

Catalog excerpts

medical central gas supply system Edition 1/2013 For safety and service reasons a central gas system must be equipped with shut-off valves placed so that the gas supply can easily be interrupted. The valves are mounted in a box. The emergency shut-off valve boxes shall be placed so that the gas can be shut off section wise. This means that the boxes should be placed before each ward, operating unit, part of ward for critical treatment and individual surgeries. The emergency shut-off valve box is delivered with connection tubes and each box has been test pressurized and controlled for tightness. The emergency shut-off valve has large ergonomical handles. If mounted in a recessed way, the emergency shut-off valve box fits walls with 70 mm beam. With a 90 mm beam there is extra space (23,5 mm) behind the valve box usable for e.g. fire isolation. All models, also with four or five gases, fit between the beams in a CC-60 wall. The box is gas-tight which prevents gas accumulation inside the wall. It is important that the boxes are placed so that they are easily available for authorized personnel. The front door shall be sealed. In order to avoid mistakes the boxes shall be clearly and distinctly marked with gas sort. A sign showing which section the box serves must be placed in its immediate vicinity. The valves are open when the handles are in vertical position in line with the printed marking on the plate.
Open the catalog to page 1
Shut Off ValVe BOx DN 15, DN 20 tecHnical data Gases: Number of gases: O2 ; N 2O; Air;Air-800(I-Air); CO2 ; N 2 ; VAC (all medical gases) (ø15×1) 1 to 5 valves (DN 15) (ø22×1) 1 to 3 valves (DN 20) 10 bar ø15×1 mm; ø22×1 mm Brass; Copper 4 - 15 kg Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System) and current SIS HB 370. Working pressure: Tube dimension: Material: Weight: Regulatory status: 1-3 VALVE BOX FROM ABOVE EXPOSED MOUNTING SEEN FROM SIDE RECESSED MOUNTING SEEN FROM SIDE 4-5 VALVE BOX FOM ABOVE Note! Measurements in mm. EXPOSED...
Open the catalog to page 2All GCE Group catalogs and technical brochures
-
APTECh
8 Pages
-
MASS FLOW CONTROLLER
16 Pages
-
GCE GROUP VALVES
12 Pages
-
MEDIVITOP®
4 Pages
-
GCE CENTRAL GAS SYSTEMS
408 Pages
-
HEALTHCARE CATALOGUE
64 Pages
-
MEDIVITAL®
4 Pages
-
CENTRAL GAS SUPPLY
48 Pages
-
APTECH - UHP CATALOGUE
6 Pages
-
HP DRUVA CATALOGUE
49 Pages
-
Zeno_Brochure
8 Pages
-
MEDICAL CENTRAL GAS
48 Pages
-
HEALTHCARE CATALOGUE
44 Pages
-
VALVES
12 Pages
-
Leaflet_Suction_jars
2 Pages
-
Zeno_lite
2 Pages
-
MFC CATALOGUE
16 Pages
-
TECHLINE CATALOGUE
48 Pages
-
speciality gas equipment
112 Pages
-
MEDIEVAC+
2 Pages
-
Medivital
4 Pages
-
VARIMED
2 Pages
-
MEDISELECT® II
4 Pages
-
MEDIEJECT PLASTIC
2 Pages
-
NUVO 8
2 Pages
-
APS II
4 Pages
-
GSS
2 Pages
-
MM90 - HP UNIT AUTO
2 Pages
-
MM40 - HP UNIT SEMIAUTO
4 Pages
-
PRESSURE WATCH DN20
4 Pages
-
PRESSURE MONITOR DN15
2 Pages
-
GCE MEDIUNIT DIN TYPE
2 Pages
-
GCE MEDIUNIT CZ TYPE
2 Pages
-
GAS ALARM MC7701
2 Pages
-
GAS ALARM G4
2 Pages
-
GAS ALARM C44
2 Pages
-
MEDIWET
2 Pages
-
Medimeter
2 Pages
-
MediEject
2 Pages
-
BAG VALVE MASK
2 Pages
-
Inogen One® G3
2 Pages
-
Inogen One® G2
2 Pages
-
Elite
2 Pages
-
ECOlite® 4000
2 Pages
-
EASE II
2 Pages
Archived catalogs
-
MEDIEVAC+ Old
2 Pages