60 WATT MEDICAL & ITE POWER SUPPLIES RoHS DESCRIPTION The PMP60N1 series of AC/DC switching power supplies are for 60 watts of continuous output power. They are enclosed in a 94V-0 rated polycarbonate case with an IEC320/C14 inlet to mate with interchangeable cord for world-wide use. All models meet EN55011, EN55032 class B emission limits, and are designed for medical and ITE applications. See output rating chart. See output rating chart. 1% peak to peak maximum Set at 112-140% of its nominal output voltage, automatic recovery Automatic recovery Automatic recovery ±0.04% /°C maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change See output rating chart ±0.5% maximum at full load 5600 VDC from input to output (2 MOPP) 2100 VDC from input to ground (1 MOPP) 700 VDC from output to ground (To verify AC strength, get correct test method to avoid power supply damage.) 150,000 hours minimum at full load at 25°C ambient, calculated per MIL-HDBK-217F Class B conducted, class B radiated Harmonic distortion, class A and D Line flicker ESD, ±15 KV air and ±8 KV contact Radiated immunity, 9-28 V/m for 80-2500 FEATURES • Operation up to 5000 meters • Optional output connectors • Wide input range 90- 264 VAC • Input surge current protection • Overvoltage protection • Overcurrent protection • Compliant with DoE Efficiency level VI requirements (except PMP60N1 - 1 2) • Compliant with RoHS requirement Input voltage: Input frequency: Input current: Earth leakage current: Touch current: Output voltage /current: Maximum output power: Ripple and noise: Over voltage protection: Short circuit protection: Over temperature protection: Temperature coefficient: Transient response: Switching frequency: Efficiency: Hold-up time: Line regulation: Inrush current: Withstand voltage: Operating temperature: Storage temperature: Relative humidity: Temperature derating: Derate from 100% at +40°C linearly Conducted immunity, 10 Vrms Magnetic field immunity, 30 A/m Voltage dip immunity, 30% reduction for 500
Open the catalog to page 1UNIVERSAL INPUT PMP60N1 MEDICAL & ITE SERIESOUTPUT VOLTAGE/CURRENT RATING CHART Model 1. Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 p F tantalum capacitor in parallel with a 0.1 pF ceramic capacitor across the output. 1. Dimensions shown in inches [mm] 3. Weight: 600 grams (1.33 lbs.) approx. 4. Output connector is 5 pin DIN plug, mating with Switchcraft P/N 57GB5F receptacle or equivalent. 5. Refer to Section titled “OPTIONAL OUPUT CONNECTORS" for optional output connectors. Add...
Open the catalog to page 23 Pages