patient's airway; 3. Reduce false alarms from ventilators due to splatters of condensate. Temperature and pressure monitoring port Adult breathing circuit, single heated wire, 1.6m, 0.8m limb Adult breathing circuit, single heated wire, 1.6m, humidifier chamber,...

 Open the catalog to page 2
Breathing System Circuits-3

Breathing Systems With Water Traps Classic high toughness PE tube, with good compliance and low expansibility, can calculate the tidal volume VT accurately. Detachable Y-piece and breathing tube, which can add external aerosol therapy and reduce waste of the nebulized medication. Inspiratory port and expiratory port of water trap are at a 120° angle to reduce resistance to flow. Temperature and pressure monitoring port Adult breathing circuit, 1.6m, 2 water traps, 0.4m limb Pediatric breathing circuit, 1.6m, 2 water traps, 0.8m limb Infant breathing circuit, 1.6m, 2 water traps, 0.3m limb