ProSim 3 and 2
6Pages

{{requestButtons}}

Catalog excerpts

ProSim 3 and 2 - 1

Vital Signs Simulators Technical Data Don’t need a comprehensive patient monitor tester? The 6-in-1 ProSim 3 and 4-in-1 ProSim 2 Vital Signs Simulators are clear choices for biomedical engineers and field service technicians that need a quality, feature-rich device with high portability. Choose one of these modern vital signs simulators for preventive maintenance, troubleshooting and repair. The ProSim 3 and 2 feature the perfect amount of features for testing in the field. We like to call it the Just Right feature set, and it includes: • ECG • pacemaker • arrhythmia and performance testing • respiration • invasive blood pressure • temperature • cardiac output (ProSim 3 only) • fetal/maternal (ProSim 3 only) Key features • Portable, for evaluating the performance of patient monitors in the field • 20 % lighter and 25 % smaller than preceding technology • Just Right feature set includes: ECG, pacemaker, arrhythmia and performance testing, respiration, invasive blood pressure, temperature, cardiac output (ProSim 3 only), fetal/ maternal (ProSim 3 only) • 43 high-quality waveforms • With four IBP channels, ProSim 3 tests even the highest acuity scenarios • Stay-connected ECG posts for secure lead connections • Improved user interface and online Advantage Training demos • Upgraded DIN connectors ensure consistency with the ProSim family; minimize cable compatibility issues • Field upgradeable, and easily paired with other devices for comprehensive testing • ProSim 3 and 2 are 510(k) cleared products

Open the catalog to page 1
ProSim 3 and 2 - 2

Specifications General specifications Temperature Dimensions (LxWxH) USB device upstream port Battery life 8 hours continuous operation Safety standards Detailed specifications Normal-sinus-rhythm waveform ECG Reference The ECG amplitudes specified are for Lead II (calibration), from the baseline to the peak of the R wave. All other leads are proportional. Normal sinus rhythm 12-lead configuration with independent outputs referenced to right leg (RL). Output to 10 universal ECG Jacks, color-coded to AHA and IEC Standards Amplitude accuracy ± 2 % of setting Lead II. All other leads ± 5 %...

Open the catalog to page 2
ProSim 3 and 2 - 3

Paced arrhythmias Atrial 75 BPM Asynchronous 75 BPM Demand with frequent sinus beats Demand with occasional sinus beats Atrio-ventricular sequential Noncapture (one time) Nonfunction Power-on default Left focus, standard timing (except where specified) Supraventricular arrhythmia Atrial fibrillation (coarse or fine); atrial flutter sinus arrhythmia; missed beat (one time); atrial tachycardia; paroxysmal atrial tachycardia; nodal rhythm; and supraventricular tachycardia Premature arrhythmia (All one-time events) Premature atrial contraction (PAC); premature nodal contraction (PNC); PVC1 left...

Open the catalog to page 3
ProSim 3 and 2 - 4

Invasive blood pressure Channels 4, each independently settable with identical parameters and are individually electronically isolated from other signals Input/output impedance Exciter input range Exciter-input frequency range Transducer sensitivity Pressure accuracy ± 2 % of setting + 2 mmHg (valid for dc excitation only) Static Levels, Channel 1 Static Levels, Channel 2 Static Levels, Channel 3 (ProSim 3 only) Static Levels, Channel 4 (ProSim 3 only) Dynamic waveforms, Channel 1 Arterial: 120/80, Radial Artery: 120/80, Left ventricle: 120/00, Right ventricle: 25/00 Dynamic waveforms,...

Open the catalog to page 4
ProSim 3 and 2 - 5

Output connector Power-on default Cardiac output (ProSim 3 only) Catheter type Calibration coefficient Blood temperature Injectate volume Injectate temperature Cardiac output Faulty-injectate curve Waveform for simulation available Left-to-right shunt curve Waveform for simulation available Calibrated pulse Output connector Power-on default 2.5 liters perminute, 0 °C injectate ProSim 4 Vital Signs Simulator

Open the catalog to page 5
ProSim 3 and 2 - 6

Ordering information Models/descriptions ProSim 3 ProSim Vital Signs Simulator ProSim 2 ProSim Vital Signs Simulator Standard accessories ProSim 2/3 Instruction Sheet (multi-language) 4253822 ProSim 2/3 Users Manual CD 614487 Two 9-volt alkaline batteries (minimum 8 hours continuous use) 2392173 IBP Cable, unterminated 2392199 3010-0289FG, CI-3 Cable Assembly (Cardiac Output Box; ProSim 3 only) 1671807 USB cable 2248623 ProSim 2/3 Carrying Case AC power cords 4219453 AC/DC Power Supply 769422 AC Power Cord (Schuko) 284174 AC Power Cord (USA) 769455 AC Power Cord (UK) 658641 AC Power Cord...

Open the catalog to page 6

All Fluke Biomedical catalogs and technical brochures

  1. IDA-6

    6 Pages

  2. RAYSAFE 452

    9 Pages

  3. RaySafe DXR+

    2 Pages

  4. BP Pump 2

    82 Pages

  5. ESA612

    4 Pages

  6. RaySafe Solo

    5 Pages

  7. PS320

    4 Pages

  8. DPM1B

    2 Pages

  9. 451B

    3 Pages

  10. 451P

    3 Pages

  11. INCU ?

    4 Pages

  12. 76-606DX

    2 Pages

  13. 190M

    8 Pages

  14. RaySafe Xi

    8 Pages

  15. RaySafe X2

    12 Pages

  16. ProSim 4

    6 Pages

  17. ESA615

    5 Pages

  18. VT305

    4 Pages

  19. ProSim

    8 Pages

Archived catalogs