190M
8Pages

{{requestButtons}}

Catalog excerpts

190M - 1

Medical ScopeMeter® Portable Oscilloscope Technical Data The 190M: a new generation of medical oscilloscope The 190M Medical ScopeMeter portable oscilloscope is a high-performance test tool built upon the legacy of Fluke and Fluke Biomedical oscilloscopes in partnership with real customers like you. The 190M is available with choice of two or four channels and offers an unprecedented level of performance, ruggedness, and portability. With the combined power of a high-performance oscilloscope, multimeter and paperless recorder in an easy-to-use test tool, the 190M is the one test tool you can rely on to tackle just about any troubleshooting task in the field. To minimize downtime and repair costs, you need to get to the root cause of problems as quickly as possible. The 190M offers a number of unique features to help you quickly set up the scope and diagnose difficult problems like intermittent events, signal fluctuations or drift. Extend your arsenal of troubleshooting capabilities with the new Fluke Biomedical 190M Medical ScopeMeter portable oscilloscope, designed to meet the demands of field service professionals. • Two or four electrically-isolated inputs • Fast sampling rate, up to 2.5 GS/s on two channels simultaneously with up to 400 ps resolution • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details (scope mode) • Dedicated 5000 count digital multimeter in two-channel model • Quad meter measurements via scope BNC inputs in four channel model • Connect-and-View ™ triggering for intelligent, automatic triggering on fast, slow and even complex signals • Frequency spectrum using FFT-analysis • High-resolution, non-interlaced video • Smart averaging • ScopeRecord roll mode gives 30,000 points per input channel and capture waveform sample data for up to 48 hours • TrendPlot, trend measurement readings for up to 22 days • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s) • Two USB ports make it easy to transfer data to a PC and store unlimited waveforms, screen captures and instrument setups on USB memory devices • New high-perfomance Li-ion battery technology delivers the longest battery life on the market • Charge spare battery using optional external battery charger • Easy-access battery door for quick swaps in the field • Security slot locks down oscilloscope with Kensington lock while unattended • Environmentally tested to meet IP-51 and withstand 3 g vibration or 30 g shock

Open the catalog to page 1
190M - 2

Oscilloscope modes Vertical deflection Number of channels Bandwidth Rise time Number of scope inputs Channel architecture Input coupling Input sensitivity Bandwidth limiter Normal/invert/variable Extended offset Input voltage Vertical resolution Accuracy Input impedance 2 4 200 MHz 1.7 ns 2 input channels plus external trigger 4 input channels All inputs fully insulated from each other and from ground Inputs may be activated in any combination AC or DC, with ground level indicator 2 mV/div to 100 V/div, plus variable attenuation User selectable: 20 kHz, 20 MHz or full bandwidth On each...

Open the catalog to page 2
190M - 3

190M-2 190M-4 NTSC, PAL, PAL+, SECAM; includes field 1, field 2 and line select Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz Pulse width triggering (on channel A) Pulse width qualified by time allows for triggering < t, > t, = t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns Time delay 1 Full screen of pre-trigger view or up to 100 screens (= 1,200 divisions) of posttrigger delay Dual slope triggering Triggers on both rising and falling edges alike N-cycle triggering Triggers on Nth occurrence of a trigger event; N to be set...

Open the catalog to page 3
190M - 4

Single vertical line ZOOM 190M-2 190M-4 Min/max and average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT resultant Ranges from full record overview to zoom-in up to sample level at any record length Meter Modes Meter inputs Number of readings Maximum resolution Input impedance Advanced meter functions Via 4 mm banana inputs, fully isolated Via BNC scope inputs from scope inputs and scope ground One at a time Up to 4 simultaneously 5,000 counts 99 counts 1 MΩ ± 1 %/14 pF ± 2 pF Auto/manual ranging, relative measurements (Zero reference),...

Open the catalog to page 4
190M - 5

Memory depth Min/max values Recording modes Stop-on-trigger Horizontal scale Zoom Memory 190M-2 190M-4 30,000 data points, each holding min/max pair of information Min/max values are created at samples that are measured at high sample rate, ensuring capture and display of glitches Single sweep, continuous roll, Single sweep, continuous roll, Start-on-trigger (through external), Start-on-trigger (through any channel), Stop-on-trigger (through external) Stop-on-trigger (through any channel) ScopeRecord mode can be stopped by an individual trigger event or by an interruption of a repetitive...

Open the catalog to page 5
190M - 6

General specifications Input voltage range Rated maximum floating voltage Maximum probe voltage Maximum BNC input voltage Maximum voltage on meter input CAT III 1000 V/CAT IV 600 V (Maximum voltage between any contact and earth-ground voltage level) CAT III 1000 V/CAT IV 600 V (Maximum voltage between any contact and earth-ground voltage level) CAT IV 300 V (Maximum voltage on BNC input directly) CAT III 1000 V/CAT IV 600 V (Safety designed banana input connectors) Memory save and recall Memory locations (internal) 15 waveform memory locations Two recording memories External data storage...

Open the catalog to page 6
190M - 7

Battery type (included) and capacity [+opt. battery] Battery charge indicator Battery operating time (with backlight low) Battery charging time Battery power saving functions 190M-2 190M-4 BP290; 2400 mAh [BP291 (4800 mAh) BP291; 4800 mAh optional] Battery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen Up to four hours using BP290 Up to seven hours using BP291 (included); up to eight hours using (included) BP291 (optional) 2.5 hours using BP290; 5 hours using 5 hours BP291 BP291 Auto power-down with adjustable power-down...

Open the catalog to page 7

All Fluke Biomedical catalogs and technical brochures

  1. IDA-6

    6 Pages

  2. RAYSAFE 452

    9 Pages

  3. RaySafe DXR+

    2 Pages

  4. BP Pump 2

    82 Pages

  5. ESA612

    4 Pages

  6. RaySafe Solo

    5 Pages

  7. PS320

    4 Pages

  8. DPM1B

    2 Pages

  9. 451B

    3 Pages

  10. 451P

    3 Pages

  11. INCU ?

    4 Pages

  12. 76-606DX

    2 Pages

  13. RaySafe Xi

    8 Pages

  14. RaySafe X2

    12 Pages

  15. ProSim 4

    6 Pages

  16. ESA615

    5 Pages

  17. VT305

    4 Pages

  18. ProSim

    8 Pages

Archived catalogs