1. Catalogs
  2. Fisher & Paykel Healthcare
  3. Evaqua 2? Infant Product Booklet
video corpo

Evaqua 2? Infant Product Booklet

Evaqua 2? Infant Product Booklet
1 / 10 PagesView full catalog

Evaqua 2? Infant Product Booklet

Product catalog summary
Introduction to Evaqua 2 Technology
Evaqua 2 is a groundbreaking breathing circuit technology that incorporates MicroCell Technology™. It allows water vapor to diffuse through the tubing wall, reducing the formation of liquid water and minimizing expiratory limb mobile condensate.
Key Benefits
  • Minimizes the need for clinician intervention to manage expiratory limb condensate.
  • Reduces ventilation issues such as auto-PEEP and ventilator dyssynchrony.
  • Eliminates the need for water traps and reduces condensate buildup in expiratory filters.
  • Alleviates ventilator alarm issues related to expiratory block condensate.
  • Promotes a maintenance-free, closed system, saving clinician time.
Features of Evaqua 2
  • Protection: Utilizes a robust MicroCell wall structure.
  • Humidity Transfer: Achieved through the Evaqua material.
  • Performance: Enhanced by a heater wire and spine construction.
Comparison with Conventional Circuits
Evaqua 2 allows humidity in the expiratory limb to diffuse through the circuit wall before condensing, unlike conventional circuits where condensate forms when humidity touches cooler surfaces.
MicroCell Technology Functionality
The Evaqua material is permeable to water vapor, allowing it to pass through the circuit wall while maintaining a gas seal and blocking pathogens.
Conclusion
Evaqua 2 represents a significant advancement in breathing circuit technology, offering numerous benefits in terms of maintenance, safety, and efficiency.
See more

Catalog excerpts

Evaqua 2? Infant Product Booklet-2

Evaqua 2 Features Evaqua 2. It’s a world first in breathing circuit technology that allows water vapor to diffuse through the tubing wall. Evaqua membrane technology clears humidity from the expiratory limb – minimizing the chance of it forming into liquid water. The Benefits are Clear... • Minimizes Expiratory Limb Mobile Condensate • Promotes a Maintenance-Free, Closed System

 Open the catalog to page 2
Evaqua 2? Infant Product Booklet-3

through a robust MicroCell wall structure.

 Open the catalog to page 3
Evaqua 2? Infant Product Booklet-4

Humidity Transfer takes place through Evaqua material.

 Open the catalog to page 4
Evaqua 2? Infant Product Booklet-5

is enhanced through a heater wire and spine construction.

 Open the catalog to page 5
Evaqua 2? Infant Product Booklet-6

Minimizes Expiratory Limb Mobile Condensate Evaqua 2 reduces issues caused by expiratory condensate. Infant EVAQUA  Breathing Circuits available 2 • educes the need for clinician intervention R to break open the expiratory limb • educes ventilation issues (auto-PEEP, R ventilator dyssynchrony) • No water traps to empty • Reduces condensate buildup in expiratory filters • lleviates ventilator alarm issues related to A expiratory block condensate • Saves clinician time Pictured: Infant Evaqua  Breathing Circuit 2

 Open the catalog to page 6
Evaqua 2? Infant Product Booklet-7

Promotes a Maintenance-Free, Closed System Evaqua 2 reduces the need for clinician intervention to break open the expiratory limb to remove condensate. • Reduces the risk of pathogen transfer to the patient or clinician • entilation can remain uninterrupted, maintaining V PEEP and promoting lung recruitment • Saves clinician time

 Open the catalog to page 7
Evaqua 2? Infant Product Booklet-8

Evaqua 2 Comparison Evaqua  allows the humidity in the expiratory 2 limb to freely diffuse through the wall of the breathing circuit before it has an opportunity to condense and form into liquid water. EVAQUA 2 With conventional circuits, condensate can form inside the expiratory limb or ventilator when humidity in the expiratory gas flow touches cooler surfaces along the gas path. conventional breathing circuits Water Vapor (Humidity) Water Vapor (Humidity) Colder Surface

 Open the catalog to page 8
Evaqua 2? Infant Product Booklet-9

How MicroCell Technology Works Humidity passes through the wall of the expiratory limb via Evaqua material that is permeable to water vapor. Due to the special nature of this material, water vapor can pass through the wall of the circuit while retaining a gas seal. Pathogens are also blocked as Evaqua is only permeable to water vapor. magnified view of evaqua 2 membrane Water vapor (humidity) Outside Circuit permeable Evaqua Protection through a robust MicroCell wall structure inside Circuit Water vapor (humidity)

 Open the catalog to page 9
Evaqua 2? Infant Product Booklet-10

185047125 Rev B © 2011 Fisher & Paykel Healthcare Limited For more information please contact your local Fisher & Paykel Healthcare representative

 Open the catalog to page 10

All Fisher & Paykel Healthcare catalogs and technical brochures

  1. Evaqua™ 2

    2  Pages

Archived catalogs

  1. HC150

    2  Pages

  2. OSA Catalogue

    70  Pages

  3. AIRVO 2

    2  Pages

  4. OSA Catalog

    25  Pages

  5. ThermoSmart™

    16  Pages

  6. F&P Neowrap

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.