ESA615

ESA615

ESA615

Product catalog summary
Overview: The ESA615 Electrical Safety Analyzer is a portable device designed for healthcare technology management professionals to perform electrical safety testing on medical equipment. It supports both simple and comprehensive testing, including line voltage, ground wire resistance, insulation resistance, device current, and leakage tests. It also offers ECG simulation and point-to-point tests, adhering to global electrical safety standards such as ANSI/AAMI ES1, NFPA-99, IEC62353, IEC60601-1, and AS/NZS 3551.
Key Features:
  • Portable and ergonomic design with an integrated handle and tilt stand.
  • Automated test sequences for compliance with global standards.
  • User-friendly interface with ECG waveform tests and dual-lead measurements.
  • Five applied parts jacks and optional expander box for up to 12-lead ECG testing.
  • Data entry via barcode, external keyboard, or on-board keypad.
  • Replaceable mains fuses and custom language selections.
  • Rugged design tested for field applications with a two-year extended warranty.
Technical Specifications:
  • Voltage: Mains voltage range from 90.0 V to 264.0 V AC RMS, point-to-point voltage up to 300.0 V AC RMS.
  • Earth Resistance: Two-wire mode with test current over 200 mA AC.
  • Equipment Current: Range from 0.0 A to 20.0 A with specific duty cycles.
  • Leakage Current: Modes include AC + DC, AC only, and DC only with various ranges and accuracies.
  • Insulation Resistance: Ranges from 0.5 MΩ to 100.0 MΩ with specific accuracies.
  • ECG Performance: Various waveforms and rates with specific accuracy levels.
Test Standards and Sequences: Built-in test sequences for IEC60601-1, IEC62353, NFPA-99, and ANSI/AAMI ES1, covering devices like patient monitors, defibrillators, infusion pumps, and ultrasound devices.
Communications: USB and wireless connectivity for data transfer and control by a computer.
Power Ratings: Supports mains voltage outlets of 120 V AC and 230 V AC with a frequency range of 47 to 63 Hz.
Physical Specifications: Dimensions are 17.6 cm x 8.4 cm x 28.5 cm, weighing 1.6 kg.
Ordering Information: Various models available for different regions, with options for Ansur automation software.
Environmental Conditions: Operating temperature from 10 ºC to 40 ºC, storage temperature from -20 ºC to 60 ºC, and operating humidity from 10% to 90% non-condensing.
Warranty and Support: Two-year extended warranty available, with global support network.
About Fluke Biomedical: A leading manufacturer of biomedical test and simulation products, committed to quality standards and certifications such as ISO 9001 and ISO 13485.
See more

Catalog excerpts

ESA615-1

Technical data ESA615 Electrical Safety Analyzer The ESA615 Electrical Safety Analyzer brings fast and simple automated testing to a portable analyzer for healthcare technology management professionals that perform electrical safety testing on medical equipment both in the field and in facilities. Whether it is simple testing or comprehensive analysis, the ESA615 can do it all. This multifaceted device performs all primary electrical safety tests, including line (mains) voltage, ground wire (protective earth) resistance, insulation resistance, device current, and lead (patient) leakage tests. It also offers ECG simulation and point–to-point voltage, leakage, and resistance tests. Versatile to global electrical safety standards of choice, ESA615 tests to ANSI/AAMI ES1, NFPA-99, IEC62353 (VDE751) IEC60601-1 (2nd and 3rd editions) and AS/NZS 3551. The ESA615 is an all-in-one solution with a safety analyzer and ECG simulator in a single test instrument. Key features • Portable, ergonomic design with an integrated handle and tilt stand • On-board automation with automated test sequences for easy compliance to key global electrical safety standards (ANSI/AAMI ES-1 (NFPA-99), IEC62353 (VDE751), IEC60601-1 2nd and 3rd editions, and AS/NZS 3551) • User-friendly interface for streamlined testing • ECG waveform tests and dual-lead measurements combine the functionality of a simulator and safety analyzer in a single test tool • Five applied parts jacks and easy ECG snap connection; optional expander box for up to 12-lead ECG testing • Easy data entry through barcode external keyboard or on-board keypad • 20 A at 120 V current capability • Replaceable mains fuses keep your unit in the field and out of the repair shop • Custom language selections include: English, French, German, Spanish, Italian and Portuguese • Rigorously tested for rugged field applications with CE and CSA in addition to Fluke-qualityruggedness for long-term reliability • Two-year extended warranty (no-cost available after first-year calibration at any authorized Fluke Biomedical Service Center) • Global support network delivering prompt service and peace of mind to Fluke Biomedi

 Open the catalog to page 1
ESA615-2

Automated: Pre-set templates allow you to test to the global standard of your choices at the push of a button. Let the unit guide you through the test steps quickly and accurately in three simple steps: 1. Select the test sequence corresponding to your standard of choice 2. Initiate the automated test sequence. 3. Store the results on-board or wirelessly export to your PC in seconds. It is that easy. The automated test sequences are easily customized to suit individual testing requirements. Portable: The ESA615 is a small, lightweight analyzer with an integrated handle to carry from place to...

