Key Features:
  • The Impulse 7010 Defibrillator Selectable Load Accessory provides multiple load options (25 Ω to 200 Ω) compliant with IEC 60601-2-4 standards.
  • Compatible with various defibrillation technologies such as Lown, Edmark, trapezoidal, biphasic, and pulsed-biphasic.
  • Supports AED technology with high measurement accuracy (±1% of reading + 0.1 J).
  • Features an intuitive user interface, backlit display, portable design, and a long-lasting rechargeable battery.
  • Includes pacer brand selections and protection against defibrillator output (7000DP only).
  • Offers 10 independent ECG outputs for 12 lead combinations and flexible heart-rate settings.
  • DSP-based measurements allow for future firmware and waveform upgrades.
  • Comes with a two-year extended warranty and optional Ansur test automation software.
Technical Data:
  • The Impulse 6000D and 7000DP are precision test instruments for cardiac-resuscitation equipment, compatible with worldwide pulse shapes and AED technology.
  • The Impulse 7000DP includes tests for external transcutaneous pacemakers and a range of test loads and measurement algorithms.
  • Standard USB interface for computer control and data transfer, with optional Ansur PC-based automation software.
General Specifications:
  • Operating temperature: 10°C to 40°C; Storage temperature: -20°C to 60°C.
  • Humidity: 10% to 90% non-condensing; Display: LCD.
  • Power: Internal rechargeable NiMH battery with nine hours of operation after full charge.
  • Enclosure: ABS plastic housing; Dimensions: 32 cm x 24 cm x 13 cm; Weight: 3.02 kg.
  • Safety standards: CE, CAN/CSA, UL, C-Tick; EMC standards: European EMC.
Defibrillator Analyzer Technical Specifications:
  • Energy output measurement compatible with various defibrillator waveshapes.
  • Autoranged measurement from 0.1 J to 600 J with high accuracy.
  • Load resistance: 50 Ω with ±1% accuracy; Pulse trigger level: 20 V.
  • Voltage range: 20 V to 5000 V; Current range: 0.4 A to 100 A.
  • ECG normal sinus rates: 10 BPM to 360 BPM in 1 BPM steps.
Transcutaneous Pacemaker Analyzer Technical Specifications (7000DP only):
  • Test load selections with fixed and variable load options.
  • Current range: 4 mA to 250 mA; Pulse rate range: 5 PPM to 800 PPM.
  • Energy range: 1 µJ to 2 J with ±4% accuracy.
Impulse 7010 Defibrillator Selectable Load Accessory:
  • Maximum voltage: 5000 V; Maximum continuous power: 12 W.
  • Inductance varies with load settings; Temperature and humidity specifications provided.
Ordering Information:
  • Various models available for different regions including US, Schuko, UK, Japan, Australia, and India.
Product Overview: The document details the Impulse 7000DP Defibrillator/Transcutaneous Pacemaker Analyzer with test automation, available in various country-specific models including Schuko, UK, Japan, Australia, and India.
Standard Accessories: The analyzer comes with a USB Computer Communication Cable, User Manual CD, Getting-Started Guide, a country-specific Battery Eliminator, Carrying Case, and Defib Paddle Contact Plates.
Optional Accessories: Optional accessories include various defibrillator and pacer adapters compatible with brands like Medtronic, Kimberly Clark, Zoll Medical, Philips, and GE Marquette, as well as an Impulse 7010 Defibrillator Selectable Load Accessory.
Company Information: Fluke Biomedical, a leading manufacturer of biomedical test and simulation products, provides quality assurance solutions for medical imaging and oncology. The company is ISO 9001 certified and offers products that are CE Certified, NIST Traceable, and UL, CSA, ETL Certified where required.
Contact Information: Fluke Biomedical can be contacted in the USA at (800) 850-4608, in Europe/Middle East/Africa at +31 40 267 5435, and from other countries at +1 (440) 248-9300. Email: [email protected], Website: www.flukebiomedical.com.
Regulatory Commitment: Fluke Biomedical adheres to quality standards and certifications, ensuring their products meet regulatory compliance and high-quality standards.
See more

Catalog excerpts

Impulse 6000D/7000DP - 2013-1

Defibrillator/External Pacer Analyzer Technical Data The Impulse 6000D Defibrillator Analyzer and Impulse 7000DP Defibrillator/Transcutaneous Pacer Analyzer Test Systems are rugged, portable precision test instruments that ensure proper operation and ultimate performance of critical life-support cardiac-resuscitation equipment. The Impulse 6000D and Impulse 7000DP test capabilities encompass the spectrum of worldwideestablished pulse shapes, showcase breakthrough AED technology compatibility, and outperform in accuracy and standards. Additionally, the Impulse 7000DP incorporates the tests and the extensive range of test loads and measurement algorithms needed to test external transcutaneous pacemakers. In conjunction with an Impulse 7000DP, the Impulse 7010 Defibrillator Selectable Load Accessory provides multiple loads of 25 Ω, 50 Ω, 75 Ω, 100 Ω, 125 Ω, 150 Ω, 175 Ω, and 200 Ω for defibrillator performance testing. A standard USB interface enables computer control and data transfer, and optional Ansur PC-based automation software increases productivity by outfitting users with an easy-to-use method to standardize testing procedures and capture, print and document data. • Impulse 7010 Defibrillator Selectable Load Accessory provides multiple loads of 25 Ω, 50 Ω, 75 Ω, 100 Ω, 125 Ω, 150 Ω, 175 Ω, and 200 Ω to comply with IEC 60601-2-4 standard (optional) Lown, Edmark, trapezoidal, biphasic and pulsed-biphasic defibrillation technology compatibility • • AED technology compatibility • First-class measurement accuracy ± 1 % of reading + 0.1 J • Intuitive user interface and backlight, easy-to-read display • Portable, rugged, easy to carry • Long-lasting, rechargeable battery • Pacer brand selections • Pacer input protected against defibrillator output (7000DP only) • 10 independent ECG outputs that provide 12 lead combinations for standardized clinical signals • Flexible heart-rate settings (1 BPM step) facilitate rate meter accuracy and alarm testing • DSP-based measurements enable future firmware and waveforms upgrade • Unique integrated posts for secure connections • Two-year extended warranty (no-cost extended warranty available after first-year calibration at any Fluke Biomedical authorized service center) • Optional Ansur test automation software to standardize testing procedures, capture waveforms and test results, and print and document test results • Designed, tested, and built to incomparable Fluke quality standards

