Vital Signs Simulators Technical Data Don’t need a comprehensive patient monitor tester? The 6-in-1 ProSim 3 and 4-in-1 ProSim 2 Vital Signs Simulators are clear choices for biomedical engineers and field service technicians that need a quality, feature-rich device with high portability. Choose one of these modern vital signs simulators for preventive maintenance, troubleshooting and repair. The ProSim 3 and 2 feature the perfect amount of features for testing in the field. We like to call it the Just Right feature set, and it includes: • ECG • pacemaker • arrhythmia and performance testing • respiration • invasive blood pressure • temperature • cardiac output (ProSim 3 only) • fetal/maternal (ProSim 3 only) Key features • Portable, for evaluating the performance of patient monitors in the field • 20 % lighter and 25 % smaller than preceding technology • Just Right feature set includes: ECG, pacemaker, arrhythmia and performance testing, respiration, invasive blood pressure, temperature, cardiac output (ProSim 3 only), fetal/ maternal (ProSim 3 only) • 43 high-quality waveforms • With four IBP channels, ProSim 3 tests even the highest acuity scenarios • Stay-connected ECG posts for secure lead connections • Improved user interface and online Advantage Training demos • Upgraded DIN connectors ensure consistency with the ProSim family; minimize cable compatibility issues • Field upgradeable, and easily paired with other devices for comprehensive testing • ProSim 3 and 2 are 510(k) cleared products
Open the catalog to page 1Specifications General specifications Temperature Dimensions (LxWxH) USB device upstream port Battery life 8 hours continuous operation Safety standards Detailed specifications Normal-sinus-rhythm waveform ECG Reference The ECG amplitudes specified are for Lead II (calibration), from the baseline to the peak of the R wave. All other leads are proportional. Normal sinus rhythm 12-lead configuration with independent outputs referenced to right leg (RL). Output to 10 universal ECG Jacks, color-coded to AHA and IEC Standards Amplitude accuracy ± 2 % of setting Lead II. All other leads ± 5 %...
Open the catalog to page 2Paced arrhythmias Atrial 75 BPM Asynchronous 75 BPM Demand with frequent sinus beats Demand with occasional sinus beats Atrio-ventricular sequential Noncapture (one time) Nonfunction Power-on default Left focus, standard timing (except where specified) Supraventricular arrhythmia Atrial fibrillation (coarse or fine); atrial flutter sinus arrhythmia; missed beat (one time); atrial tachycardia; paroxysmal atrial tachycardia; nodal rhythm; and supraventricular tachycardia Premature arrhythmia (All one-time events) Premature atrial contraction (PAC); premature nodal contraction (PNC); PVC1 left...
Open the catalog to page 3Invasive blood pressure Channels 4, each independently settable with identical parameters and are individually electronically isolated from other signals Input/output impedance Exciter input range Exciter-input frequency range Transducer sensitivity Pressure accuracy ± 2 % of setting + 2 mmHg (valid for dc excitation only) Static Levels, Channel 1 Static Levels, Channel 2 Static Levels, Channel 3 (ProSim 3 only) Static Levels, Channel 4 (ProSim 3 only) Dynamic waveforms, Channel 1 Arterial: 120/80, Radial Artery: 120/80, Left ventricle: 120/00, Right ventricle: 25/00 Dynamic waveforms,...
Open the catalog to page 4Output connector Power-on default Cardiac output (ProSim 3 only) Catheter type Calibration coefficient Blood temperature Injectate volume Injectate temperature Cardiac output Faulty-injectate curve Waveform for simulation available Left-to-right shunt curve Waveform for simulation available Calibrated pulse Output connector Power-on default 2.5 liters perminute, 0 °C injectate ProSim 4 Vital Signs Simulator
Open the catalog to page 5Ordering information Models/descriptions ProSim 3 ProSim Vital Signs Simulator ProSim 2 ProSim Vital Signs Simulator Standard accessories ProSim 2/3 Instruction Sheet (multi-language) 4253822 ProSim 2/3 Users Manual CD 614487 Two 9-volt alkaline batteries (minimum 8 hours continuous use) 2392173 IBP Cable, unterminated 2392199 3010-0289FG, CI-3 Cable Assembly (Cardiac Output Box; ProSim 3 only) 1671807 USB cable 2248623 ProSim 2/3 Carrying Case AC power cords 4219453 AC/DC Power Supply 769422 AC Power Cord (Schuko) 284174 AC Power Cord (USA) 769455 AC Power Cord (UK) 658641 AC Power Cord...
Open the catalog to page 6All Fluke Biomedical catalogs and technical brochures
-
IDA-6
6 Pages
-
RAYSAFE 452
9 Pages
-
451P Ion Chamber Survey Meter
30 Pages
-
RaySafe Dose Viewer
10 Pages
-
RaySafe DXR+
2 Pages
-
BP Pump 2
82 Pages
-
ProSim SPOT Light
4 Pages
-
ESA612
4 Pages
-
Electrical Safety Analyzers
8 Pages
-
VT900A Datasheet
6 Pages
-
VT900A + VAPOR
7 Pages
-
ESA614 Datasheet
6 Pages
-
Gas Flow Family Brochure
2 Pages
-
RaySafe Solo Specifications
5 Pages
-
RaySafe Solo
5 Pages
-
PS320
4 Pages
-
DPM1B
2 Pages
-
SigmaPace™ 1000
8 Pages
-
Impulse 6000D/7000DP
8 Pages
-
451B
3 Pages
-
451P
3 Pages
-
965 Stack Monitor
3 Pages
-
INCU ?
4 Pages
-
QA-ES Series II
4 Pages
-
76-606DX
2 Pages
-
07-CRXW and 07-QRX
4 Pages
-
190M
8 Pages
-
RaySafe Xi
8 Pages
-
RaySafe X2
12 Pages
-
ProSim 4
6 Pages
-
ESA615
5 Pages
-
VT305
4 Pages
-
Gas flow analyzer
4 Pages
-
ProSim
8 Pages
Archived catalogs
-
Impulse 6000D/7000DP - 2013
8 Pages