 Open the catalog to page 2
ESA615-3

Frequency response/accuracy ± (1 % of reading + (1 μA or 1 LSD, whichever is greater)) ± (2 % of reading + (1 μA or 1 LSD, whichever is greater)) ± (4 % of reading + (1 μA or 1 LSD, whichever is greater)) ± (5 % of reading + (1 μA or 1 LSD, whichever is greater)) Accuracy for Isolation, MAP, Direct AP, Alternative AP, and Alternative Equipment leakage tests all ranges are: • At 120 V ac + (2.5 μA or 1 LSD, whichever is greater) • At 230 V ac additional ± 3.0 % and + (2.5 μA or 1 LSD, whichever is greater) For Alternative equipment, Alternative AP, and Direct AP leakage tests, the leakage values...

 Open the catalog to page 3
ESA615-4

ECG performance waveforms Accuracy ±2% ± 5 % for amplitude of 2 Hz square wave only, fixed at 1 mV lead II configuration Ventricular fibrillation Square wave (50 % duty cycle) Sine wave Triangle wave Pulse (63 ms pulse width) Test standards Available selections Built-in test sequences IEC60601-1 3rd Edition Patient Monitor, Defibrillator, Infusion Pump, Ultrasound Device, Generic Device and System Patient Monitor, Defibrillator, Infusion Pump, Ultrasound Device and Generic Device Patient Monitor, Defibrillator, Infusion Pump, Ultrasound Device and Generic Device Patient Monitor, Defibrillator,...

 Open the catalog to page 4
ESA615-5

Environmental Operating temperature Storage temperature Operating humidity 100/115 V ac mains supply voltage up to 5000 meters 230 V ac mains supply voltage up to 2000 meters Two-year extended warranty (no-cost, available after first-year calibration at any authorized Fluke Biomedical Service Center, otherwise standard one year warranty applies) Ordering information Models/descriptions 4132046 ESA615 US, 115 V with Ansur automation software ESA615 France/Belgium, 230 V with Ansur automation software ESA615 Europe, 230 V with Ansur automation software ESA615 Israel, 230 V with Ansur automation...

 Open the catalog to page 5
ESA615-6

Getting Started Guide, hard copy, multilingual Data Transfer Cable USA/AUS/ISR Accessory Kit: test lead set, TP1 test probe set, AC285 alligator clip set (ESA T/L kit, country-specific, see below) USA/NEMA outlet to NBR14136 socket (Brazil only) Null Post Adapter 5-to-5 Banana Jack to ECG (BJ2ECG) Adapter (ESA612-2016) Carrying Case LINE CORD Country-specific power cord Ansur ESA615 Plug-in Software (Ansur automation software versions only) Accessory kits (country specific) 3111008 3111024 USA/AUS/ISR Accessory Kit: test lead set, TP1 test probe set, AC285 alligator clip set (ESA T/L kit, USA)...

 Open the catalog to page 6
ESA615-7

About Fluke Biomedical Fluke Biomedical is the world’s leading manufacturer of quality biomedical test and simulation products. In addition, Fluke Biomedical provides the latest medical imaging and oncology qualityassurance solutions for regulatory compliance. Highly credentialed and equipped with a NVLAP Lab Code 200566-0 accredited laboratory, Fluke Biomedical also offers the best in quality and customer service for all your equipment calibration needs. Today, biomedical personnel must meet the increasing regulatory pressures, higher quality standards, and rapid technological growth, while...

 Open the catalog to page 7

Archived catalogs

  1. RAYSAFE 452

    9  Pages

  2. RaySafe X2

    12  Pages

  3. RaySafe DXR+

    2  Pages

  4. BP Pump 2

    82  Pages

  5. RaySafe Solo

    5  Pages

  6. DPM1B

    2  Pages

  7. INCU ?

    4  Pages

  8. 76-606DX

    2  Pages

  9. RaySafe Xi

    8  Pages

  10. VT305

    4  Pages

  11. ProSim

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.