1. Catalogs
  2. Fritz Stephan
  3. Single-use Ventilator Breathing Systems
video corpo

Single-use Ventilator Breathing Systems

Single-use Ventilator Breathing Systems

Single-use Ventilator Breathing Systems

Product catalog summary
Overview
The document provides a comprehensive overview of single-use ventilator breathing systems by Fritz Stephan GmbH, specifically designed for pediatric use. These systems are compatible with various STEPHAN ventilators, including models like STEPHANIE, SOPHIE, CHRISTINA, and F120. The systems are available in three versions: P1, P3, and P7, each tailored for specific ventilator models.
Specifications
The breathing systems feature internal heating wires and a fully heated expiratory limb to minimize condensation, ensuring optimal respiratory air conditioning. They are suitable for both invasive and non-invasive ventilation, making them ideal for emergency and transport scenarios. The system includes a pressure sensing line for older StePhanie units and specific instructions for version iii. Single-use ventilator breathing tubes are available for different models with corresponding article numbers.
Components and Accessories
The document lists components and accessories such as single-use ventilator breathing tubes, adaptor cables for heating, temperature sensors, and NO dosage adaptors. These components are designed for easy connection and are available in sterile packaging to ensure hygiene and prevent cross-infections. Temperature sensors are specified for P3 and P7 models, and accessories are compatible with all tube systems.
Reusability and Cost Efficiency
Reusable components like temperature sensors and electrical connections can be detached, disinfected, and reused, reducing waste and costs. The systems eliminate the need for reconditioning, allowing medical staff to focus more on patient care.
Quality and Safety
The breathing systems are manufactured under strict quality standards using ecologically non-hazardous materials. They are latex-free and comply with DIN EN ISO 10993 standards, ensuring safety and comfort for pediatric patients.
Procedures and Recommendations
The document emphasizes simple handling and fast application to ensure patient safety. An effective heating system is recommended to prevent rainout, and sterile packaging is advised for optimal hygiene.
Conclusion
Fritz Stephan GmbH's single-use ventilator breathing systems offer a safe, hygienic, and cost-effective solution for pediatric ventilation needs, emphasizing patient safety and ease of use.
See more

Catalog excerpts

Single-use Ventilator Breathing Systems-1

Fritz Stephan GmbH Medizintechnik Kirchstraße 19 56412 Gackenbach Germany Single-use Ventilator Breathing Systems Easy, safe, hygienic + Simple handling, fast application for utmost patient safety + Effective heating system prevents rainout + Sterile packaging for optimal hygiene Single-use Ventilator Breathing Systems Product overview P1 for F120 Article Adaptor cable breathing tube heating P1 Adaptor cable breathing tube heating P1 „GT 500“ Perfectly matches the intelligent heating and humidifying control system of StePhanie and SoPhie: internal heating wires and a completely heated expiratory limb effectively reduce the rain out in the breathing tube, thus helping the optimal conditioning of patient respiratory air. the electrical connection lines are reusable. Single-use ventilator breathing tube P1 Article number Single-use ventilator breathing tube P3/P7 including pressure sensing lines for P3 and P7 and NO analysis adaptor Adaptor cable breathing tube heating P3/P7 P7 for STEPHANIE and SOPHIE Article Adaptor cable breathing tube heating P3/P7 Accessories for all tube systems Article Article number NO dosage adaptor Heating element for PNT incl. connecting hose Digital one for all: the enclosed pressure sensing line facilitates the use of the breathing set, also with older „digital“ StePhanie units. For this, the pressure sensing line is simply attached to the Y-piece, for StePhanie version iii this port remains closed. Exception PNT Heating the patient’s saturated exhaled air at the proximal side of the flow sensor (Pnt) can be accommodated by using the newly available Pnt heating. Warm air from the ventilator breathing set circulates around the Pnt housing avoiding thermal bridges which crucially contribute to increased condensate build-up. Technical changes without notice! Fritz Stephan GmbH 11/2013 Single-use ventilator breathing tube P3/P7 including pressure sensing lines for P3 and P7 and NO analysis adaptor

