Pre-Op X-Ray
This section outlines the necessary pre-operative X-ray procedures required before the surgical intervention using EASYTECH instrumentation.
Instrumentation: EASYTECH
The document specifies the use of EASYTECH instrumentation, which involves two trays for the surgical procedure.
Surgical Technique: Humerus
The surgical technique for the humerus includes the use of a cutting guide and determining the cutting size, which corresponds to the head size. The humerus must be centered, and a K-wire is used for alignment. The choice of baseplate is crucial, with sizes ranging from Ø39 to Ø50, each corresponding to specific puncher sizes for proper baseplate impaction. A double taper and trial head are also part of the procedure.
Definitive Implants
The document discusses the use of centered and eccentric definitive implants, ensuring proper alignment and fit.
Instrumentation: Glenoid
Instrumentation for the glenoid involves specific tools and techniques tailored for this part of the procedure.
Surgical Technique: Glenoid
The glenoid surgical technique includes four sizes: XS, S, L, and M. It involves the use of trial implants before placing the definitive implant.
Post-Op X-Ray
This section emphasizes the importance of post-operative X-rays to assess the success of the surgical procedure and the placement of implants.
Reversibility/Revision
The document briefly mentions the potential for reversibility or revision, indicating considerations for future adjustments or corrections if necessary.
See more

Catalog excerpts

EASYTECH-2

 PRE-OP X-RAY  INSTRUMENTATION: EASYTECH  SURGICAL TECHNIQUE: HUMERUS  DEFINITIVE IMPLANTS: EASYTECH  INSTRUMENTATION: GLENOID  SURGICAL TECHNIQUE: GLENOID  POST OP X-RAY  REVERSIBILITY/REVISION

 Open the catalog to page 2
EASYTECH-5

SURGICAL TECHNIQUE: HUMERUS Cu-ng guide

 Open the catalog to page 5
EASYTECH-6

Cu-ng size = Head size

 Open the catalog to page 6
EASYTECH-7

Centered humerus K-­‐wire

 Open the catalog to page 7
EASYTECH-9

Baseplate size = puncher size

 Open the catalog to page 9
EASYTECH-11

Double taper + Trial head

 Open the catalog to page 11
EASYTECH-12

DEFINITIVE IMPLANTS

 Open the catalog to page 12
EASYTECH-13

INSTRUMENTATION: GLENOID

 Open the catalog to page 13
EASYTECH-14

SURGICAL TECHNIQUE: GLENOID

 Open the catalog to page 14

All FX Solutions catalogs and technical brochures

  1. HUMELOCK II

    15  Pages

  2. ACROLIG®

    4  Pages

  3. FLEX NAIL

    2  Pages

  4. P.R.C.T II

    5  Pages

  5. SMARTLOOP

    9  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.