Catalog excerpts
Air Handling Unit EU Technical Data 2010
Open the catalog to page 1Modular units EU Flow Chart Detailed table of contents ..…………………………………………….1 - 4 Unit Description ………………………………………………………5 - 63 Pressure drop Tables ……………………………………………….64 - 80 Fan Chart …...……………………………………………………….81 - 99 Description Texts …..………………………………………………100 - 110 Flow Chart
Open the catalog to page 2TECHNICAL DATA - 2008 page 1 Contents Contents – N0 . . . . . . . . . . . . . .Page EU Catalogue– 8007 Contents – Pressure drop . . . . . . . . . . . . . . . . . . . .64 Unit Descriptions Air heaters/Air coolers – 8010 . . . . . . . . . . . . . . .12 Humidifiers/ Centrifugal fans/ Angle Section/ Empty Section/ Silencer – 8010 .14 Dimensions – Quick Selection – 8012 . . . . . . . . . .20 Quick Selection Tables – 8006 . . . . . . . . . . . . . . .21 Quick Selection Tables for Air Coolers – 8013 . . .24 ControlMaster – 8612 . . . . . . . . . . . . . . . . . . . . . . .29 Description, General ....
Open the catalog to page 3TECHNICAL DATA - 2008 page 2 Contents Descriptive Texts – 8015 Unit Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101 Outdoor version . . . . . . . . . . . . . . . . . . . . . . . . . .102 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103 Duct Connections . . . . . . . . . . . . . . . . . . . . . . . . .103 Filter Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . .104 Unit casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112 Stacked units . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 Inspection door...
Open the catalog to page 4TECHNICAL DATA - 2008 page 3 Contents Evaporative humidifier EUQA . . . . . . . . . . . . .148 Silencer EUSA . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Frost protection screen EUTE . . . . . . . . . . . . . . .151 Rotary heat exchanger EURF – ECOTERM . . . . . . . . . . . . . . . . . . . . . . .153 Liquid-coupled heat exchanger EURT – ECONET . . . . . . . . . . . . . . . . . . . . . . . . .157 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158 Air handling unit, Casing EUBB EUBS Casing, outdoor version, sizes 60-84 . . . . . . . . . . . . . . . .161...
Open the catalog to page 5TECHNICAL DATA - 2008 page 4 Contents Plenum fan EULK Humidifiers EUQA Silencers EUSA Casing sections EUTC EUTZ EUEL Heat exchangers Replacement panel, AHU., fans, heat exchange, Empty section accessories . . .193 Electrical cabinet section . . . .193 ECOTERM, liquid-coupled REGOTERM rotary heat EURA EURZ REGOTERM accessories . . . .194 heat exchangers . . . . . . . . . . .195 ECONET, liquid-coupled heat exchangers, external energi .195
Open the catalog to page 6TECHNICAL DATA - 2008 page 5 Design Frame members: Specially designed, enclosed frame members, made of 1.5 mm thick or 1.8 mm thick (for unit sizes 60–84) sheet steel, available in aluminiumzinc plated or stainless version. Corner pieces: Rounded corner pieces cast in one piece, with two tapped holes in each leg. The frame members and corner pieces are joined together by means of screws. Panels: Closed, double-skin sheet steel with 50 mm thick insulation sandwiched between the sheet steel. The skin consists of 0.7 or 1.0 mm thick galvanized or stainless sheet steel. Incombustible 50 kg/m3...
Open the catalog to page 7TECHNICAL DATA - 2008 page 6 Casing – design and properties The casing framework consists of box-section frame members joined together sturdy corner pieces. The entire arrangement forms a strong and stable framework. The panels and inspection doors are of double-skin construction, with 50 mm thick mineral wool insulation sandwiched between sheet steel. The panels can be removed from the unit. In all unit sizes, the inspection doors are hung on adjustable hinges and are equipped with mechanically secured sealing strips. The inspection doors are also available with door locks. The sandwich...
Open the catalog to page 8TECHNICAL DATA - 2008 page 7 Casing – design and properties Doors are fitted with durable rubber seals and are mounted on hinges. Samtliga dörrar förses med låsbara handtag. The insulation factor kb (dimensionless, cold bridge factor) is defined by the following formula: kb = (ts - ti) / (te - ti) where Anti-condensation insulation of the casing ti = Average temperature of the air in the unit casing te = Average ambient temperature Heat losses from the casing The heat transfer coefficient of the unit casing is given in W/(m2°C) when the temperature differential between the inside and...
Open the catalog to page 9TECHNICAL DATA - 2008 page 8 Casing – design and properties CEN-standard prEN 1886 classifies leakage rates for air handling units as follows. CEN-standard prEN 1886 classifies casing strength as follows: Casing tightness Leakage class Suction -400 Pa Leakage flow max l/s, m2 Pressure +700 Pa Leakage flow max l/s, m2 Highest rec. filter class Casing strength Casing class The leakage flow rate for a unit only subjected to suction must not exceed the above tabulated figures at -400 Pa. The leakage flow rate for a unit only subjected to pressure must not exceed the above tabulated figures at...
Open the catalog to page 10TECHNICAL DATA - 2008 page 9 Casing – design and properties The outdoor version of the unit is basically the same as the indoor version, and the technical specifications are the same. The outside of the casing is sealed between panels and frame with permanently elastic sealing compound to prevent moisture from entering the unit. Intake sections with grilles designed for an effective barrier against rain and snow are available. The unit is equipped with a curved EUBZ-01 roof to ensure good water run-off. The roof projects beyond the edge of the unit casing and has a turned-down edge. Even in...
Open the catalog to page 11All Fläkt Woods Group catalogs and technical brochures
-
HyPower-Geko
16 Pages
-
vQ STREAM
16 Pages
-
ATpicco
12 Pages
-
ReCOOLER HP
16 Pages
-
Ecodesign
8 Pages
-
diffuser range
8 Pages
-
ECONET ® PREMIUM
7 Pages
-
SEMCO
8 Pages
-
eQ ™ Air
202 Pages
-
EUMM Air conditioning unit Catalogue
245 Pages
-
Cooler and ReCooler
5 Pages
-
LVD Unit Heater, TEMPER
44 Pages
-
ATD Unit Heater
56 Pages
-
ControlMaster
4 Pages
-
Chilled beam Flexicool® IQID
5 Pages
-
Chilled beam Flexicool® IQIC
2 Pages
-
IPSUM Optimization System
16 Pages
-
Chilled beam iQ Star WEGA
13 Pages
-
Chilled Beam IQ Star STELLA
9 Pages
-
RoomMaster ABR unit
16 Pages
-
Supply air unit VEKA
4 Pages
-
TapMaster Air Handling Unit
16 Pages
-
eQ Energy Solutions
4 Pages