1. Catalogs
  2. Fisioline
  3. LUMIX SURGERY DUAL DENTAL

LUMIX SURGERY DUAL DENTAL
1 /9Pages

LUMIX SURGERY DUAL DENTAL

LUMIX SURGERY DUAL DENTAL
1 /9Pages

Catalog excerpts

LUMIX SURGERY DUAL DENTAL-1

All in one laser Double your operation The Dental Laser with dual modality use for Surgery and Therapy biomedical instrumentation

 Open the catalog to page 1
LUMIX SURGERY DUAL DENTAL-2

LUMIX® SURGERY DUAL Dental is the latest Fisioline® innovation derived from over 40 years of scientific research, design and production made in Italy at the forefront of the latest generation Laser technologies. A unique technology, extremely performing and effective in achieving surgical and therapeutic goals in short time. The emitted energy is almost totally absorbed by hemoglobin, so it is particularly recommended as coagulant and antiedematous. At this wavelength, melanin optimally absorbs the laser energy, ensuring a high dose of energy on the surface region, encouraging the anti-edema...

 Open the catalog to page 2
LUMIX SURGERY DUAL DENTAL-3

Surgical Mode 1 SINGLE TOOL 2 ACTIONS Surgery without blade Using the contact mode fiber, LUMIX® SURGERY DUAL Dental is the evolution of the common blade, with unique particulars like biostimulation and analgesia. THE DISTINTIVE FEATURES OF LUMIX® SURGERY DUAL DENTAL APPLIED TO SURGERY MAXIMUM PRECISION IN CUTTING SOFT TISSUES ESSENTIAL FOR MICROSURGERY: AVOIDS THE NEED OF STITCHES COAGULATION ABILITY LESS IMPACT ON TREATED AND SURROUNDINGS TISSUES LESS POST-SURGERY PAIN MAIN ADVANTAGES COMPARED TO TRADITIONAL SURGICAL METHODS LESS POST-SURGERY EDEMA NO TRACTION OF THE TISSUES IN THE HEALING...

 Open the catalog to page 3
LUMIX SURGERY DUAL DENTAL-4

Therapeutic Mode C.P.S.® CONTINUOUS, PULSED AND SUPERPULSED LASER SYSTEM LUMIX® SURGERY DUAL Dental is an innovative high power multidiode laser with C.P.S.® (Continuous, Pulsed and Superpulsed) emission that performs effective photobiostimulation in the Dental field. The multiwavelength of LUMIX® SURGERY DUAL Dental , the high peak power (400W) and the high average power that reaches 31W allow for a large volumetric treatmets with high amount of energy deep into tissues. Wavelength and peak power are among the essential factors for deep tissue penetration. It is important that the laser have...

 Open the catalog to page 4
LUMIX SURGERY DUAL DENTAL-5

THERAPEUTIC indications POST ORAL SURGERY GINGIVECTOMY: Surgical removal of the gingival tissue to create a new gingival margin. The laser favours cicatrization, vaporises the tissue and leaves the operating field bloodless. GINGIVOPLASTY: Remodelling of gums and restoration of physiologic gingival morphology. The gingival profile can be modelled with the laser. FRENECTOMY AND OPERCULECTOMY The laser reduces the inflammatory and infectious components of perimplantitis. It speeds osseointegration times in both dental implants and in operations (consolidation of biomaterials) for bone regeneration...

 Open the catalog to page 5
LUMIX SURGERY DUAL DENTAL-6

Effect of superpulsed laser irradiation on bone formation in a human osteoblast-like cell line, MINERVA STOMATOLOGICA 2007; 56;: 27-30 G. Martinasso, M. Mozzati, R. Pol, R.A. Canuto, G. Muzio - Department of Medicine and Experimental Oncology Turin University, Turin, Italy. The low level laser therapy in the management of neurological burning mouth syndrome. A pilot study. Umberto Romeo, DDS1, Alessandro Del Vecchio, DDS, Mauro Capocci, DDS1, Claudia Maggiore, MD, DDS2, Maurizio Ripari, MD, DDS1 - “Sapienza” University of Rome, Rome, Italy. Studio preliminare, il laser nel trattamento di lesioni...

 Open the catalog to page 6
LUMIX SURGERY DUAL DENTAL-7

The high Fisioline technology in a dynamic, compact and portable laser ® Colour touch-screen display with simple, intuitive interface Handpiece with surgical optical fiber 200 - 320 - 400 - 600 micron Safety pedal Therapeutic handpiece with interchangeable terminal Bluetooth Pedal (Optional) Adjustable Stripper and Fiber Cutter Fiber Terminal Interchangeable Tips Device carrying bag (Optional) Therapeutic handpiece with adjustable focal Laser safety goggles USB port for software upgrade Lensholder terminal and spacers for aesthetic medicine Trolley model “Dinamico” (Optional) 12

 Open the catalog to page 7
LUMIX SURGERY DUAL DENTAL-8

electromedical equipment Class I type BF device for laser surgery and laser therapy IIb (Dir. 93/42/EEC, as amended by Directive 2007/47/EC) 100-240V single phase (external power supply) 50/60Hz Class 4 continuous, burst mode with adjustable action time TOn from 0,5ms to 100ms; TOff from 0,5ms to 300ms continuous, pulsed, superpulsed and C.P.S.® 70ns 0-100.000 Hz 1sec - 99 min with digital display real visualization of the area interested from the IR beam wide 7’’ TFT color touch screen display according to the preset parameters end of treatment laser source activation automatic SMA connector...

 Open the catalog to page 8
LUMIX SURGERY DUAL DENTAL-9

Borgata Molino, 29 12060 VERDUNO (CN) • ITALY Tel.: +39.0172.470432-0172.470433 [email protected] www.fisioline.com As the tecnology is being constantly updates as well as our production systems, the technical features and sizes of the appliances described above are subject to modifications.

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.