Overview
The ImageQuant LAS 4000 is a digital imaging system designed for sensitive and quantitative imaging of gels and blots using chemiluminescence and fluorescence. It offers flexibility with various light sources and filters, and can be upgraded for infrared fluorescence imaging. The LAS 4010 model includes additional UV and visible light sources.
Key Features
  • Wide Linear Dynamic Range: Captures signals over four orders of magnitude, eliminating the need for multiple exposures.
  • High Resolution: Provides accurate quantitation of gels and films up to 21 × 14 cm with a resolution of up to 6.3 Mpixels.
  • Low Noise: The camera is cooled to -25°C, reducing background noise for precise quantitation of weak signals.
  • High Sensitivity: Capable of detecting signals down to picogram levels of target protein.
  • Uniform Quantitation: Applies corrections for optimal precision in each imaging mode.
  • Multifluorescence Detection: The LAS 4010 can image a wide range of UV- and RGB-excited labels and stains.
Technical Specifications
  • CCD Model: Fujifilm Super CCD Area Type
  • Lens Model: FUJINON Lens F0.85 43 mm
  • Cooling: Two-stage thermoelectric module with air circulation
  • Dynamic Range: 16-bit, 4 orders of magnitude
  • Image Resolution: Maximum 3072 × 2048, 6.3 Mpixels
  • Interface: USB 2.0
  • Dimensions: 510 × 900 × 480 mm
  • Weight: 60 kg
Imaging Applications
  • Quantitative Western Blotting: High sensitivity for capturing chemiluminescent signals.
  • UV Fluorescence: Standard features include UV transilluminator for fluorescence detection.
  • Infrared Fluorescence: Optional epi-infrared light and filter set available.
  • Gel Documentation: Imaging of opaque stains and colorimetric Western blotting applications.
Performance and Compatibility
  • Compatible with a wide range of fluorescent dyes and imaging applications.
  • Upgradeable to match the performance of the LAS 4010 model.
Ordering Information
  • ImageQuant LAS 4000: Code no. 28-9558-10
  • ImageQuant LAS 4010: Code no. 28-9558-11
  • Various upgrade sets and accessories are available for enhanced functionality.
Product Overview: The document details components and accessories for the i-UV Set (LAS) and related imaging equipment, including UV Epi light, calibration plate FL, L41 UV filter, and various trays and lenses.
Specifications: Lists product codes and descriptions for accessories like the White EPI light set, W-Lens Set, UV-Trans Tray Set, and others, designed for specific imaging applications.
Minimum Computer Requirements: Requires Windows XP SP3 or Vista Business SP1 (32-bit), over 1 GB RAM, Intel Core 2 Duo processors, over 80 GB hard disk space, USB 2.0 ports, and a monitor with at least 1280 × 1024 resolution.
Licensing and Trademarks: Outlines licensing agreements for products like CyDye and Deep Purple Total Protein Stain, emphasizing internal research use only. Commercial use requires a separate license with GE Healthcare.
Contact Information: GE Healthcare provides contact details for regional offices in Sweden, the UK, the USA, Germany, and Japan for inquiries and support.
Legal and Trademark Notices: Includes legal disclaimers about trademarks and licensing, noting that all goods and services are subject to GE Healthcare's terms and conditions of sale.
See more

Catalog excerpts

ImageQuant LAS 4000 data file-1

GE Healthcare Data file 28-9610-74 AB Imaging systems, software, and accessories ImageQuant™ LAS 4000 biomolecular imager ImageQuant LAS 4000 (Fig 1) is a digital imaging system for sensitive, quantitative imaging of gels and blots, by chemiluminescence and fluorescence. A flexible combination of light sources and filters can be incorporated into the imager according to your needs. ImageQuant LAS 4010 is a model that is fully equipped with light sources for ultraviolet (UV) and visible (RGB) imaging. Both 4000 and 4010 models can be upgraded to perform infrared (IR) fluorescence imaging. ImageQuant LAS 4000 delivers: • Wide linear dynamic range: Capture and precisely quantitate weak and strong signals over four orders of magnitude in the same image, avoiding time-consuming multiple film exposures. • High resolution: Accurate quantitation of gels and films up to 21 × 14 cm in size. Up to 6.3 Mpixel image resolution is achieved via a unique diagonal pixel configuration. • Low noise: The camera is typically cooled to -25°C (maximum -35°C) enabling longer exposure times giving less background, which is especially important for precise quantitation of very weak signals in chemiluminescent Western blotting. • High sensitivity: ImageQuant LAS 4000 captures fluorescent and chemiluminescent signals on a Western blot down to picogram levels of target protein. Sensitivity may be increased by binning of up to 8 × 16 pixels. • Uniform quantitation: Distortion, dark frame, and flat frame corrections are applied to each imaging mode for optimal precision. • Multifluorescence detection: ImageQuant LAS 4010 extends functionality to image a wide range of UV- and RGB-excited labels and stains. Fig 1. ImageQuant LAS 4000 is a highly sensitive, CCD camera-based quantitative biomolecular imager. Description ImageQuant LAS 4000 is a sensitive imager for chemiluminescence, UV transillumination, and white epi-illumination imaging applications. ImageQuant LAS 4010 is additionally equipped for epifluorescent UV and RGB applications, as well as white transillumination. The system consists of an intelligent dark box, camera, lens, and automated five-position filter wheel with a standard filter for EtBr and open positions for the filters delivered with the optional fluorescent light sources. The system is simple to operate. Focusing, filters, illuminators, and exposure time are remotely controlled by a computer without having to open the cabinet. High resolution and precise quantitation of low signals are achieved using a multipurpose 16-bit, 3.2 Mpixel camera fitted with a large aperture F0.85 lens. The system has an automated iris, and responds rapidly when changing focus and settings. Chemiluminescent and colorimetric signals can be captured without changing the lens.

 Open the catalog to page 1
ImageQuant LAS 4000 data file-2

Technical features Sensitive chemiluminescence detection: The system is optimal for quantitation of chemiluminescent Western blots. F0.85 43 mm LAS high sensitivity lens F1.8 24 mm SIGMA™ wide view lens Gel documentation and quantitation: colorimetric-stained samples are easily imaged. Easily exchangeable light sources and filters: The system can image a wide range of fluorophores, and is easily adapted for use in multiple applications; filters and light sources are exchangeable in seconds. UV, red, green, blue, and IR light sources for epifluorescence as well as white light are available. Two...

 Open the catalog to page 2
ImageQuant LAS 4000 data file-3

Imaging applications ImageQuant LAS 4000 is a single platform for multiple imaging applications. The UV transilluminator for fluorescence detection of reagents such as EtBr (Fig 4), Deep Purple Total Protein Stain, and epi light sources for fluorescence detection of reagents such as SYPRO™ Rose and Qdot™ are provided as standard features. Quantitative Western blotting The high sensitivity of the system is designed to capture the chemiluminescent signals from Amersham™ ECL™, ECL Plus (Fig 3), and ECL Advance™ Western blotting reagents for quantitative purposes. Sample: Membrane: Detection: Transferrin...

 Open the catalog to page 3
ImageQuant LAS 4000 data file-4

Large gels Imaging of opaque stains such as Coomassie Blue, silver stain, and Amersham Rainbow™ markers and colorimetric Western blotting applications is achieved by standard epiwhite illumination or optional white transillumination (Fig 6). With the optional SIGMA F1.8 wide view lens, gels up to 25 × 25 cm can be imaged. Each imaging mode has individual settings for flat frame and dark frame corrections for uniform field imaging. Table 3. Optional filters for fluorescence Carbonic anhydrase 32 Sample: LMW marker Stain: Coomassie Blue Imaging: White transillumination LOD: 16 ng carbonic anhydrase...

 Open the catalog to page 4
ImageQuant LAS 4000 data file-5

Imager performance Chemiluminescence Amersham ECL Amersham ECL Plus Amersham ECL Advance Fluorescence via UV transilluminator (312 nm) EtBr + + Deep Purple + + SYBR Green I & II + + SYBR Gold + + Fluorescence via UV epi-illuminator (365 nm) EtBr + SYPRO Rose + Qdot 605, 655, 705, 800 + Fluorescence via blue epi-illuminator (460 nm) Alexa Fluor™ 488 + Cy2 + SYBR™ Green I & II + SYBR Gold + SYPRO Ruby + SYPRO Orange + FITC + FAM™ + EGFP + ECFP + AttoPhos™ + ECL Plus + Pro-Q™ Emerald 488 + Fluorescence via green epi-illuminator (520 nm) SYPRO Red + Cy3 + TAMRA™ + 5-ROX™ + HEX™ + Alexa Fluor 532,...

 Open the catalog to page 5
ImageQuant LAS 4000 data file-6

Ordering information System Upgrades and accessories Code no. * For chemiluminescence, UV transillumination, and white epi-illumination imaging applications. Includes intelligent dark box, camera head, F0.85 43 mm LAS high sensitivity lens, calibration plates DI and FL (green), AC cable (EU and USA), USB cable, operation manual, auto filter changer, UV transmitted light source, white epi-light source, EtBr detection filter, EPI tray, UV transmission tray, and 10 gel sheets. White light set, 1 pair F1.8 24 mm SIGMA wide view lens and F-mount adapter UV transmission tray and 10 gel sheets Pack...

 Open the catalog to page 6

Archived catalogs

  1. ÄKTAprocess

    4  Pages

  2. ÄKTApurifier

    12  Pages

  3. ÄKTAmicro

    8  Pages

  4. ÄKTA avant

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.