1. Catalogs
  2. Forest Medical
  3. Trillium Platinum

Trillium Platinum

Trillium Platinum

Trillium Platinum

Product catalog summary
Overview: The document introduces the Trillium Platinum Holter Analysis Software, an advanced tool for heart rate variability analysis. It builds on the features of the Trillium Gold software, adding frequency domain heart rate variability (HRVf) analysis, a database interface module, and enhanced capabilities for Holter analysis.
Key Features:
  • HRVf Analysis: Modeled after standards from the European Society of Cardiology and the North American Society of Pacing and Electrophysiology, it includes long and short-term calculations and power spectral analysis.
  • Database Interface: The Trillium Explorer Database Interface Module allows Holter files to be converted to a database format for further analysis and reporting.
  • Holter Recorders Compatibility: Compatible with Trillium 2000, 3000, 4000, and 5000 Holter Recorders, offering an expandable and upgradable system.
  • Advanced Analysis: Includes advanced paced beat analysis, frequency and time domain heart rate variability analysis, and Q-T and R-R interval measurements.
  • Reporting and Editing: Offers customizable reports, narrative summaries, and editing capabilities for report strips and episodes.
Technical Specifications:
  • Software Requirements: Compatible with Windows 98SE, 2000, or XP, requiring a minimum of 150 MHz PII processor, 32 MB memory, and 100 MB hard disk space.
  • Output Options: Supports PDF, fax, and electronic medical records, with capabilities for ASCII data output and bitmap graphs.
Contact Information: Forest Medical, LLC, located in East Syracuse, NY, provides contact details for inquiries and support.
See more

Catalog excerpts

Trillium Platinum-1

Advance to the Next Level Advanced Technology Accurate and Reliable Analysis Frequency Domain Heart Rate Variability Analysis Flexible Reporting Proven eidos™ Holter Algorithm Advanced Paced Beat Analysis and Reporting Database Interface Capability Choice of Holter Recorders Print, Fax, and PDF Reports Customizable Leasing Programs Turnkey Systems Available Our Trillium Platinum Holter Analysis Software provides all of the features of our Trillium Gold™ software while adding Frequency Domain Heart Rate Variability (HRVf) analysis and reporting, our Trillium Explorer™ Database Interface Module, and additional capabilities. Now your practice can advance to the next level of Holter analysis with software that is both powerful and easy to use. Add HRVf Analysis to Your Practice Narrative Summary Our HRVf analysis is modeled after the European Society of Cardiology and the North American Society of Pacing and Electrophysiology Task Force’s Standards of Measurement, Physiological Interpretation and Clinical Use for Heart Rate Variability. It includes both long and short term calculations and power spectral analysis in user programmable ranges and windowing schemes. Make Maximum Use of Your Data Our Trillium Explorer Database Interface Module allows any set of Holter files to be queried and converted to a database file format (mdb) for subsequent analysis and reporting by database programs. This allows sets of Holter studies to be reviewed and sorted or screened for characteristics included in cover page or narrative summary data. Full Disclosure 60 Seconds Discover the Value Leader in Holter Trillium Platinum can be used with our Trillium 2000™, Trillium 3000™, Trillium 4000™, or Trillium 5000™ Holter Recorders to form an advanced Holter Monitoring System. Trillium Platinum based systems are easily and economically expandable with multiple recorders and workstations and are fully upgradable as new developments arise. Choose Forest Medical products for the best long term value in Holter monitoring technology. Call Forest Medical Call us today for a no obligation analysis of your Holter monitoring requirements. Forest Medical, LLC • 6700 Old Collamer Road • East Syracuse, NY 13057 Phone: 800-844-2037 • 315-434-9000 • Fax: 315-432-8064 [email protected] • www.forestmedical.com Printed in U.S.A. Copyright © 2007 by Forest Medical, LLC. All rights reserved.

 Open the catalog to page 1
Trillium Platinum-2

Overview • 32 Bit Windows® Application • Point and click, web browser-like operation • Each report page is displayed on screen • Color-coded arrhythmias • Color-coded pacer spikes • No limit to number of patient files that can be stored on disk • PDF Report output • On-screen help, tutorial, and hints Analysis Algorithm • Forest Medical eidos™ Holter Algorithm • Adjustment for Atrial Fibrillation / Irregular Rhythm sensitivity • High Heart Rate analysis capability (Sustained rates up to 320 BPM) Advanced Paced Beat Analysis / Reporting • Single and dual chamber pacemaker spike and paced beats...

 Open the catalog to page 2

All Forest Medical catalogs and technical brochures

  1. Trillium Gold

    2  Pages

  2. TSliverDS

    2  Pages

  3. T5000DS

    1  Page

  4. T4000DS

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.