Catalog excerpts
Econet Compact Where renewable and recoverable energy combine
Open the catalog to page 1Our innovative Econet system is saving energy in several ways he components in Fläkt Woods’ innovative Econet system are connected together to provide a more reliable and more efficient AHU system. Heat recovery, heating and cooling are integrated into a common circuit as heating/cooling coils, pumps, valves, pipe systems, insulation, etc. The result is a shorter and more com- pact ventilation unit. This is highly beneficial from an environmental point of view because much less energy is used to transport the air through unnecessary components. Further development of the principle of energy...
Open the catalog to page 2Problem: Energy consumtions in buildings We spend approximately 90% of our time indoors. A lot of energy resources are consumed to maintain the right temperature and air quality, which is becoming more and more important. On average, 68% of a buildings energy needs are spent on heating, cooling and ventilation. Since we can affect both heating and cooling through the ventilation system we have a lot to work with. Together it means that you can make an impact on somewhere about half of the total energy consumption of a building when focusing on ventilation. That is something worth...
Open the catalog to page 3The design temperature in a heating system is traditionally 80/60°C. Econet is a low-temperature system, which means that it is possible to use heating water at a temperature of 25-35ºC. This means that there is a possibility of utilizing hot water that was previously considered to be unusable. The heat source for Econet can be the return water from district heating, waste/condenser heat or return water from radiator systems, for example. Econet can cool a building with other water temperatures than traditional systems. About 10ºC cooling water is in most cases sufficient as a feed...
Open the catalog to page 4Econet makes everybody a winner To lower the costs and care for the environment, Econet makes it possible to use alternate energy sources instead of traditional. Thanks to this, Econet makes everybody a winner. Heat energy from a chiller Refrigerators give off heat (condenser heat) when they produce cold. Liquid-borne condenser heat from chillers is very often at a low temperature (30-36ºC), which in the past has meant that it cannot be used and thus goes to waste. Econet can utilize the waste heat in order to heat the supply air. This way of saving energy is efficient in food shops and...
Open the catalog to page 5Over 2000 Econet systems installed Econet in supermarkets The regrigerated counters emit waste heat that Econet can reuse. This energy is often wasted, but Econet uses it to heat the supply air. References: ICA Maxi, Jönköping, Haninge, Sweden/Prisma, Turku, Finland Econet in industries Within industry there is usually waste heat available. This heat is frequently sufficient for Econet to heat the air, i.e. no primary heating is required to heat the air. Due to the recovery principle employed by Econet it is possible to position the units separately from each other, in addition there is no...
Open the catalog to page 6When using ECONET instead of the Rotary heat exchanger: From the recovery efficiency point of view the Rotary heat exchanger is outstanding compared to other recovery systems. However, there are circumstances where the RHE is not suitable. The following features are unique for Run around Coil systems, like ECONET and should therefore be the first choice when: - Hygienic applications, the recovery system has to be cleanable, the air streams has to be 100% separated from each other. No cross contamination allowed, no smell transfer. - Separated Air Handling, due to small equipment rooms, duct...
Open the catalog to page 7FläktWoods is a global leader in air management. We specialise in the design and manufacture of a wide range of air climate and air movement solutions. And our collective experience is unrivalled. FWG-Econet Compact-GB-2010.12-9011 © Copyright 2010 Fläkt Woods Group Our constant aim is to provide systems that precisely deliver required function and performance, as well as maximise energy efficiency. Solutions for all your air climate and air movement needs FläktWoods is providing solutions for ventilation and air climate for buildings as well as fan solutions for Industry and...
Open the catalog to page 8All Fläkt Woods Group catalogs and technical brochures
-
HyPower-Geko
16 Pages
-
vQ STREAM
16 Pages
-
ATpicco
12 Pages
-
ReCOOLER HP
16 Pages
-
Ecodesign
8 Pages
-
diffuser range
8 Pages
-
ECONET ® PREMIUM
7 Pages
-
SEMCO
8 Pages
-
eQ ™ Air
202 Pages
-
EUMM Air conditioning unit Catalogue
245 Pages
-
Cooler and ReCooler
5 Pages
-
LVD Unit Heater, TEMPER
44 Pages
-
ATD Unit Heater
56 Pages
-
ControlMaster
4 Pages
-
Chilled beam Flexicool® IQID
5 Pages
-
Chilled beam Flexicool® IQIC
2 Pages
-
IPSUM Optimization System
16 Pages
-
Chilled beam iQ Star WEGA
13 Pages
-
Chilled Beam IQ Star STELLA
9 Pages
-
RoomMaster ABR unit
16 Pages
-
Air Handling Unit EU
203 Pages
-
Supply air unit VEKA
4 Pages
-
TapMaster Air Handling Unit
16 Pages
-
eQ Energy Solutions
4 Pages