video corpo

Stephanie

Stephanie

Stephanie

Product catalog summary
Overview of the STEPHANIE Ventilation System for Neonatology
The STEPHANIE ventilation system, developed by Fritz Stephan GmbH, is designed for neonatology and pediatrics, offering advanced features for respiratory support in newborns and premature infants. It integrates conventional and innovative ventilation modes, patient gas humidification, and monitoring capabilities.

Conventional Ventilation Modes
STEPHANIE supports various conventional ventilation modes including CPAP, S-IMV, A/C, V-CMV, and P-CMV. It features leak-gas compensation to address inspiratory leakage in premature infants and offers patient-triggered ventilation with PSV.

Volume-Limited Ventilation
The system includes a "minimum volume guarantee" to prevent excessive tidal volumes and potential volume trauma by limiting inspiratory pressure once the expiration volume reaches a set limit.

High-Frequency Oscillation Ventilation (HFOV)
HFOV can be activated instantly without changing patient tubes, offering adjustable frequency, amplitude, and I/E ratio. It supports reliable oxygenation with a wide Mean Airway Pressure range and precise monitoring.

Proportional Assist Ventilation (PAV)
PAV reduces resistive and elastic stresses on the lungs, adapting to the patient's spontaneous breathing pattern. It provides safe respiration treatment with continuous monitoring and automatic backup ventilation if needed.

Non-Invasive Ventilation (NIV)
NIV offers lung-protective strategies, reducing air leak syndromes and BPD. The system allows quick transitions between invasive and non-invasive methods, supporting the INSURE method.

Closed Loop Ventilation
This feature uses SpO2 data to adjust backup ventilation automatically, enhancing patient safety by correcting oxygen saturation levels independently.

Patient Gas Conditioning
The integrated humidification system ensures the respiration gas is adequately moistened and warmed, preventing secretion build-up and maintaining high hygienic standards.

Monitoring and Diagnostics
A 10.4" TFT monitor provides comprehensive visualization of respiratory parameters, aiding in optimal diagnostics. It displays detailed curves and loops for pressure, flow, and tidal volumes.

Continuous Development
STEPHANIE is designed for future upgrades, allowing users to benefit from ongoing innovations and maintain cost-effectiveness.
See more

Catalog excerpts

Stephanie-1

Stephanie The ventilation system f Proportional Assist Ventii.ition (PAV) t Integrated patient gas humidifier i Minimum volume guarantee t Innovative „Closed Loop Ventilation" f Dead space free ventilation control with external respiration sensor Synchronized, non-invasive vci fratini:

 Open the catalog to page 1
Stephanie-2

Clinical Experience Technical Competence Steph 3,111 C The ventilation system for neonatology Success in the area of top-class medical technology lies in the details. And it is in these details that the STEPHANIE neonatal ventilation system excels. From the outset, Fritz Stephan GmbH has specialized in solutions associated with ventilation in the area of neonatology and pediatrics. Through its many years of working closely with hospitals, Fritz Stephan GmbH is well aware of the demands medical personnel place on their "tools". The unique combination of ventilator, patient gas humidifier, oscillator...

 Open the catalog to page 2
Stephanie-3

Pediatrics HFO The integrated high-frequency oscillation ventilation (HFOV) can be initiated at the push of a button and without any delay or the necessity of changing patient tubes. The unique patient ventilator means that there are no additional compressible volumes which can reduce the performance of the HFO. Patient gas conditioning The integrated, heated patient gas humidication system generates saturated and warmed respiration gas ahead of the inspiration valve, in other words, “within” the ventilator so to speak. The heated patient tubes provide temperature monitoring when carrying the...

 Open the catalog to page 3
Stephanie-4

Clinical Experience Technical Competence Steph 3,111 C The ventilation system for neonatology High-frequency oscillation The integrated high-frequency oscillation represents one of the characteristics which sets this system apart. It can be activated at the push of a button, and frequency amplitude as well as the I/E ratio are all ad-justable.The wide adjustment range of the Mean Airway Pressure (MAP) up to 30 cmH20 provides reliable oxygenation. The precision monitoring fully developed for STEPHANIE permits even the smallest volumes to be measured during HFOV, even at very high frequencies....

 Open the catalog to page 4
Stephanie-5

Pediatrics PAV is a safe respiration treatment since the spontaneous breathing efforts are continuously monitored and a backup ventilation utilizing conventional S-IMV automatically takes over if the tidal volumes being breathed become too low or if spontaneous respiration stops. The backup ventilation permits a more subtle form of respiration support for children with breathing insufciencies. Apneas or a large reduction of spontaneous breathing in premature infants are characterized by drops in oxygen saturation due to insufcient pulmonary aeration. If an apnea is followed by a resumption of...

 Open the catalog to page 5
Stephanie-6

Clinical Experience Technical Competence Steph 3,111 C The ventilation system for neonatology The integrated, heated humidification system During normal, spontaneous breathing, the respiration gas is moistened and warmed in the upper respiratory tract. Insufficient moisture in the gas or gas which has not been adequately warmed will quickly lead to disruptions in the activities of the cilia in the bron- chial epithelium, to an increase in the viscosity of the respiratory tract secretion and to an increased risk of a partial obstruction of smaller pulmonary path-ways due to a secretion build-up....

 Open the catalog to page 6
Stephanie-7

Optimal diagnostics ""itti the 10.4"TFT The availability of nil relevant parameters un STEPHANIE means optimal mechanical [■(.■spi ratini) di.ignnstics on the part of the physician. The display methods (numeric/graphic) can he -.elected via .i in ¡TI H. Tl ie respiration pi essurc am ,i:ul the inspiration ar.J eviration finvc and tidal volumes are displavcd in detail in the form of curves or respiration ionps. liovund tins, :■. wide \-ni"iijtv ut other diagnostic tools such JS (ht: visualization of die iurrn-puhnnnarv pressure, inadvertent PEEP, or the pulmonary-ti me constant are available to...

 Open the catalog to page 7

All Fritz Stephan catalogs and technical brochures

  1. EVE_NEO

    6  Pages

  2. EVA_Neo

    6  Pages

  3. FSO2-Systems

    8  Pages

  4. SpaceSuit

    2  Pages

  5. EVE

    8  Pages

  6. Christina

    3  Pages

  7. Sophie

    4  Pages

  8. VentSafe

    2  Pages

  9. NGM 1000

    2  Pages

  10. Portec

    3  Pages

  11. F 120 mobil

    3  Pages

  12. Artec

    3  Pages

  13. Akzent Color

    7  Pages

  14. F 120

    3  Pages

Archived catalogs

  1. MedAir

    3  Pages

  2. NeoSID Nova

    3  Pages

  3. Alia

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.