Group: Fortive
Catalog excerpts

Wireless CR RADCHEX and QA RADCHEX Technical Data The wireless 07-CRXW CR RADCHEX and 07-QRX QA RADCHEX are factory radiation-calibrated, NISTtraceable light meters that can be used to calibrate (balance) CR plate readers (also radiation-calibrated light meters) in the field. The CR plate reader in the field will be calibrated and traceable to the Fluke Biomedical factory radiation-calibrated and traceable x-ray-produced light exposure. Both 07-CRXW and 07-QRX have the same x-ray energy response as a CR system (x-ray-to-light conversion efficiency is the same for various beam conditions). This enables them to be used as accurate and precise replacements for the plate reader’s light measurement value (exposure index value). Most importantly, the 07-CRXW and 07-QRX can save valuable time when calibrating or accessing CR readers and AEC used with multiple x-ray systems. These x-ray systems may have different filtration and beam characteristics even when located in the same department or imaging center. Balancing system performance and dose is an important QA requirement best satisfied with either the 07-CRXW or 07-QRX. • Calibrates computed radiography (CR) plate readers and automatic exposure control (AEC) • Assesses ongoing performance of CR plate reader, AEC, and automatic programmed radiography (APR) • Sets and maintains desired clinical system speed (dose) of the CR system • Calibrates CR plate readers in the field to be traceable to a factory radiation-produced light condition Links radiation exposure (mR) to the front of the plate accurately and • predictably to a CR light measurement value (CRLU) Provides a reliable and reproducible method of accurately maintaining • a CR manufacturers’ specific factory calibration Provides three different tube-head filtration choices for users who desire • a non-filtered beam condition for field plate reader calibration • Software selections of multiple beam conditions for different CR manufacturers • Ideal tools for service engineers, physicists, and quality assurance personnel
Open the catalog to page 1
Applications 07-CRXW CR RADCHEX The wireless 07-CRXW is ideal for use by service engineers to initially calibrate and troubleshoot the CR plate reader, AEC, and density selector settings. Physicists use 07-CRXW to assess the performance of CR-AEC for compliance to clinical system speed objectives and patient dose. Radiology managers can use 07-CRXW to assist in the establishment of technique charts and training to determine ALARA techniques for various exam types. QA personnel can use 07-CRXW to periodically document the performance of the CR system and to compare CR to film/screen systems...
Open the catalog to page 2
Technical specifications X-ray energy dependence Simulates relative light output of photostimulatable phosphor plate (PSP) within ± 3 % over kVp range of 60 kVp to 120 kVp and a patient equivalent thickness range of 5 cm to 35 cm (within specified operating rates) Digital range Computed radiography light units; CRLU (AEC#); 0 to 500, CRLU (AEC#); 0 to 5000 (07-QRX) Minimum CRLU rate 1.5/s (approx. 0.15 mR/s entrance exposure rate), 7/sec (approx. 0.7 mR/sec entrance exposure rate) (07-QRX) Maximum CRLU rate 2500/s (approx. 250 mR/s entrance exposure rate), 25000/sec (approx. 2500 mR/s...
Open the catalog to page 3
About Fluke Biomedical Fluke Biomedical is the world’s leading manufacturer of quality biomedical test and simulation products. In addition, Fluke Biomedical provides the latest medical imaging and oncology quality-assurance solutions for regulatory compliance. Today, biomedical personnel must meet the increasing regulatory pressures, higher quality standards, and rapid technological growth, while performing their work faster and more efficiently than ever. Fluke Biomedical provides a diverse range of software and hardware tools to meet today’s challenges. Fluke Biomedical Regulatory...
Open the catalog to page 4All Fluke Health Solutions catalogs and technical brochures
-
ESA612
6 Pages
-
PS320
5 Pages
-
Impulse 6000D/7000DP
15 Pages
-
190M
8 Pages
-
ESA615
7 Pages
-
Gas flow analyzer
2 Pages
-
ProSim 3 and 2
7 Pages
-
Product catalog
40 Pages
-
IDA-6 Flyer
1 Pages
-
ProSim SPOT Light
4 Pages
-
VT900A Datasheet
6 Pages
-
VT900A + VAPOR
7 Pages
-
ESA614 Datasheet
6 Pages
-
Gas Flow Family Brochure
2 Pages
-
RaySafe Solo Specifications
5 Pages
-
451B
3 Pages
-
451P
3 Pages
-
ProSim 4
6 Pages
Archived catalogs
-
QA-ES Series II
4 Pages
-
RAYSAFE 452
9 Pages
-
451P Ion Chamber Survey Meter
30 Pages
-
RaySafe Dose Viewer
10 Pages
-
RaySafe DXR+
2 Pages
-
BP Pump 2
82 Pages
-
Electrical Safety Analyzers
8 Pages
-
RaySafe Solo
5 Pages
-
DPM1B
2 Pages
-
SigmaPace™ 1000
8 Pages
-
965 Stack Monitor
3 Pages
-
INCU ?
4 Pages
-
76-606DX
2 Pages
-
RaySafe Xi
8 Pages
-
RaySafe X2
12 Pages
-
Impulse 6000D/7000DP - 2013
8 Pages
-
VT305
4 Pages
-
ProSim
8 Pages