BP Pump 2

BP Pump 2
1 / 82 PagesView full catalog

BP Pump 2

Product catalog summary
Introduction and Specifications
The BP Pump 2 by Fluke Biomedical is a Non-invasive Blood Pressure (NIBP) Simulator and Tester. It is designed for use with oscillometric Non-Invasive Blood Pressure Monitors (NIBPMs) and offers features such as user-defined simulations, printer output, and various pressure tests. It is available in two models: BP Pump 2L (Basic Model) and BP Pump 2M (High-Accuracy Model), capable of generating pressures up to 400 mmHg.
Warranty and Product Support
Fluke Biomedical provides a one-year warranty covering defects in materials and workmanship, excluding misuse or unauthorized modifications. Technical support is available via email or phone.
Unpacking and Inspection
Inspect the shipping carton for damage upon receipt and ensure the instrument is free from physical damage before use.
Setup, Maintenance, and Support
Setup involves configuring printer output, user-defined simulations, and units of measure. Regular maintenance includes cleaning and calibration, with specific packing instructions for returns.
Operation
The manual provides instructions for conducting pressure tests, including leak, relief, and source tests, and simulations for standard blood pressure, patient conditions, arrhythmias, and respiratory artifacts.
Returns and Refunds
Products must be returned within 90 days for a refund or credit, subject to restocking fees, and require a Return Material Authorization (RMA) number.
Certification and Safety
The instrument meets Fluke Biomedical’s manufacturing specifications and is traceable to NIST standards. Unauthorized modifications may result in hazards.
Appendices
Includes ECG interface, FAQs, abbreviations, and computer control commands.
Key Features
The Tester includes pressure leak testing, relief valve testing, pressure gauge measurements, and NIBP simulations for different patient conditions. It supports auto sequences with optional reports and can simulate both adult and neonatal cuffs.
General Safety Considerations
The Tester complies with safety standards such as UL 3101-1 and EN61010-1:2001. It should not be connected to a patient and must be used in dry, non-explosive environments.
Instrument Familiarity
The Tester features various components, including a home key, soft keys, number keys, and ports for ECG and printer connections.
Specifications
The Tester operates on a mains voltage range of 100 - 240 V AC and supports various pressure measurement units. It includes ECG signal capabilities and supports heart rate accuracy within specified conditions.
Accessories
Standard accessories include an operator's manual, warranty card, tubing, fittings, and a power cord. Optional accessories are available for purchase.
Setup Menu Navigation
The Setup menu includes options such as BP Pump 2 Setup, User-Defined Simulations, Language, Printer Output, and Units of Measure.
Printer Output Configuration
Printer output can be configured through the SETUP menu.
User-Defined Simulations
The Tester supports up to nine user-definable blood pressure simulations with parameters like Systolic, Diastolic, Pulse Volume, and Heart Rate.
Language Settings
The Tester supports multiple languages, including English and Spanish.
Units of Measure
Measurement units can be defined as mmHg, kPa, cmH2O, inH2O, and PSI.
Self Test
The Tester performs a self-test displaying software version, serial number, and model number.
Zero Pressure
This function allows re-zeroing of pressure.
Enable ECG Signal
ECG output can be enabled or disabled.
Maintenance and Support
The Tester requires minimal maintenance, with annual calibration recommended.
Operation Overview
The Tester uses a microprocessor to control components like a diaphragm pump and solenoid valves.
Configurations for Devices Under Test (DUT)
Connections involve the NIBPM unit, a cuff, and the Tester.
Pressure Tests
  • Pressure Leak Test: Measures pressure loss over time.
  • Pressure Relief Test: Increases pressure until the relief valve opens.
  • Pressure Source Test: Generates and measures pressure for static calibration.
  • Pressure Gauge Test: Measures static pressure generated by an external source.
Simulations
  • Standard BP Simulations: Variations of blood pressure scenarios.
  • Patient Condition Simulations: Mimic different patient conditions.
  • Arrhythmia Simulations: Simulate conditions like premature contractions.
  • Respiratory Artifact Simulations: Exhibit beat-to-beat variations in blood pressure.
Key Procedures
  • Use soft keys to navigate through tests and simulations.
  • Ensure the NIBP monitor is in the correct mode for testing.
  • Compare values on the NIBP unit with those on the Tester.
Conversion Factors
Provides conversion factors for pressure units.
Error Handling
Contact Fluke Biomedical Service Center for assistance with repeatable error messages.
Neonate Simulations
Test the ability of NIBP monitors to detect blood pressure in neonatal patients.
Wrist Simulations
Test wrist cuff NIBP monitors using an external cuff.
User-Defined Simulations
Allow customization based on previously defined settings.
Auto Sequences
Create up to nine customized sequences for pressure tests and simulations.
Remote Operation
Facilitated through an RS-232 connection with Ansur software support.
Internal Cuff and Compliance
Discusses the use of an internal cuff to ensure accurate simulations.
External Cuff Usage
Configured to work with an external cuff using connectors.
Abbreviations
Provides a list of abbreviations used in the document.
Computer Control Commands
Details computer control commands for the tester.
See more

Catalog excerpts

BP Pump 2-1

BP Pump 2 NIBP Simulator and Tester Operators Manual PN 2196592 June 2007 © 2007 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies.

 Open the catalog to page 1
BP Pump 2-2

Warranty and Product Support Fluke Biomedical warrants this instrument against defects in materials and workmanship for one year from the date of original purchase. During the warranty period, we will repair or at our option replace, at no charge, a product that proves to be defective, provided you return the product, shipping prepaid, to Fluke Biomedical. This warranty covers the original purchaser only and is not transferable. The warranty does not apply if the product has been damaged by accident or misuse or has been serviced or modified by anyone other than an authorized Fluke Biomedical...

