RaySafe Solo Specifications
Open the catalog to page 1
RAYSAFE SOLO GENERAL EXPOSURE NEEDED One RESET Automatic DETECTOR CABLE LENGTH 2 and 10 m (6.5 and 33 ft) PATENT Germany DE69430268.6-08 SIZE BASE UNIT WEIGHT POWER OFF POWER SOURCE BATTERY TIME READ OUT Rechargeable 7.4 V Li-on battery 201 - 401hours (depending on detector and if Bluetooth is used) Three row alphanumerical backlit display with four digits numerical resolution RANGE mA UNCERTAINTY mA RANGE mAs UNCERTAINTY mAs MAX LOAD REPRODUCIBILITY OVER VOLTAGE PROTECTION EXPOSURE TIME RANGE UNCERTAINTY PULSE RANGE PEAK TRIG LEVEL PULSE RATE RANGE mAs PER PULSE RANGE SIZE...
Open the catalog to page 2
RAYSAFE SOLO DOSE SIZE DETECTOR WEIGHT DOSE (R/F LOW) RANGE TRIG LEVEL SIZE DETECTOR WEIGHT RANGE TRIG LEVEL UNCERTAINTY DOSE (R/F HIGH) RANGE TRIG LEVEL RANGE MIN. PEAK TRIG LEVEL UNCERTAINTY 10 nGy/s –1 mGy/s (70 µR/min – 7 R/min) MIN. PEAK TRIG LEVEL RANGE MIN. PEAK TRIG LEVEL UNCERTAINTY RANGE UNCERTAINTY PEAK TRIG LEVEL (DENT LOW) PEAK TRIG LEVEL (DENT HIGH) 10 % or ± 0.2 mm Al (at signal levels above 1/1000 of max dose rate for selected sensor) 2 % (for total filtrations from 2.5 mm Al up to 15 mm Al or equivalent, Active Compensation) 0.8 mA, 70 kV, 50 cm (19.7 in), no added filtration...
Open the catalog to page 3
RAYSAFE SOLO LIGHT SIZE DETECTOR 117 x 22 x 12 mm WEIGHT DOSE BEAM QUALITITES RANGE TRIG LEVEL UNCERTAINTY Mo/Mo, Mo/Al, Mo/Rh, Rh/Rh, Rh/Al, W/Rh, WAg 5 pGy - 9999 Gy (0.5 mR - 9999R) 10 pGy/s (70 mR/min) 5 % or ± 5 pGy (0.5 mR) (20 - 40 kV: Mo/Mo 22 - 49 kV: Mo/Al, Rh/Rh, Rh/Al 22 - 40 kV: Mo/Rh, W/Rh, W/Ag, 0 - 2.5 mm Al added filtration, Active Compensation:' (1) Definition: Paddle = 0.1 mm Al Note! Variation in paddle thickness and homogeneity may affect kV results. To achieve the most accurate result, kV measurements without paddle is recommended. (2) HVL is an option to RaySafe...
Open the catalog to page 4
RAYSAFE UNCERTAINTY DEFINITION The expanded uncertainty is stated as the combined uncertainty of measurement multiplied by the coverage factor k=2, which assuming a normal distribution has a coverage probability of 95 % (complies with GUM by ISO (1995, ISBN 92-67-10188-9)). Instrument specifications are subject to purchased configuration. All specifications may change without not
Open the catalog to page 5All Fluke Health Solutions catalogs and technical brochures
-
ESA612
6 Pages
-
PS320
5 Pages
-
Impulse 6000D/7000DP
15 Pages
-
190M
8 Pages
-
ESA615
7 Pages
-
Gas flow analyzer
2 Pages
-
ProSim 3 and 2
7 Pages
-
Product catalog
40 Pages
-
IDA-6 Flyer
1 Pages
-
ProSim SPOT Light
4 Pages
-
VT900A Datasheet
6 Pages
-
VT900A + VAPOR
7 Pages
-
ESA614 Datasheet
6 Pages
-
Gas Flow Family Brochure
2 Pages
-
451B
3 Pages
-
451P
3 Pages
-
ProSim 4
6 Pages
Archived catalogs
-
QA-ES Series II
4 Pages
-
RAYSAFE 452
9 Pages
-
451P Ion Chamber Survey Meter
30 Pages
-
RaySafe Dose Viewer
10 Pages
-
RaySafe DXR+
2 Pages
-
BP Pump 2
82 Pages
-
Electrical Safety Analyzers
8 Pages
-
RaySafe Solo
5 Pages
-
DPM1B
2 Pages
-
SigmaPace™ 1000
8 Pages
-
965 Stack Monitor
3 Pages
-
INCU ?
4 Pages
-
76-606DX
2 Pages
-
07-CRXW and 07-QRX
4 Pages
-
RaySafe Xi
8 Pages
-
RaySafe X2
12 Pages
-
Impulse 6000D/7000DP - 2013
8 Pages
-
VT305
4 Pages
-
ProSim
8 Pages