BALLOON CATHETERS - 1

Technical form BALLOON CATHETERS ISO Med manufactures 5 balloon catheters types: - Simple and double lumen embolectomy catheters: range 300000 and 500000, - Thrombectomy catheters: range 310000, - Occlusion catheters: range 320000, - Irrigation catheters: range 330000, - Simple and double lumen biliary catheters: range 340000 and 540000. - for sizes 2F to 5F: a Pebax® tube and Luer Lock hub for larger sizes and double lumen catheters: a polyurethane tube and a polyamide Luer Lock hub. EMBOLECTOMY CATHETERS: The distal portion of the catheter contains a latex section that inflates to form a balloon. For the double lumen catheters, the derivation branch (white) is connected to the balloon and the main branch (which colour indicates the catheter size) allows the injection of the necessary solutions. The catheter is marked in 10 cm graduation to gauge the length of insertion and, noted on the tube at the hub proximity, its naming, size and the maximal volume to inject in the balloon. The embolectomy catheter is indicated for the removal of fresh, soft emboli in the peripheral arterial system. The catheter is intended to be passed through an arteriotomy and advanced along the artery until the suspected occlusion site is reached. The simple and double lumen embolectomy catheters are composed of: SPECIFICATIONS Single lumen embolectomy catheters: CATHETER TUBE BALLOON SIZE (F) COLOUR CODE LENGTH (MM) DIAMETER (MM) LENGTH (MM) 300240 2 Grey 400 0.70 5 DIAMETER INFLATED (MM) 4 300260 2 Grey 600 0.70 5 4 300280 2 Grey 800 0.70 5 4 300340 3 Green 400 1.00 6 5 300360 3 Green 600 1.00 6 5 300380 3 Green 800 1.00 6 5 300440 4 Red 400 1.35 8 8 300460 4 Red 600 1.35 8 8 300480 4 Red 800 1.35 8 8 300540 5 White 400 1.70 12 10 300560 5 White 600 1.70 12 10 300580 5 White 800 1.70 12 10 300640 6 Blue 400 2.00 15 13 300660 6 Blue 600 2.00 15 13 300680 6 Blue 800 2.00 15 13 REFERENCE FT/3X&5X/A – Ind 4 – P 1/6

Open the catalog to page 1
BALLOON CATHETERS - 2

Technical form BALLOON CATHETERS CATHETER TUBE BALLOON SIZE (F) COLOUR CODE LENGTH (MM) DIAMETER (MM) LENGTH (MM) 300740 7 Yellow 400 2.35 16 DIAMETER INFLATED (MM) 14 300760 7 Yellow 600 2.35 16 14 300780 7 Yellow 800 2.35 16 14 300840 8 Brown 400 2.70 16.5 15 300860 8 Brown 600 2.70 16.5 15 300880 8 Brown 800 2.70 16.5 15 REFERENCE Double lumen embolectomy catheters: CATHETER TUBE BALLOON SIZE (F) COLOUR CODE LENGTH (MM) DIAMETER (MM) LENGTH (MM) 500440 4 Red 400 1.35 8 DIAMETER INFLATED (MM) 8 500460 4 Red 600 1.35 8 8 500480 4 Red 800 1.35 8 8 500540 5 White 400 1.70 12 10 500560 5...

Open the catalog to page 2
BALLOON CATHETERS - 3

Technical form BALLOON CATHETERS SPECIFICATIONS CATHETER TUBE BALLOON SIZE (F) COLOUR CODE LENGTH (MM) DIAMETER (MM) LENGTH (MM) 310640 6 Blue 400 2.00 14 DIAMETER INFLATED (MM) 12 310660 6 Blue 600 2.00 14 12 310680 6 Blue 800 2.00 14 12 310840 8 Brown 400 2.70 16 13 310860 8 Brown 600 2.70 16 13 310880 8 Brown 800 2.70 16 13 311040 10 Grey 400 3.35 18 19 311060 10 Grey 600 3.35 18 19 311080 10 Grey 800 3.35 18 19 REFERENCE OCCLUSION CATHETERS: The catheter is marked in 10 cm graduation to gauge the length of insertion and, noted on the tube at the hub proximity, its naming, size, and the...

Open the catalog to page 3
BALLOON CATHETERS - 4

Technical form BALLOON CATHETERS BILIARY CATHETERS: The biliary catheter is indicated for digestive surgery interventions to desobstruct biliary ducts in particular the choledoque. The simple and double lumen biliary catheters are composed of: - for sizes 2F to 5F: a Pebax® tube and Luer Lock hub - for larger sizes and double lumen catheters: a polyurethane tube and a polyamide Luer Lock hub. The catheter is marked in 1 cm graduation to gauge the length of insertion and, printed on the proximal end, its naming, size and the maximal volume to inject in the balloon. The distal portion of the...

Open the catalog to page 4
BALLOON CATHETERS - 5

Technical form BALLOON CATHETERS CATHETER TUBE BALLOON SIZE (F) COLOUR CODE LENGTH (MM) DIAMETER (MM) LENGTH (MM) 5 White 800 1.70 12 DIAMETER INFLATED (MM) 10 540640 6 Blue 400 2.00 15 13 540660 6 Blue 600 2.00 15 13 540680 6 Blue 800 2.00 15 13 540740 7 Yellow 400 2.35 16 14 540760 7 Yellow 600 2.35 16 14 540780 7 Yellow 800 2.35 16 14 5405200 5 White 2000 1.70 12 10 5407200 7 Yellow 2000 2.35 16 14 REFERENCE 540580 IRRIGATION CATHETERS: The catheter is marked in 1 cm graduation to gauge the length of insertion and noted on the tube at the hub proximity, their naming and size.The catheter...

Open the catalog to page 5
BALLOON CATHETERS - 6

Technical form BALLOON CATHETERS CATHETER REFERENCE TUBE 331040 10 COLOUR CODE Grey 331060 10 331080 10 SIZE (F) 400 DIAMETER (MM) 3.35 Grey 600 3.35 Grey 800 3.35 LENGTH (MM) PACKAGING ISO Med balloon catheters are packaged in double peel away sachets. These sachets are composed of: - the transparent upper sheet is made of PETP/PP. It permits a quick identification of the contents. It mentions the necessary indications of contents identification: designation, item code, manufacture date … - the opaque lower sheet is made of medical quality PGL that is very resistant and adapted to the...