451P Ion Chamber Survey Meter
30Pages

{{requestButtons}}

Catalog excerpts

451P Ion Chamber Survey Meter - 1

451P Ion Chamber Survey Meter Operators Manual PN FBC-0059 September 2013, Rev. 1 © 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

Open the catalog to page 1
451P Ion Chamber Survey Meter - 2

Warranty and Product Support Fluke Biomedical warrants this instrument against defects in materials and workmanship for one full year from the date of original purchase. During the warranty period, we will repair or, at our option, replace at no charge a product that proves to be defective, provided you return the product, shipping prepaid, to Fluke Biomedical. This warranty does not apply if the product has been damaged by accident or misuse or as the result of service or modification by other than Fluke Biomedical. IN NO EVENT SHALL FLUKE BIOMEDICAL BE LIABLE FOR CONSEQUENTIAL DAMAGES....

Open the catalog to page 2
451P Ion Chamber Survey Meter - 3

Contents (continued) Notices All Rights Reserved  Copyright 2013, Fluke Biomedical. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without the written permission of Fluke Biomedical. Copyright Release Fluke Biomedical agrees to a limited copyright release that allows you to reproduce manuals and other printed materials for use in service training programs and other technical publications. If you would like other reproductions or distributions, submit a written request to Fluke Biomedical. Unpacking and...

Open the catalog to page 3
451P Ion Chamber Survey Meter - 4

To ensure the accuracy of the Product is maintained at a high level, Fluke Biomedical recommends the product be calibrated at least once every 12 months. Calibration must be done by qualified personnel. Contact your local Fluke Biomedical representative for calibration. Certification This instrument was thoroughly tested and inspected. It was found to meet Fluke Biomedical’s manufacturing specifications when it was shipped from the factory. Calibration measurements are traceable to the National Institute of Standards and Technology (NIST). Devices for which there are no NIST calibration...

Open the catalog to page 4
451P Ion Chamber Survey Meter - 11

Introduction The Model 451P Ion Chamber Survey Meter (the Survey Meter) is a hand-held, pressurized, battery operated meter designed to measure gamma and x-ray radiation above 25 keV, and beta radiation above 1 MeV, using the latest CMOS and LCD technology. The Survey Meter case is constructed of high strength ABS plastic. A gasket seals moisture out of the Survey Meter and provides a cushion for the internal components. The readout consists of a 2½ digit liquid crystal display and a 100 segment analog bar graph. The bar graph contains a zero segment and twenty groups of five segments each....

Open the catalog to page 11
451P Ion Chamber Survey Meter - 12

Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. Table 1 is a list of symbols used on the product and in this manual. Table 1. Symbols Symbol Hazardous voltage. Risk of electric shock. Risk of Danger. Important information. See Manual. On/Off button This product complies with the WEEE Directive (2002/96/EC) marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic...

Open the catalog to page 12
451P Ion Chamber Survey Meter - 13

Ion Chamber Survey Meter Safety Information The battery door must be closed and locked before you operate the Product. Replace the batteries when the low battery indicator shows to prevent incorrect measurements. Comply with local and national safety codes. Use personal protective equipment. Carefully read all instructions. Do not touch voltages > 30 V ac rms, 42 V ac peak, or 60 V dc. Do not use the Product around explosive gas, vapor, or in damp or wet environments. Do not use and disable the Product if it is damaged. Do not use the Product if it operates incorrectly. Examine the case...

Open the catalog to page 13
451P Ion Chamber Survey Meter - 14

Each person who uses a product that senses and measures ionizing radiation must: o Be approved to do work where there is radiation Obey all applicable safety procedures and regulations Be approved to correctly interpret the indications on the product The user of this Product must read and strictly obey the instructions and precautions contained in the manuals. If you do not obey the instructions and precautions, there is a risk of injury. If you do not obey the instructions and precautions there is a risk that the Product will show incorrect indications. Before each use, do a battery check...

Open the catalog to page 14
451P Ion Chamber Survey Meter - 15

Ion Chamber Survey Meter Features Features The following sections describe the features of the Survey Meter. Overrange Rate If the instantaneous radiation rate measured by the Survey Meter exceeds 5 R/h, the 'R' in 'mR/h' or the 'Sv' in 'Sv/h' displayed will blink to notify the user that a potential error in the integrated radiation value exists. The blinking will stop when the integrated value is cleared. This, however, may also clear the log data RAM. Low Battery Indicator There are about 6 hours of operation remaining when the LOW BATTERY indicator first becomes visible. When the LOW...

Open the catalog to page 15
451P Ion Chamber Survey Meter - 17

Ion Chamber Survey Meter Specifications * Specifications are subject to change without notice. 1.4 Relative Response Side Face Front Figure 2. Model 451P Typical Energy Response

Open the catalog to page 17
451P Ion Chamber Survey Meter - 18

Dose equivalent units were determined using conversion coefficients at H*(10), found in I CRU 47, April, 1992. 1.4 Relative Response Side Front Figure 3. Model 451P DE SI Typical Energy Dependence

Open the catalog to page 18
451P Ion Chamber Survey Meter - 19

Ion Chamber Survey Meter Specifications Figure 4. Survey Meter Angular Res

Open the catalog to page 19
451P Ion Chamber Survey Meter - 20

Receiving Inspection Upon receipt of the Survey Meter: 1. Check the shipping cartons(s) and their contents for in-shipment damage. 2. Check that all items listed on the packing slip are present and in good condition. If damage is evident, make a claim with the carrier and contact Fluke immediately. If items are missing, contact Fluke. See How to Contact Fluke. Operation The following sections describe the operation of the Survey Meter.  Warning To prevent possible electrical shock, fire, or personal injury: • Do not put metal objects into connectors. Fluke recommends that you wait for a...

Open the catalog to page 20

All Fluke Biomedical catalogs and technical brochures

  1. RAYSAFE 452

    9 Pages

  2. RaySafe DXR+

    2 Pages

  3. BP Pump 2

    82 Pages

  4. ESA612

    4 Pages

  5. RaySafe Solo

    5 Pages

  6. PS320

    4 Pages

  7. DPM1B

    2 Pages

  8. 451B

    3 Pages

  9. 451P

    3 Pages

  10. INCU ?

    4 Pages

  11. 76-606DX

    2 Pages

  12. 190M

    8 Pages

  13. RaySafe Xi

    8 Pages

  14. RaySafe X2

    12 Pages

  15. ProSim 4

    6 Pages

  16. ESA615

    5 Pages

  17. VT305

    4 Pages

  18. ProSim

    8 Pages

Archived catalogs