 Open the catalog to page 1
Single-use Ventilator Breathing Systems-2

Perfectly matched with STEPHAN Ventilator Breathing Systems – Patient Safety First! By connecting the enclosed pressure sensing line, the breathing set is immediately ready for use with ventilator ChriStina. the proximal port remains closed as only one temperature sensor is used. the additionally available adaptor allow the application of no into the breathing tube. l) P r S ress oP ure hi e a sen nd sing ST eP line ha 21 ni cm e, an alo g For primary care and during transport: the sterile single-use ventilator breathing sets for emergency and transport ventilators F120 (a, B and mobile) are...

 Open the catalog to page 2
Single-use Ventilator Breathing Systems-3

Perfectly matched with STEPHAN Ventilator Breathing Systems – Patient Safety First! By connecting the enclosed pressure sensing line, the breathing set is immediately ready for use with ventilator ChriStina. the proximal port remains closed as only one temperature sensor is used. the additionally available adaptor allow the application of no into the breathing tube. For primary care and during transport: the sterile single-use ventilator breathing sets for emergency and transport ventilators F120 (a, B and mobile) are swiftly and safely connected and are easily disposed of after use. The single-use...

 Open the catalog to page 3
Single-use Ventilator Breathing Systems-4

Perfectly matched with STEPHAN Ventilator Breathing Systems – Patient Safety First! By connecting the enclosed pressure sensing line, the breathing set is immediately ready for use with ventilator ChriStina. the proximal port remains closed as only one temperature sensor is used. the additionally available adaptor allow the application of no into the breathing tube. ) P r S ress oP ure hi e a sen nd sing ST eP line ha 21 ni cm e, an alo g For primary care and during transport: the sterile single-use ventilator breathing sets for emergency and transport ventilators F120 (a, B and mobile) are swiftly...

 Open the catalog to page 4
Single-use Ventilator Breathing Systems-5

Fritz Stephan GmbH Medizintechnik Kirchstraße 19 56412 Gackenbach Germany Single-use Ventilator Breathing Systems Easy, safe, hygienic + Simple handling, fast application for utmost patient safety + Effective heating system prevents rainout + Sterile packaging for optimal hygiene Single-use Ventilator Breathing Systems Product overview P1 for F120 Article Adaptor cable breathing tube heating P1 „GT 500“ Adaptor cable breathing tube heating P1 Perfectly matches the intelligent heating and humidifying control system of StePhanie and SoPhie: internal heating wires and a completely heated expiratory...

 Open the catalog to page 5
Single-use Ventilator Breathing Systems-6

Fritz Stephan GmbH Medizintechnik Kirchstraße 19 56412 Gackenbach Germany Single-use Ventilator Breathing Systems Easy, safe, hygienic + Simple handling, fast application for utmost patient safety + Effective heating system prevents rainout + Sterile packaging for optimal hygiene Single-use Ventilator Breathing Systems Product overview P1 for F120 Article Adaptor cable breathing tube heating P1 Adaptor cable breathing tube heating P1 „GT 500“ Perfectly matches the intelligent heating and humidifying control system of StePhanie and SoPhie: internal heating wires and a completely heated expiratory...

 Open the catalog to page 6

All Fritz Stephan catalogs and technical brochures

  1. EVE_NEO

    6  Pages

  2. EVA_Neo

    6  Pages

  3. FSO2-Systems

    8  Pages

  4. SpaceSuit

    2  Pages

  5. EVE

    8  Pages

  6. Christina

    3  Pages

  7. Sophie

    4  Pages

  8. VentSafe

    2  Pages

  9. NGM 1000

    2  Pages

  10. Portec

    3  Pages

  11. F 120 mobil

    3  Pages

  12. Artec

    3  Pages

  13. Akzent Color

    7  Pages

  14. F 120

    3  Pages

Archived catalogs

  1. Stephanie

    7  Pages

  2. MedAir

    3  Pages

  3. NeoSID Nova

    3  Pages

  4. Alia

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.