Accessories for STRA Room Controller. Accessories STRA-01, STRA-04 and STRA-14 External temperature sensor Technical data room sensor: - Temperature range - Sensor element - Protection class Technical data external sensor: - Temperature range - Sensor element - Protection class Technical data clamp-on sensor: - Temperature range - Time constant - Sensor element - Protection class - Cable length Technical data duct sensor with housing: - Temperature range - Time constant - Sensor element - Protection class - Ø sensor - Length insertion Technical data duct sensor with cable: - Temperature range - Time constant - Sensor element - Protection class - Ø sensor - Length insertion Occupancy detector Technical data wall or ceiling mounted : - Supply voltage - Power consumption - Ouput - Detection range - Temperature range - Protection class Technical data ceiling mounted : - Supply voltage - Power consumption - Ouput - Detection range - Temperature range - Protection class Fläkt Woods 24±2 V AC/DC 5 mA @24 V AC 200 mA, 24 V AC/DC, potential-free change-over relay 15 x 15 m at 110° angle -20…+50°C IP20 24±2 V AC/DC 15 mA @24 V AC 200 mA, 24 V AC/DC, potential-free change-over relay Mounting height x 2,5 = diameter converage, 25° angle -20…+50°C IP20 Specifications are subject of alteration without further notice.
Open the catalog to page 1Accessories for STRA Room Controller. Condensation detector Technical: - Material detector element - Cable water resistant, flexible PCB, self-adhesive 2 x 0,25 mm², length 1 m Technical data wall mounted: - Power supply - Power consumption - Ambient temperature - Ambient humidity - Temperature dependance - Response time - Warm-up time - Protection class - Working range - Accuracy - Output: Window contact,magnetic contact (white) 24 V AC±15%, 50…60 Hz or 15…35 V DC 3W -5…+55°C 0…90%RH, non-condensating typ. 2 ppm CO2/°C <90 s <5 min IP30 0…2000 ppm <±(50 ppm + 2% of measuring...
Open the catalog to page 2Accessories for STRA Room Controller. Valve and actuator Siemens Technical data: - For direct mounting with union nut (no tools required] -Two-wire connection - Position indication - Positioning time - Mounting postion - Operation effect - Positioning force 230 V operating voltage, 2-position control signal AC/DC 24 V operating voltage, 2postion control signal or PDM Description, valve Lift height Flakt Woods Specifications are subject of alteration without further notice.
Open the catalog to page 3Accessories for STRA Room Controller. Valve and actuator Broen Actuator Technical data: AC AC/DC Operating power Closing and opening time Actuating force Ambient temperature Pretection class Connection cable 230 V operating voltage, 2-position control signal 24 V operating voltage, 2postion control signal or PDM O1.8W 3 minutes 100N ±5% 0-60 °C IP 54 1m Valve The valve is delivered with push-on connections (inlet and outlet) or with push-on connection on inlet and smooth end on outlet. Thus it offers very fast connections on site to save time and reliable connection without leakages,The...
Open the catalog to page 4Accessories for STRA Room Controller. Product code Accessories External temperature sensor 1 = Room temperature sensor 2 = Out door temperature sensor 4 = Duct sensor with housing 5 = Duct sensor with cable 1,5 m 6 = Duct sensor with cable 3 m Window contact Flakt Woods Specifications are subject of alteration without further notice.
Open the catalog to page 5Accessories for STRA Room Controller. Product code Actuator and Valve Siemens 01=DN-15 (kvs 0.25-1.9) female 1/2" valve inlet 02=DN-20 (kvs 0.25-2.6) female3/4" valve inlet 03=DN-25 (kvs 0.25-2.6) female 1" valve inlet 11=DN-15 (kvs 0.25-1.9) Compression ring valve inlet 21=DN-15 (kvs 0.25-1.9) Push on valve inlet Valve actuator(cc) 00=Without 01 =24 V NC cable 1m 11 =24 V N0 cablel 1m 21 =230 V NC cable 1m 31 =230 V N0 cable 1m Adapter Siemens actuator Type of adapter (cc) 0= Special 53= Danfoss RA-N (RA2000) 54 = Danfoss RAVL 55 = Danfoss RAV 60 = TA-RVT 61 = Markaryd Broen Valve(bb)...
Open the catalog to page 6Accessories for STRA Room Controller. 090 = 900 mm Connection type 1 (ccc) 010 = Pipe end Ø 15 019 = John Guest push on Connetion type 2 (ddd) 019 = John Guest push on Fläkt Woods Specifications are subject of alteration without further notice.
Open the catalog to page 7All Fläkt Woods Group catalogs and technical brochures
-
HyPower-Geko
16 Pages
-
vQ STREAM
16 Pages
-
ATpicco
12 Pages
-
ReCOOLER HP
16 Pages
-
Ecodesign
8 Pages
-
diffuser range
8 Pages
-
ECONET ® PREMIUM
7 Pages
-
SEMCO
8 Pages
-
eQ ™ Air
202 Pages
-
EUMM Air conditioning unit Catalogue
245 Pages
-
Cooler and ReCooler
5 Pages
-
LVD Unit Heater, TEMPER
44 Pages
-
ATD Unit Heater
56 Pages
-
ControlMaster
4 Pages
-
Chilled beam Flexicool® IQID
5 Pages
-
Chilled beam Flexicool® IQIC
2 Pages
-
IPSUM Optimization System
16 Pages
-
Chilled beam iQ Star WEGA
13 Pages
-
Chilled Beam IQ Star STELLA
9 Pages
-
RoomMaster ABR unit
16 Pages
-
Air Handling Unit EU
203 Pages
-
Supply air unit VEKA
4 Pages
-
TapMaster Air Handling Unit
16 Pages
-
eQ Energy Solutions
4 Pages