Section 12 - Sterilization
14Pages

{{requestButtons}}

Catalog excerpts

Section 12 - Sterilization - 1

STERILIZATION / STERILISATION ALL MEDICAL DEVICES ARE MANUFACTURED IN CONFORMITY WITH DIRECTIVE 93/42 CEE TOUS LES DISPOSITIFS MÉDICAUX SONT EN CONFORMITÉ AVEC LA DIRECTIVE 93/42 CEE

Open the catalog to page 1
Section 12 - Sterilization - 2

DRY HEAT STERILIZING UNIT SMALL DRY HEAT STERILIZING UNIT SMALL Outer case made of stainless steel. Inner structure, grid, removable perforated tray, hinged lid completely made of stainless steel. Inner structure and lid with nontoxic silicon rubber gasket, insulated by high grade glass wool. Stainless steel armoured heating element. Timer from 0 to 120 minutes, which disconnects the device at the end of the programmed time. Probe thermometer 0° - 200°C. Probe thermo-regulator 0° -200°C. Safety thermostat. Red pilot light shows the line insertion. Green pilot light points out the resistance...

Open the catalog to page 2
Section 12 - Sterilization - 3

DRY HEAT ELECTRIC STERILIZING UNIT FORCED HOT AIR GB DRY HEAT ELECTRIC STERILIZING UNIT FORCED HOT AIR Outer case and front completely made of stainless steel, included the drummed door strongly isolated with non-conducting material. Inner chamber entirely made of stainless steel, strongly strengthened, resistant to the heat and the corrosion at hot temperature. Inner stainless steel shelves adjustable in height. Door with lock and key. To guarantee the uniformity of the temperature in the heating room and to allow the circulation of the air, the device is provided with a ventilation motor...

Open the catalog to page 3
Section 12 - Sterilization - 4

DRY HEAT ELECTRONIC STERILIZING UNIT GB DRY HEAT ELECTRONIC STERILIZING UNIT Outer case made of stainless steel. Inner structure, two adjustable inner shelves and hinged door completely made of stainless steel. Inner structure and door with nontoxic silicon rubber gasket, insulated by high grade glass wool. Stainless steel armoured heating element. Lockable by key. Adjustable aeration tunnels, placed on the bottom of the right side and on the top of the left side for hot air adjustment and circulation, which is useful for a quick cooling of the device. Electronic running C.P.S. Use...

Open the catalog to page 4
Section 12 - Sterilization - 5

COMPARISON CHART CODE DESCRIPTIONS OVERALL DIMENSIONS DIMENSIONS EXTÉRIEURES A3211300, A3212400 DRY HEAT STERILIZING UNIT SMALL STERILISATEUR POUPINEL DRY HEAT ELECTRIC STERILIZING UNIT STERILISATEUR ELECTRIQUE A AIR CHAUD DRY HEAT ELECTRIC STERILIZING UNIT FORCED HOT AIR STERILISATEUR ELECTRIQUE A AIR CHAUD VENTILATION FORCEE DRY HEAT ELECTRONIC STERILIZING UNIT STERILISATEUR ELECTRONIQUE A AIR CHAUD INNER DIMENSIONS 300x125x80 h mm DIMENSIONS INTÉRIEURES 400x160x80 h mm CAPACITY / CAPACITÉ

Open the catalog to page 5
Section 12 - Sterilization - 6

RT41 STEAM AUTOCLAVE Pre-set, non-modificable cycles: all cycles are pre-set at the factory and guarantee perfect and safe sterilization of treated materials. There is no way the operator can manipulate or alter the cycles, and this safeguards against risks deriving from human error-Preset temperatures: the temperatures set for RT41 autoclave cycles are 134°C and 121°C. The 134°C cycles are normally used for the sterilization of solid and ferrous materials. 121°C cycles are normally used for sterilization of delicate materials-Operating cycles: RT41 is equipped to perform 2 sterilization...

Open the catalog to page 6
Section 12 - Sterilization - 7

RT42 GB STEAM AUTOCLAVE Pre-set, non-modificable cycles: all cycles are pre-set at the factory and guarantee perfect and safe sterilization of treated materials. There is no way the operator can manipulate or alter the cycles, and this safeguards against risks deriving from human error-Preset temperatures: the temperatures set for RT42 autoclave cycles are 134°C and 121°C. The 134°C cycles are normally used for the sterilization of solid and ferrous materials. 121°C cycles are normally used for sterilization of delicate materials-Operating cycles: RT42 is equipped to perform 2 sterilization...

Open the catalog to page 7
Section 12 - Sterilization - 8

RT91 STEAM AUTOCLAVE WITH PUMP RT91 is equipped with a powerful vacuum pump which, at the beginning of the cycle, expels any air pockets still present inside the chamber and, at the end of the sterilization phase, guarantees perfect drying of the materials treated. A sophisticated electronic system ensures constant monitoring of pressure, temperature and time. It can work also without the presence of the operator, as all the functions are automatic. RT91 has an electromagnetic block device on the door. The total automatism of each phase of the cycle safeguards against human error, even by...

Open the catalog to page 8
Section 12 - Sterilization - 9

RT45 STEAM AUTOCLAVE WITH PUMP RT45 is equipped with a powerful vacuum pump which, at the beginning of the cycle, expels any air pockets still present inside the chamber and, at the end of the sterilization phase, guarantees perfect drying of the materials treated. A sophisticated electronic system ensures constant monitoring of pressure, temperature and time. It can work also without the presence of the operator, as all the functions are automatic. RT45 has an electromagnetic block device on the door-The total automatism of each phase of the cycle safeguards against human error, even by...

Open the catalog to page 9
Section 12 - Sterilization - 10

RT92 FRACTIONAL VACUUM STEAM AUTOCLAVE Treated circular chamber made of AISI 304 stainless steel-Maximum load per cycle 5 kg.-3 safety devices on the door: electromagnetic, electrical, dynamicControls card installed in the board-Graphic display-Automatic barometric alignment system-Pump-operated water filling system with automatic stop when the tank is full-Door seal to ensure maximum duration-Rear board with prefittings and automatic water filling and discharge-Forced ventilation system incorporated in the equipment-Protected tray holder to safeguard against contact between load and...

Open the catalog to page 10
Section 12 - Sterilization - 11

RT90 FRACTIONAL VACUUM STEAM AUTOCLAVE Treated circular chamber made of AISI 304 stainless steel-Maximum load per cycle 5 kg.-3 safety devices on the door: electromagnetic, electrical, dynamicControls card installed in the board-Graphic display-Automatic barometric alignment system-Pump-operated water filling system with automatic stop when the tank is full-Door seal to ensure maximum duration-Rear board with prefittings and automatic water filling and discharge-Forced ventilation system incorporated in the equipment-Protected tray holder to safeguard against contact between load and...

Open the catalog to page 11