A classic never goes out of style
Open the catalog to page 1Catheter Mount Animal Mask Product Index Symbols and Cleaning Instructions
Open the catalog to page 2In addition to the products about breathing circuits, anesthesia circuits, oxygen therapy, emergency resuscitation, and lung training that you could get information from our other catalogs, accessories, and components also play important roles in respiratory therapy. GaleMed offers a range of accessories for these products, including a variety of catheter mounts, filters, and connectors. These provide safe, ergonomic, comfortable, and practical solutions. Accessories & Components Non-Rebreathing Valves (NRV) 07 Diverter (for PEEP Valve & Filter) 09 Durable Adjustable PEEP Valves 10 Disposable...
Open the catalog to page 3Valves & Reservoir bag of Resuscitators REF Description Material QTY AR0015 MR-100 NRV, Adult PSF 50 pcs/box AR0054 Dispobag NRV, 40cmH2O PC+PP 50 pcs/box Intake Valves Valves & Reservoir bag of Resuscitators REF Description MR-100 Plus Intake Valve Kit AV0086 MR-100 Plus Valve Kit, 5 pcs AR0018 MR-100 Intake Valve Set (w/ valves) AR0049 MR-100 Intake Valve Assy MR-100 Intake Valve Disc AV0053 MR-100 Mushroom Valve for Intake 50 pcs/box 50 pcs/box 50 pcs/box 50 pcs/box 50 pcs/box 50 pcs/box 50 pcs/box 50 pcs/box
Open the catalog to page 4Valves & Reservoir bag of Resuscitators Valves & Reservoir bag of Resuscitators Valves Diverter (for PEEP Valve & Filter) REF Description MR-100 Plus Valve Kit, 5 pcs AR0004 MR-100 Valve Kit, 5 pcs • The Diverter fits on the NRV of the manual resuscitator. • Suitable for attaching: PEEP Valve, HEPA, bacterial/viral filter, or another diverter to change the direction of exhaled air. • Two models available: durable and disposable. 50 pkg/box 50 pkg/box 50 pkg/box MR-100 Diverter, 30/26 mm Durable 50 pcs/box AR0005 MR-100 Diverter, 30/26 mm Disposable 50 pcs/box Reservoir Valve & Bag Diverter Cap...
Open the catalog to page 5Valves & Reservoir bag of Resuscitators Adjustable PEEP Valve Durable Adjustable PEEP Valves • Designed to maintain a correct pressure in the patient’s lungs at the end of the expiratory phase. • Special spring mechanism engineered to compensate the tolerance under different flow rates to maintain high accuracy and consistency. • Colour-coded designed enables to identify different pressure level easily. • Made of PSF material and endurable for repeated sterilization. Adj. PEEP Valve, 2-10cmH2O Adj. PEEP Valve, 2-10 cmH-O Adj. PEEP Valve, 5-20 cmH20 with interchangeable adaptor Adj. PEEP Valve,...
Open the catalog to page 6Valves & Reservoir bag of Resuscitators FILTER RANGESBV Filter & HMEF REF Dead Space Heated and moisture exchanger (HME) Paper media Foam media Foam media Paper Media Paper Media Luer Electrostatic/ Foam Luer Paper Media Luer GaleMed Corporation
Open the catalog to page 7Valves & Reservoir bag of Resuscitators Heat and Moisture exchange filter (HMEF) & Filter Heat and Moisture exchange filter (HMEF) & Filter Heat and Moisture Exchanger (HME) (D Heat and Moisture Exchanger Filter (HMEF) ® Trachea Humi.AIDE™ HMEF is a 2-in-1 device that offers passive humidification of respiratory air and electrostatic filtration of bacteria and viruses to minimize infection between the patient and other healthcare practitioners. It is designed to work on patients with mechanical ventilation under critical care or anesthesia, to ensure minimal loss of heat and moisture from respiratory...
Open the catalog to page 8Valves & Reservoir bag of Resuscitators Heat and Moisture exchange filter (HMEF) & Filter Heat and Moisture exchange filter (HMEF) & Filter Heat and Moisture Exchanger Filter (Filter) Heat and Moisture Exchanger Filter (Filter) (D Bacterial Filter (Foam filtering medium)• Equipped with 0.3 micron bacterial filter membrane for up to 99.99% of efficiency. • Standard 22 mmlD/15 mmOD and 22/15 mm connectors meet ISO Standard. • Material: polypropylene. Viral / Bacterial Filter High efficiency bacterial filter to minimize cross-contamination between patients, equipment and other healthcare practitioners....
Open the catalog to page 9Valves & Reservoir bag of Resuscitators Heat and Moisture exchange filter (HMEF) & Filter Heat and Moisture exchange filter (HMEF) & Filter Tracheal Heat and Moisture Exchanger (tHME) ® Tracheal Heat and Moisture Exchanger (tHME) ® The Humi.AIDE™ Tracheal Heat and Moisture Exchanger (tHME) provides passive humidification for spontaneously breathing tracheostomy patients. The tHME is designed with a standard 15mm fitting for attachment to the patient's tracheotomy tube. The tHME has a compact and lightweight design that reduces pressure at the sensitive trachea site and helps provide optimum patient...
Open the catalog to page 103-Way Manifold The 3-Way Manifold is attached to the single limb breathing circuit to regulate the expiratory valve. The control line from the ventilator controls the opening of the valve to enable air to flow in and out accordingly. This line intermittently provides the pressure needed to close the expiratory valve during inspiration, which blocks gas outflow during the application of inspiratory positive pressure. This is done to ensure the patient receives optimal gas exchange conditions. Durable 3-Way Manifold © Disposable 3-Way Manifold • The durable 3-Way Manifold with Exhale Port also...
Open the catalog to page 112-Way Manifold The 2-Way Manifold is used to regulate the flow for the expiratory of the dual limb breathing circuits. The control line Control line from the ventilator controls the opening of the valve to enable air to flow out accordingly. Exhale • Pressure & Flow Rate: < 4.52 cmH:0 @ 60 LPM (AV0078). Durable 2-Way Manifold REF Description Port QTY AV0078 Durable 2 Way Manifold - 60 pcs/carton AV0079 Durable 2 Way Manifold W/7.6F Port 7.6F 60 pcs/carton Dispo. 2 Way Manifold w/Elbow Drive Port Dispo. 2 Way Manifold w/Straight Drive Port Catheter Mount 2-Way Manifold with Water Trap ■ CS Water...
Open the catalog to page 12Catheter Mount Catheter Mount Catheter Mount Catheter Mount ® A Catheter Mount provides extensions and airway connectors to make it easier for patient positioning, reducing unexpected ventilator disconnection and freeing caregivers from continuous monitoring. A catheter mount is made of three major parts, (1) patient connector (elbow or straight connectors), (2) extension tubing and (3) circuit connectors. • Flexible and soft silicone tubing. • 360° swivel connector designed for more flexibility. • 15M port with cap for suction or insertion of other functional tubes. We offer a wide range of...