Excellence in External Fixation EXAMPLE PLACEMENTS - TRAUMA NOTE FIXATOR PLACEMENTS DEPICTED IN THIS DOCUMENT ARE SUGGESTIONS ONLY OTHER PLACEMENTS/ASSEMBLIES OF THE MODULAR FRAMES MIGHT BE APPLICABLE NO RIGHTS CAN BE DERIVED OF THIS DOCUMENT. VERSION: MAY 2023 TRAUMA
Open the catalog to page 1FIXUS22 FIXUS22 DYNAMIC COUPLING FIXUS22 STANDARD FIXUS22 CD COMPRESSION DISTRACTION ACCESSORIES (CONTACT YOUR DISTRIBUTOR) INDICATIONS: • FINGER JOINT STABILISATION, WITH EARLY MOBILISATION • METACARPAL FRACTURES • METATARSAL FRACTURES • PHALANGEAL FRACTURES • LENGTENING • OPEN FRACTURES • COMPLEX SOFT TISSUE INFECTIONS • SMALL JOINT ARTHRODESIS • HAND CONTRACTURES EXAMPLE PLACEMENTS - TRA
Open the catalog to page 2FIXUS22 - DYNAMIC COUPLING EARLY JOINT MOBILIZATION EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 3FIXUS22 - STANDARD BRIGDING NON BRIDGING EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 4EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 5FIXUS22 - HAND FIXUS22 - CD COMPRESS OR DISTRACT JOINT EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 6FIXUS33 FIXUS33 DYNAMIC COUPLING FIXUS33 STANDARD FIXUS33 T-CLAMP ACCESSORIES (CONTACT YOUR DISTRIBUTOR) INDICATIONS: • WRIST STABILISATION, WITH EARLY MOBILISATION JOINT • WRIST REDUCTION • (DISTAL) RADIUS FRACTURES • ULNA FRACTURES • PROXIMAL HUMERUS • CALCANEUS FRACTURES • PEDIATRICS • OPEN FRACTURES EXAMPLE PLACEMENTS - TRAUM
Open the catalog to page 7FIXUS33 - WRIST FIXUS33 - DYNAMIC COUPLING EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 8FIXUS33 - WRIST REDUCTION CAN BE PERFORMED WITH: FIXUS33 DYNAMIC COUPLING FIXUS33 STANDARD EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 9FIXUS33 - STANARD WITH CD UNIIT COMPRESS OR DISTRACT JOINT EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 10FIXUS33 - STANARD SHOWN: BI PLANAR PIN PLACEMENT EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 11EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 12EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 13FIXUS33 - T CLAMP SHOWN WITH BI PLANAR PIN PLACEMENT DISTALLY EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 14FIXUS33 -STANDARD SHOWN WITH FULL BI PLANAR PIN PLACEMENT MULTIPLE OPTIONS: MONO FOCAL AND BI FOCAL EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 15FIXUS66 ELBOW FIXUS66 DEVICE ACCESSORIES (CONTACT YOUR DISTRIBUTOR) INDICATIONS: • INTRA-ARTICULAR FRACTURES • POST-TRAUMATIC STIFFNESS • DELAYED TREATMENT OF DISLOCATED AND RIGID ELBOWS • PERSISTENT JOINT INSTABILITY • UNSTABLE ELBOW FRACTURES • DISTAL HUMERUS FRACTURES EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 16FIXUS66 ELBOW DEVICE FLEXIBLE PIN PLACEMENT AND/ OR MULTIPLE BASES EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 17FIXUS66 ELBOW DEVICE WITH MULTIPLE BASES IN HUMERUS (SHOWN WITH BI PLANAR PIN PLACEMENT IN HUMERUS) EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 18FIXUS66 ELBOW DEVICE CD-UNIT: COMPRESS OR DISTRACT JOINT (SHOWN WITH BI PLANAR PIN PLACEMENT IN HUMERUS) EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 19FIXUS66 ELBOW DEVICE INTERCHANGEABLE ROD FOR EXTRA SHORT ASSEMBLY EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 20EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 21FIXUS66 TRAUMA FIXUS66 ACCESSORIES (CONTACT YOUR DISTRIBUTOR) INDICATIONS: • COMPLEX UPPER AND LOWER EXTREMITY FRACTURES • FRACTURES WITH POLYTRAUMA • PEDIATRIC AND ADULT FRACTURES • TEMPORARY JOINT BRIDGING • FRACTURE STABILIZATION (TRAUMA UNTILL FINAL TREATMENT) EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 22FIXUS66 SHOWN IN BI-PLANAR PIN PLACMENT EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 23FIXUS66 SHOWN IN BI-PLANAR PIN PLACMENT EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 24FIXUS66 COMBINED WITH F55 HYBRID SYSTEM EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 25FIXUS66 COMBINED WITH F55 HYBRID SYSTEM EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 26FIXUS66 COMBINED WITH F55 HYBRID SYSTEM EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 27FIXUS66 WITH CD UNIT COMPRESS FRACTURE EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 28BIFOCAL FIXUS66 MULTIPLE FRAGMENTS EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 29FIXUS66 SHOWN IN BI-PLANAR PIN PLACMENT EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 30FIXUS66 COMBINED WITH F55 HYBRID SYSTEM EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 31FIXUS66 WITH CD UNIT, AND SINGLE PINHOLDER FOR JOINT DISTRACTION (OR FUSION) EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 32FIXUS66 WITH CD UNIT, COMBINED WITH F55 HYBRID SYSTEM FOR JOINT DISTRACTION (OR FUSION) EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 33FIXUS66 LP EQUIPED WITH 2 SINGLE PINHOLDERS IN THE CALCANEUS OFFERS JOINT ARTICULATION EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 34FIXUS66 LP WITH CD UNIT, COMBINED WITH FOR JOINT DISTRACTION (OR FUSION) EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 35EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 36EXAMPLE PLACEMENTS - TRAUMA
Open the catalog to page 37Excellence in External Fixation FIXUS BV Spoorstraat 9 7261 AE, Ruurlo The Netherlands
Open the catalog to page 3818 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages