emotion tecar-1

BEYOND HEAT Therapeutic Effectiveness Repeatability Safety www.fremslife.com

 Open the catalog to page 1
emotion tecar-2

THERAPEUTIC EFFECTIVENESS beyond heat Exploiting heat for therapeutic purposes is common to all the tecartheraphy devices, included. However, the biostimulation of tissues, fundamental for the therapeutic effectiveness of this method, is not only linked to heat, but also to the exposure of the tissues to an electromagnetic field which is able to interact with the cells and their metabolism. To this purpose a voltage higher than 100 V is required and, in order to penetrate the cellular membrane, it must be modulated with frequencies of the order of hundreds of KHz. With conventional Tecar, when...

 Open the catalog to page 2
emotion tecar-3

REPEATABILITY of the treatment and Therapeutic Dose Aside from the constant tension, specific to the PWM modulation, Emotion Tecar also ensures that the mean electric current is constant throughout the application. This ensures the control of the power delivered to the patient (THERAPEUTIC DOSE) and provides a further security check against potentially dangerous electrical current values. CONTINUOUS CONTROL OF THE PARAMETERS Particular care has been paid to the shield of the device, the electrodes and relevant cables, in order to assure the safety of the operator in respect to the The electronics...

 Open the catalog to page 3
emotion tecar-4

STATIC ELECTRODES Thanks to the technology that assures the above performance, allows static electrodes to be applied safely. It is possible to carry out treatments which are operator independent and increase the productivity of the Centre, reducing the time spent by the operator next to the patient. It is possible to carry out treatments on the spinal column with the patient in supine position, particularly indicated in acute conditions It is possible to carry out a complementary treatment between manual therapy, both active and passive, and the instrumental therapy

 Open the catalog to page 4
emotion tecar-5

SPORT MEDICINE • Osteoarticular pathologies • Shoulder, ankle, knee, spine • Painful pathologies • Arthrosis and lower back pain • Muscle oxygenation • Post-race recovery (lactic acid removal and other build-up from the muscle) • Quick elimination of contractures • Particularly suitable in the treatment of sprains, strains, tendinitis, capsulitis, bursitis, pubalgia, haematoma, oedema, meniscal and ligament injuries, distortions, dislocations and fractures MANUAL THERAPY AND OSTEOPATHY POST-SURGICAL REHABILITATION • Re-absorption of oedema • Pain reduction • Improvement of wounds and scars •...

 Open the catalog to page 5
emotion tecar-6

SQUARE WAVE DUTY CYCLE ON (Pulse Width Modulation) it is a square wave with constant repetition frequency and variable duration (duty cycle) that makes it possible to control, with extreme precision, the power absorbed by an electric load (the treated tissues), varying (modulating) the duty cycle. ecar devic nal T es o nti To increase ve the power, resistance (of the tissues) being equal, it is required to Increase the voltage applied, but the biological response of the tissues varies with the voltage, which should be kept constant. Furthermore, the increase in voltage leads to an increase in...

 Open the catalog to page 6
emotion tecar-7

The PWM TECHNOLOGY drastically reduces power dissipation, thus allowing the generation of heat to be kept in check at an acceptable level for the patient, without limiting the average power delivered. In this way, by controlling the heat input associated with the biostimulation effect, which is always there,the operator can selectively promote the vasomotor phenomena which are secondary to thermal input, maximizing interaction with the tissues and the therapeutic effect. Thus, “cold stimulation” treatments are possible alongside traditionally thermal ones. PEMF TECHNOLOGY (Pulsed Electro Magnetic...

 Open the catalog to page 7
emotion tecar-8

Power Supply 4 - neutral - dynamic electrodes (res/cap) - static electrodes (res/cap) with automatic identification Working Frequencies Output Power Power setting (duty cycle) Check of output current parameters, patient electrode contact, system abnormalities, causing automatic discontinuation of treatment upon exceeding safety limits Colour Touch Display FUNCTIONAL FEATURES • Instantaneous power measurement • Instantaneous impedance measurement • Duty Cycle Control: 5-100%, 1% steps • PEMF (Pulsed Electro Magnetic Field) Mode • Phase Lock Mode • Automatic protocols of use and customizable programs....

 Open the catalog to page 8