Contact Information: Forme Medical Pty Ltd is located at 11 Frankston Gardens Drive, Carrum Downs, Victoria 3201, Australia. Phone: 03 9708 2661. Website: www.formemedical.com.au.
Introduction: The AMC 2100 Series manual offers guidance on operating and maintaining the medical couch, stressing supervision around children and proper use to prevent injury and warranty issues.
Safety Instructions: All personnel must read the manual before use and keep it accessible. Ensure the area around the couch is clear of obstructions and all connections are secure and undamaged.
Important Warnings: Only qualified practitioners should operate the couch, which is designed for one person with a maximum lift capacity of 200kg. Avoid placing heavy objects on the edges and ensure cables are not damaged. The couch is not intended for patient transportation, and the maximum ramp slope is 15 degrees.
Getting Started: The couch arrives fully assembled. Remove packaging carefully without sharp objects. Connect the hand or foot switch and plug into a 240VAC socket. For AMC 2130 or 2140, remove the packing strap before use.
Operation: The couch operates on 24 volts DC with electric actuators. Ensure power leads are not caught in the lifting mechanism. It is designed for average weight distribution.
Wheels and Locking: The couch features four 125mm wheels for movement. Ensure wheels are locked before use by tilting the red section on each wheel.
Control Switch Operation: Options include a hand or foot switch with buttons for functions like raising/lowering the couch, backrest, and leg rest adjustments.
Optional Features: Includes back cushion, Trendelenburg tilt, battery pack, breathe hole and plug, head cushion, Heine light, paper roll holder, swivel armrest, and white LED light.
Care and Maintenance: Regular cleaning and maintenance are essential. Check for faults and ensure the vinyl and frame are in good condition.
Technical Specifications and Warranty: Detailed specifications and warranty information are provided to ensure proper use and longevity of the product.
See more

Catalog excerpts

2100 Series-1

AMC 2100 Series —I Forme Medical

 Open the catalog to page 1
2100 Series-2

CONTACT US: Forme Medical Pty Ltd 11 Frankston Gardens Drive, Carrum Downs, Victoria 3201 AUSTRALIA Phone: 03 9708 2661 Web: www.formemedical.com.au ABN: 48 154 618 014 │ ACN: 154 618 014 January

 Open the catalog to page 2
2100 Series-3

Product Manual – AMC 2100 Series Thank you for purchasing from Forme Medical! We hope you enjoy your new couch and find that it has all the functionality you need. Our industry leading warranties mean we will be here to support you for the life of your couch, if there is anything you need or if you have any issues. We are also very happy to chat to you about the research and development of any new products, or customisations to our current products. So please stay in...

 Open the catalog to page 3
2100 Series-4

Product Manual – AMC 2100 Series

 Open the catalog to page 4
2100 Series-5

Product Manual – AMC 2100 Series

 Open the catalog to page 5
2100 Series-6

Product Manual – AMC 2100 Series Safety Instructions The primary concern of Forme Medical is that our products are operated within safe parameters and regularly maintained to ensure the safety of both patients and practitioners. • Please ensure that relevant personnel read this manual in full before attempting to install or operate the examination couch. • Please keep this manual near the couch or, if possible, permanently attached to it. • Before using or operating your...

 Open the catalog to page 6
2100 Series-7

Product Manual – AMC 2100 Series IMPORTANT WARNINGS 1. This device is to be operated by a qualified practitioner only. 2. This couch is designed to carry one person only. 3. Maximum total lift capacity is 200kg. 4. Do not sit, or place heavy objects on the edge of either end of the device, as it may cause the couch to become unstable. 5. Take care to avoid the power leads and control leads getting caught in the lifting mechanism. Regularly check these items for damage. 6. Do...

 Open the catalog to page 7
2100 Series-8

Product Manual – AMC 2100 Series Get started Unpacking and installing Your new medical couch will arrive fully assembled and ready to plug in to start operation. WARNING: Carefully remove wrapping without the use of knives or sharp objects to avoid the risk of damaging the upholstery. If you see any damage or issues with the couch before you use it, contact us immediately. To install: 1. Plug in the hand or foot switch if it is not already connected by inserting the plug...

 Open the catalog to page 8
2100 Series-9

Product Manual – AMC 2100 Series Operation Our couches are all fully electric, with main movements completed with the assistance of electric actuators. To protect people from injury, the couch operates on 24 volts direct current. WARNING: Take care to avoid the power leads and control leads getting caught in the lifting mechanism. Also, regularly check these items for damage. Do not use electric cables with damaged insulation. Our couches are designed for average weight...

 Open the catalog to page 9
2100 Series-10

Product Manual – AMC 2100 Series To release the lock simply push the high end of the red section so that it returns to a flat position. LOCKED Ensure that all four wheels are locked to ensure stability before allowing patients onto the couch and before operating the couch. Control switch operation You have the option of either a hand switch or foot switch for the operation of your medical couch. Each control will have a combination of either four, six or eight...

 Open the catalog to page 10
2100 Series-11

Product Manual – AMC 2100 Series Press the button for the function you require and the direction you need the couch to move. The couch will continue to move for as long as the button is being pressed. The couch will stop at its limit in either direction. Foot switch control The top row of buttons control upward adjustment, while the bottom row controls lowering adjustment. Each section is then split into a pair for each function. Top row controls upward movement...

 Open the catalog to page 11
2100 Series-12

Product Manual – AMC 2100 Series Operation of optional extras and product specific features Back cushion The back cushion is used to provide extra support and comfort to patients and also help with positioning. Follow the same care instructions for the cushion as for the vinyl on the couch (refer to page 25) Backwards couch tilt -­‐ Trendelenburg (optional for AMC 2110, AMC 2130, AMC 2140) Trendelenburg allows the whole couch to be tilted backwards (backrest down) on a...

 Open the catalog to page 12
2100 Series-13

Product Manual – AMC 2100 Series Battery Pack You must charge the battery for 24 hours before its first use. The battery pack can be used to power the couch during operation, for instance if the couch is moved frequently and the operator does not want to connect and disconnect the power lead. It should be charged when the couch is not in use. Alternatively the battery pack can be used for emergency power back-­‐up. When mains power is disconnected the system will automatically...

 Open the catalog to page 13
2100 Series-14

Product Manual – AMC 2100 Series Breathe hole and plug Please keep the plug in the breathe hole when it is not in use. To remove the plug, simply push it upwards from the back of the couch. To reinsert the plug, push it back into the breathe hole and ensure it holds securely. Head cushion The head cushion comes with a Velcro grip that attaches it to the back of the couch. Follow the same care instructions for the cushion as for the vinyl on the...

 Open the catalog to page 14

All Forme Medical catalogs and technical brochures

  1. Argon AMC 1020

    12  Pages

  2. 2500 Series

    30  Pages

  3. OPAL

    2  Pages

  4. SAPPHIRE

    2  Pages

  5. MALACHITE

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.