ProSim 3 and 2 - 1

Technical data ProSim 3 and 2 Vital Signs Simulators Don’t need a comprehensive patient monitor tester? The 6-in-1 ProSim 3 and 4-in-1 ProSim 2 Vital Signs Simulators are clear choices for biomedical engineers and field service technicians that need a quality, feature-rich device with high portability. Choose one of these modern vital signs simulators for preventive maintenance, troubleshooting and repair. The ProSim 3 and 2 feature the perfect amount of features for testing in the field. We like to call it the Just Right feature set, and it includes: • • • • • • • • ECG Pacemaker Arrhythmia and performance testing Respiration Invasive blood pressure Temperature Cardiac output (ProSim 3 only) Fetal/maternal (ProSim 3 only) Key features • Portable, for evaluating the performance of patient monitors in the field • 20 % lighter and 25 % smaller than preceding technology • Just Right feature set includes: ECG, pacemaker, arrhythmia and performance testing, respiration, invasive blood pressure, temperature, cardiac output (ProSim 3 only), fetal/maternal (ProSim 3 only) • 43 high-quality waveforms • With four IBP channels, ProSim 3 tests even the highest acuity scenarios • Stay-connected ECG posts for secure lead connections • Improved user interface and online Advantage Training demos • Upgraded DIN connectors ensure consistency with the ProSim family; minimize cable compatibility issues • Field upgradeable, and easily paired with other devices for comprehensive testing • ProSim

Open the catalog to page 1
ProSim 3 and 2 - 2

Specifications General specifications Temperature Dimensions (LxWxH) USB device upstream port Battery life 8 hours continuous operation Safety standards Detailed specifications Normal-sinus-rhythm waveform ECG Reference The ECG amplitudes specified are for Lead II (calibration), from the baseline to the peak of the R wave. All other leads are proportional. Normal sinus rhythm 12-lead configuration with independent outputs referenced to right leg (RL). Output to 10 universal ECG Jacks, color-coded to AHA and IEC Standards Amplitude accuracy ± 2 % of setting Lead II. All other leads ± 5 %...

Open the catalog to page 2
ProSim 3 and 2 - 3

Specifications continued Paced arrhythmias Atrial 75 BPM Asynchronous 75 BPM Demand with frequent sinus beats Demand with occasional sinus beats Atrio-ventricular sequential Noncapture (one time) Nonfunction Power-on default Left focus, standard timing (except where specified) Supraventricular arrhythmia Atrial fibrillation (coarse or fine); atrial flutter sinus arrhythmia; missed beat (one time); atrial tachycardia; paroxysmal atrial tachycardia; nodal rhythm; and supraventricular tachycardia Premature arrhythmia (All one-time events) Premature atrial contraction (PAC); premature nodal...

Open the catalog to page 3
ProSim 3 and 2 - 4

Specifications continued Fetal/Maternal ECG (ProSim 3 only) Fetal heart rate (Fixed) Fetal heart rate (IUP) 140 BPM at beginning, then varies with pressure Intrauterine-pressure waveforms Early deceleration, late deceleration, and uniform acceleration Wave duration 90 seconds, bell-shaped pressure curve, from 0 to 90 mmHg and returning to 0 Power-on default FHR 120 BPM, early deceleration, manual Invasive blood pressure Channels 4, each independently settable with identical parameters and are individually electronically isolated from other signals Input/output impedance Exciter input range...

Open the catalog to page 4
ProSim 3 and 2 - 5

Specifications continued Respiration Rate Ratio (inspiration: expiration) 0.2, 0.5, 1 or 3 Ω peak-to-peak variation of lead impedance Accuracy delta Accuracy baseline Respiration lead Apnea selection OFF, 12, 22 or 32 seconds (one-time events), or continuous (Apnea ON = respiration OFF) Power-on default 20 BrPM, delta 1.0 Ω, 1000 Ω baseline Temperature Temperature Yellow Springs, Inc. (YSI) Series 400 and 700 Output connector Power-on default Cardiac output (ProSim 3 only) Catheter type Calibration coefficient Blood temperature Injectate volume Injectate temperature Cardiac output...

Open the catalog to page 5
ProSim 3 and 2 - 6

Ordering information Item numbers/Descriptions ProSim 3 ProSim Vital Signs Simulator ProSim Vital Signs Simulator Standard accessories ProSim 2/3 Instruction Sheet (multi-language) 614487 Two 9-volt alkaline batteries (minimum 8 hours continuous use) 3010-0289FG, CI-3 Cable Assembly (Cardiac Output Box; ProSim 3 only) ProSim 2/3 Carrying Case AC/DC Power Supply AC Power Cord (Schuko) AC Power Cord (Australia) AC Power Cord (Denmark) AC Power Cord (India) AC Power Cord (Israel) AC Power Cord (Italy) AC Power Cord (Switzerland) Cardiac output switch for GE ProSim 3 and 2 Vital Signs Simulators

Open the catalog to page 6
ProSim 3 and 2 - 7

About Fluke Biomedical Fluke Biomedical is the world’s leading manufacturer of quality biomedical test and simulation products. In addition, Fluke Biomedical provides the latest medical imaging and oncology quality-assurance solutions for regulatory compliance. Highly credentialed and equipped with a NVLAP Lab Code 200566-0 accredited laboratory, Fluke Biomedical also offers the best in quality and customer service for all your equipment calibration needs. Today, biomedical personnel must meet the increasing regulatory pressures, higher quality standards, and rapid technological growth,...

Open the catalog to page 7

All Fluke Health Solutions catalogs and technical brochures

  1. ESA612

    6 Pages

  2. PS320

    5 Pages

  3. 190M

    8 Pages

  4. ESA615

    7 Pages

  5. IDA-6 Flyer

    1 Pages

  6. 451B

    3 Pages

  7. 451P

    3 Pages

  8. ProSim 4

    6 Pages

Archived catalogs

  1. RAYSAFE 452

    9 Pages

  2. RaySafe DXR+

    2 Pages

  3. BP Pump 2

    82 Pages

  4. RaySafe Solo

    5 Pages

  5. DPM1B

    2 Pages

  6. INCU ?

    4 Pages

  7. 76-606DX

    2 Pages

  8. RaySafe Xi

    8 Pages

  9. RaySafe X2

    12 Pages

  10. VT305

    4 Pages

  11. ProSim

    8 Pages