 Open the catalog to page 1
Impulse 6000D/7000DP - 2013-2

General specifications Operating temperature Storage temperature USB device port for computer control Modes of operation Manual and remote Internal rechargeable NiMH battery pack for nine hours (typical) operation after full charge or the battery charger can operate the analyzer and charge the battery simultaneously Battery charger 100 V to 240 V input, 15 V/1.5 A output. For best performance, the battery charger should be connected to a properly grounded ac receptacle Dimensions (WxDxH) Safety standards CE: IEC/EN61010-1 2nd Edition; Pollution degree 2 CAN/CSA-C22.2 No 61010-1; UL61010-1 C-Tick:...

 Open the catalog to page 2
Impulse 6000D/7000DP - 2013-3

ECG waves •  Normal sinus rhythm (NSR): 10 BPM to 180 BPM in 1 BPM steps •  Atrial fibrillation: Coarse and fine Monomorphic ventricular •  tachycardia: 120 BPM to 240 BPM in 5 BPM steps •  Asystole: Flat line Automated defibrillator test ECG waves Normal sinus: 10 BPM to 300 BPM in 1 BPM steps Ventricular fibrillation: Coarse and fine Monomorphic ventricular tachycardia: 120 BPM to 300 BPM in 5 BPM steps Polymorphic ventricular tachycardia: 5 types Asystole: Flat line Lead configuration: 12-lead simulation; RA, LL, LA, RL, V1-6 with independent outputs Lead to lead impedance: 1000 Ω (nominal)...

 Open the catalog to page 3
Impulse 6000D/7000DP - 2013-4

Arrhythmia selections Pacer interactive (7000DP only) • Demand: 30 BPM to 360 BPM in 1 BPM steps • Asynchronous • Non-capture • Non-function • Threshold (interactive pacing simulation only): 10 mA to 250 mA in 10 mA steps Supraventricular • Artrial fibrillation course • Atrial fibrillation fine • Atrial flutter • Sinus arrhythmia • Missed beat • Atrial tachycardia • Paroxysmal atrial tachycardia (PAT) • Nodal rhythm • Supraventricular tachycardia Premature • Atrial PAC • Nodal PNC • PVC1 left ventricle • PVC1 LV early • PVC1 LV R on T • PVC2 right ventricle • PVC2 RV early • PVC2 RV R on T •...

 Open the catalog to page 4
Impulse 6000D/7000DP - 2013-5

Transcutaneous pacemaker analyzer technical specifications (7000DP only) Test load Selections Defibrillator input Fixed load: 50 Ω Accuracy: ± 1 %, non-inductive (<2 µH) Power rating: 10 defib pulses of 360 J every 5 minutes Pacemaker input Variable load: 50 Ω to 1500 Ω in 50 Ω steps Accuracy: ± 2 %, non-inductive (< 2 µH) Power rating: 5 W (average), 40 W (peak) @ 1000 Ω Rate: 10 BPM to 300 BPM in 1 BPM steps Amplitude: 1 mV Underdrive rate: 10 BPM minimum Overdrive rate: 300 BPM maximum Sensitivity test Automatic interactive threshold detection Accuracy: ± 5 % of setting Amplitude: 0.05 mV...

 Open the catalog to page 5
Impulse 6000D/7000DP - 2013-6

Impulse 7010 Defibrillator Selectable Load Accessory General specifications Maximum voltage 5000 V Maximum continuous power 12 W, equivalent to 10 defib pulses of 360 J every 5 minutes Inductance < 2 µH, @25 Ω < 3 µH, @50 Ω < 4 µH, @75 Ω and 100 Ω < 5 µH, @125 Ω < 6 µH, @150 Ω < 7 µH, @175 Ω < 8 µH, @200 Ω Temperature Operating: 10 °C to 40 °C (50 °F to 104 °F) Storage: -20 °C to 60 °C (-4 °F to 140 °F) Calibration interval One-year Electrical specifications (for Load Accessory and Analyzer together) Safety class Complies with EN61010-1 2nd Edition, Class II product Safety and EMC marks N10140...

 Open the catalog to page 6

Archived catalogs

  1. RAYSAFE 452

    9  Pages

  2. RaySafe X2

    12  Pages

  3. RaySafe DXR+

    2  Pages

  4. BP Pump 2

    82  Pages

  5. RaySafe Solo

    5  Pages

  6. DPM1B

    2  Pages

  7. INCU ?

    4  Pages

  8. 76-606DX

    2  Pages

  9. RaySafe Xi

    8  Pages

  10. VT305

    4  Pages

  11. ProSim

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.