Catalog excerpts
Single-use Ventilator Breathing Systems Easy, safe, hygienic + Simple handling, fast application for utmost patient safety + Effective heating system prevents rainout + Sterile packaging for optimal hygiene
Open the catalog to page 1Perfectly matched with STEPHAN Ventilator Breathing Systems – Patient Safety First! Ever increasing requirements to clean and sterilize reusable medical products lead to rising costs for hygienic reconditioning. A safe and economic alternative: single-use ventilation breathings sets by Fritz Stephan GmbH. They are available in three versions (P1, P3 and P7), complementing all STEPHAN pediatric ventilators. Perfect Combination Our single-use ventilator breathing sets have been developed specifically for ventilators STEPHANIE, SOPHIE, CHRISTINA and F120. The breathing tubes have been matched...
Open the catalog to page 2Ventilator breathing system for CHRISTINA Ventilator breathing system for STEPHANIE and SOPHIE 13
Open the catalog to page 3By connecting the enclosed pressure sensing line, the breathing set is immediately ready for use with ventilator CHRISTINA. The proximal port remains closed as only one temperature sensor is used. The additionally available adaptor allow the application of NO into the breathing tube. Re-usable Sensors and Lines Cost intensive components (such as temperature sensors and the breathing tube heating‘s electrical connections) which are not in direct contact with the patient, can be detached and re-used after a disinfecting wipe. These components can be ordered individually when required, as can...
Open the catalog to page 4Perfectly matches the intelligent heating and humidifying control system of STEPHANIE and SOPHIE: internal heating wires and a completely heated expiratory limb effectively reduce the rain out in the breathing tube, thus helping the optimal conditioning of patient respiratory air. The electrical connection lines are reusable. Digital One for all: the enclosed pressure sensing line facilitates the use of the breathing set, also with older „digital“ STEPHANIE units. For this, the pressure sensing line is simply attached to the Y-piece, for STEPHANIE version III this port remains closed
Open the catalog to page 5Fritz Stephan GmbH Medizintechnik Kirchstraße 19 56412 Gackenbach Germany Single-use Ventilator Breathing Systems Product overview P1 for F120 Article Single-use ventilator breathing tube P1 Adaptor cable breathing tube heating P1 Adaptor cable breathing tube heating P1 „F120 Dräger“ Single-use ventilator breathing tube P3/P7 including pressure sensing lines for P3 and P7 and NO analysis adaptor Adaptor cable breathing tube heating P3/P7 Temperature sensor P3 P7 for STEPHANIE and SOPHIE Single-use ventilator breathing tube P3/P7 including pressure sensing lines for P3 and P7 and NO analysis...
Open the catalog to page 6All Fritz Stephan catalogs and technical brochures
-
EVE_NEO
6 Pages
-
EVA_Neo
6 Pages
-
FSO2-Systems
8 Pages
-
SpaceSuit
2 Pages
-
EVE
8 Pages
-
Akzent X Color
8 Pages
-
Christina
3 Pages
-
Sophie
4 Pages
-
VentSafe
2 Pages
-
NGM 1000
2 Pages
-
Portec
3 Pages
-
EasyFlow nCPAP
6 Pages
-
F 120 mobil
3 Pages
-
Artec
3 Pages
-
Akzent Color
7 Pages
-
F 120
3 Pages
Archived catalogs
-
MedAir
3 Pages
-
Alia
3 Pages
-
NeoSID Nova
3 Pages
-
Stephanie
7 Pages