 Open the catalog to page 2
BP Pump 2-3

Notices All Rights Reserved © Copyright 2007, Fluke Biomedical. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without the written permission of Fluke Biomedical. Copyright Release Fluke Biomedical agrees to a limited copyright release that allows you to reproduce manuals and other printed materials for use in service training programs and other technical publications. If you would like other reproductions or distributions, submit a written request to Fluke Biomedical. Unpacking and Inspection Follow standard...

 Open the catalog to page 3
BP Pump 2-4

Return Procedure All items being returned (including all warranty-claim shipments) must be sent freight-prepaid to our factory location. When you return an instrument to Fluke Biomedical, we recommend using United Parcel Service, Federal Express, or Air Parcel Post. We also recommend that you insure your shipment for its actual replacement cost. Fluke Biomedical will not be responsible for lost shipments or instruments that are received in damaged condition due to improper packaging or handling. Use the original carton and packaging material for shipment. If they are not available, we recommend...

 Open the catalog to page 4
BP Pump 2-5

Restrictions and Liabilities Information in this document is subject to change and does not represent a commitment by Fluke Biomedical. Changes made to the information in this document will be incorporated in new editions of the publication. No responsibility is assumed by Fluke Biomedical for the use or reliability of software or equipment that is not supplied by Fluke Biomedical, or by its affiliated dealers. Manufacturing Location The BP Pump 2 Non-invasive Blood Pressure Simulator and Tester is manufactured in Everett, Washington by Fluke Biomedical, 6920 Seaway Blvd., Everett, WA, U.S.A.

 Open the catalog to page 5
BP Pump 2-10

BP Pump 2 Operators Manual

 Open the catalog to page 10
BP Pump 2-12

BP Pump 2 Operators Manual

 Open the catalog to page 12
BP Pump 2-14

BP Pump 2 Operators Manual

 Open the catalog to page 14
BP Pump 2-15

Introduction and Specifications Introduction Introduction The Fluke Biomedical BP Pump 2 Non-Invasive Blood Pressure Simulator and Tester, hereafter known as the “Tester”, is a multi-purpose test instrument for use with oscillometric Non-Invasive Blood Pressure Monitors (NIBPMs). The Tester provides dynamic blood pressure simulations, static calibration, automated leak testing, and pressure relief valve testing. The following models are available: • BP Pump 2L (Basic Model) BP Pump 2M (High-Accuracy Model) The Tester allows you to verify the performance claims of different blood pressure monitors....

 Open the catalog to page 15
BP Pump 2-16

BP Pump 2 Operators Manual Tester pressure accuracy can be improved by upgrading to a high-accuracy pressure transducer. This is a factory service upgrade and is provided to customers wanting to meet the DIN EN 1060 requirements for pressure measurement accuracy. For more information, refer to “Setup, Maintenance, and Support: Maintenance and Support.” General Safety Considerations This Tester complies with safety and technical requirements described in the following directives: • UL 3101-1, Electrical Equipment for Laboratory Use; Part 1: General Requirements. • CAN/CSA C22.2 No. 1010.1 (1992),...

 Open the catalog to page 16
BP Pump 2-17

Introduction and Specifications General Safety Considerations Warnings and Cautions Users are advised to read the manual carefully, observing all warnings and cautions, before attempting to set up and operate the Tester. A Warning identifies hazardous conditions and actions that could cause bodily harm or death. A Caution identifies conditions and actions that could damage the Tester or the equipment under test, or cause permanent loss of data. W X Warning To avoid possible electric shock or personal injury, follow these guidelines: • Read the Users Manual before operating the Tester. Use this...

 Open the catalog to page 17
BP Pump 2-18

BP Pump 2 Operators Manual Always connect the system power cord directly to a three-prong receptacle with a functional ground. Never use a two-prong plug adapter to connect primary power to the Tester, thereby disconnecting the utility ground. Disconnect the Tester from the power source before changing the supply voltage. The Tester operates at a range of 100 to 240 volts. W Caution To avoid damage to the Tester or adverse affects on its performance, follow these guidelines: • • Do not expose the system to temperature extremes. Ambient temperatures should remain between 15° C and 40° C. System...

 Open the catalog to page 18
BP Pump 2-19

Introduction and Specifications Instrument Familiarity Instrument Familiarity Figure 1-1 shows the Tester. The top and side panel components are described in Table 1-2 and the number key functions are described in Table 1-3. Figure 1-1. Tester Top and Side Panel Components

 Open the catalog to page 19
BP Pump 2-20

BP Pump 2 Operators Manual Table 1-2. Top and Side Panel Components Label Returns the operator to the Main Menu. Makes dynamic assignments based on the current screen. Number (Test and Simulations) Keys Allows the operator to perform auto sequences and simulations using numeric keys. Advances to the next menu or saves/selects options. Pulse Indicator LED blinks in synchronization with beeper, indicating that the pump is generating a simulated blood pressure pulse. Allows connection of optional ECG accessory (refer to Appendix, ECG Option). Printer Port Provides D-25 female connector for external...

 Open the catalog to page 20

Archived catalogs

  1. RAYSAFE 452

    9  Pages

  2. RaySafe X2

    12  Pages

  3. RaySafe DXR+

    2  Pages

  4. RaySafe Solo

    5  Pages

  5. DPM1B

    2  Pages

  6. INCU ?

    4  Pages

  7. 76-606DX

    2  Pages

  8. RaySafe Xi

    8  Pages

  9. VT305

    4  Pages

  10. ProSim

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.