vQ STREAM
16Pages

{{requestButtons}}

Catalog excerpts

vQ STREAM - 2

OPTIMAL CLIMATE: HYGIENIC. EFFICIENT. SUSTAINABLE. The HyPower-Geko fan coil units generate a whisperquiet and comfortable feel-good climate at maximum energy efficiency and optimal air treatment.

Open the catalog to page 2
vQ STREAM - 3

» Economy and ecology in harmony The signs of the times are clear Investors, plant engineers, planners, and architects no longer ask “whether” but “how” they can enhance the degree of sustainability of their plants and building management systems. Buildings are unique objects. Location, size, construction quality, and – increasingly, building engineering technology – determine values and returns. Energy matters substantially gain in significance since buildings absorb about 40 % of the world energy consumption and produce 21 % of world-wide greenhouse gas emissions. Energy costs will...

Open the catalog to page 3
vQ STREAM - 4

» Not just hot air, only full power The new dimensions of innovative air handling HyPower-Geko – The innovative fan coil unit in recirculating air mode convinces in three ways with an integral concept, that sets new standards: On maximum capacity with maximum energy efficiency and greatest possible demand on hygiene, HyPower-Geko performs individual air-conditioning at its best. HyPower-Geko means: • High Power • Hygienic Power • Hydronic Power Maximum power with precision • Maximum cooling capacity at highest speed (25 kW) • Powerful thanks to external pressure up to 150 Pa • Modular...

Open the catalog to page 4
vQ STREAM - 5

Power is in the air Concentrated power, efficiency and comfort for a perfect room climate EC fans made by quality manufacturer ebm-pabst Maximum cooling and heating capacity with minimum electric power consumption excellently awarded: EUROVENT energy label FCEER/FCOOP (class A) Condensate pump MaxiBlue Harmony all along the line: powerful, energy-efficient, low-noise and reliable owing to a new rotation-membrane principle. ISYteq controls Diverse control options in different stages of expansion - including: “Plug and Play” function, power-optimized operation and competent service with...

Open the catalog to page 5
vQ STREAM - 6

SIMPLY INTELLIGENTLY REGULATED ISYTEQ CONTROLS INNOVATIVE TECHNOLOGY WITH INTUITIVE USER INTERFACE Upon request, the proven ISYteq intelligent control system will be integrated into HyPower-Geko at the factory. Thus only completely tested equipment will be supplied to your construction site. Comprehensive control possibilities: • ontrol system for EC & AC fans C • nergy-optimized equipment E operation • quipment ready to operate E and highly competent service • lug-and-play functionality P • odbus RTU and TCP/IP M always on board • ACnet MSTP and TCP/IP B always on board • n Board Webserver...

Open the catalog to page 6
vQ STREAM - 7

Controls panels ISYteq system controls • .3’’ Touch Panel as a high-end solution 4 • Graphical and multilingual interface • imer is included T • different designs possible: 2 Hotel and Business layout • vailable with white or black frame A • ED bar for additional user experience L • orizontal or vertical installation H • emperature and humidity sensor T • n-wall and in-wall installation O • on-Browser panel N (Modbus communication) • odern cost-efficient design M • ontrol panel with LCD in protection C class IP20 • soft touch buttons for the user navigation 7 • or wall mounting with a black...

Open the catalog to page 7
vQ STREAM - 8

Basic unit – version A Basic unit – version B Basic unit – version C Without chamber for fans Free intake On-site filter must be provided With chamber for fans Without insulation of the fan chamber With integrated flat filter Duct and accessory connection possible With chamber for fans Like version B, but with interior acoustic insulation of the fan chamber Weight including water charge Weight including water charge Weight including water charge Basic unit in hygiene configuration Optional for cooling operation Additional equipment On request Only available for authorized sales regions...

Open the catalog to page 8
vQ STREAM - 9

Accessory items Optional selectable accessories • Spare filters (G2 or G4) • Flexible connection (intake or discharge) • ir-intake plenum with round connectors DN 250 A (insulated or non-insulated) Number of round connectors: Model size 1 = 3 pcs. Model size 2 = 4 pcs. Model size 3 = 5 pcs. Model size 4 = 6 pcs • Seal cap DN 250 for round connector • Transition piece for accessories • Sound attenuator (intake/discharge) • Suspension rail for ceiling

Open the catalog to page 9
vQ STREAM - 10

2-pipe system – chilled water Air volume flow V at external pressure of 50 Pa in speed 3 and capacity stage 1 Cooling capacity PCW 6 / 12 °C Air intake 27 °C / 46 % Capacity stage Motor data EC motor 1 ~ 230 Volt Sound power level at capacity stage 1

Open the catalog to page 10
vQ STREAM - 11

2-pipe system – warm water Air volume flow V at external pressure of 50 Pa in speed 3 and capacity stage 1 Thermal output PWW 70 / 50 °C Air intake 20 °C Capacity stage Motor data EC motor 1 ~ 230 Volt Sound power level at capacity stage 1

Open the catalog to page 11
vQ STREAM - 12

2-pipe system chilled or warm water Cooling or heating | Change-Over operation | Recirculating air Air volume flow V at external pressure of 50 Pa in speed 3 and capacity stage 1 Cooling capacity PCW 6 / 12 °C Air intake 27 °C / 46 % Capacity stage Motor data EC motor 1 ~ 230 Volt Sound power level at capacity stage 1

Open the catalog to page 12
vQ STREAM - 13

2-pipe system chilled or warm water Cooling or heating | Change-Over operation | Recirculating air Air volume flow V at external pressure of 50 Pa in speed 3 and capacity stage 1 Thermal output PWW 70 / 50 °C Air intake 20 °C Capacity stage Motor data EC motor 1 ~ 230 Volt Sound power level at capacity stage 1

Open the catalog to page 13
vQ STREAM - 14

4-pipe system – chilled and warm water Cooling and heating | Recirculating air Air volume flow V at external pressure of 50 Pa in speed 3 and capacity stage 1 Cooling capacity PCW 6 / 12 °C Air intake 27 °C / 46 % Capacity stage Motor data EC motor 1 ~ 230 Volt Sound power level at capacity stage 1

Open the catalog to page 14
vQ STREAM - 15

4-pipe system – chilled and warm water Cooling and heating | Recirculating air Air volume flow V at external pressure of 50 Pa in speed 3 and capacity stage 1 Cooling capacity PKW 70 / 50 °C Air intake 20 % Capacity stage Motor data EC motor 1 ~ 230 Volt Sound power level at capacity stage 1

Open the catalog to page 15

All Fläkt Woods Group catalogs and technical brochures

  1. HyPower-Geko

    16 Pages

  2. ATpicco

    12 Pages

  3. ReCOOLER HP

    16 Pages

  4. Ecodesign

    8 Pages

  5. SEMCO

    8 Pages

  6. eQ ™ Air

    202 Pages