OT controller presentation When hygiene is crucial The operating room is the most critical zone in the hospital and as such the operating theatre must be a clean room in order to protect the patient. The ventilation and the filtration system must ensure an ultra clean air environment so as to not endanger the health of the patient. Infections are caused by various contaminants with the main sources of risk arising from the staff and the equipment either by means of direct contamination or from the indoor air (indirect contamination). The air is the greatest source of contamination and as...

Open the catalog to page 2
Operating Theatre Controller The key for an efficient and safe environment - 3

Advantages Simplicity The OT controller has been developed to be easy to plan, install and use and therefore an eQ air handling unit with a factory installed control system is a practical solution for consultants, installation engineers and end users. The integrated control equipment is supplied programmed, configured and tested, together with all the necessary field components. The control system conforms to EU directives (MD, EMD and LVD) and is CE marked. The OT controller is the perfect solution for both small installations with straightforward control functions and also for large...

Open the catalog to page 3
Operating Theatre Controller The key for an efficient and safe environment - 4

The following functions are available: Temperature control Humidity control Control of energy recovery (Econet or Ecoterm) Constant air flow Selection of 3 different air flows Constant over pressure of the room Night cooling option Night heating option Communication via TCP/IP Modbus, LONworks, , and BACnet as option The OT panel installed in the Operating theatre displayes the relevant information for the surgery team. • • • • • • The Time Temperature Hygrometry Selected mode Alarms in progress (for instance: overpressure not sufficient) Time left before next operation When an operating...

Open the catalog to page 4
Operating Theatre Controller The key for an efficient and safe environment - 5

Temperature control Room temperature is controlled by means of GT2 with a dead zone between the heating and cooling steps. In surgery mode (ISO 5-7) the supply air temperature is always maintained below the measured room temperature in order to maintain a laminar and controlled airflow. In stand-by mode the supply temperature is maintained between 16 and 25°C. When heating demand increases, control takes place using the following sequence: • Cooling valve SV2 closes to decrease cooling if the dehumidi­ fication is not active • Valve SV40 opens to increase heat recovery • Heating valve SV1...

Open the catalog to page 5
Operating Theatre Controller The key for an efficient and safe environment - 6

General information Component technical data As standard, the air handling unit’s electrical cabinet is located in a fixed panel next to one fan, except for the 005-011 unit where it is located on the roof for reasons of space. As an alternative the electrical cabinet can be located on an empty section anywhere on the unit (option). Using touch panels offer big advantages to hospital users. All incoming cables are connected to the electrical cabinet either from above or below. For outdoor units connection from below is recommended. Cable routing in double deck casings is internal, while for...

Open the catalog to page 6
Operating Theatre Controller The key for an efficient and safe environment - 7

Product Code 002 = ECONET, external heat 3 = Indoor with cabinet heater Pressure/Flow indication 5 = Supplied with STEQ 1 = HEPA filter ceiling 5 = Supplied with STEQ 2 = With controls, wall mounted cabinet Wiring diagram / Signs (h) •-' Temperature sensor 70 = Room temperature sensor 3 = Wall mounted sensor 5 = Supplied with STEQ 2 = With flow charts

Open the catalog to page 7
Operating Theatre Controller The key for an efficient and safe environment - 8

Fläkt Woods is providing solutions for ventilation and air climate for buildings as well as fan solutions for Industry and Infrastructure. Air Handling Units (AHUs) Modular, compact and small AHU units. Designed to ensure optimisation of indoor air quality, operational performance and service life. Advanced axial, centrifugal and boxed fans for general and specialist applications. Comprehensive range including high temperature and ATEX compliant options. Engineered for energy efficiency and minimised life cycle cost. Air Terminal Devices and Ducts Supply and exhaust diffusers and valves for...

Open the catalog to page 8

All Fläkt Woods Group catalogs and technical brochures

  1. HyPower-Geko

    16 Pages

  2. vQ STREAM

    16 Pages

  3. ATpicco

    12 Pages

  4. ReCOOLER HP

    16 Pages

  5. Ecodesign

    8 Pages

  6. SEMCO

    8 Pages

  7. eQ ™ Air

    202 Pages