1. Catalogs
  2. GEEVO TECHNOLOGY
  3. Aseptic Isolation Teschnology- hangzhou Geevo
video corpo

Aseptic Isolation Teschnology- hangzhou Geevo

Aseptic Isolation Teschnology- hangzhou Geevo

Aseptic Isolation Teschnology- hangzhou Geevo

Product catalog summary
Aseptic Isolation Technology Overview
Aseptic Isolation Technology is increasingly adopted by leading pharmaceutical and biotechnology companies globally. It is essential for sterility testing, providing a controlled clean environment to ensure product and operator safety. Key performance characteristics include sealing system integrity, effective surface sterilization, and maintaining an aseptic state.
Applications
  • Sterility Testing Isolator
  • Production Isolator
Used in microbial laboratories for sterility tests of sterile preparations and raw materials, recommended by ChP, USP, EP, and JP to avoid false positives. In pharmaceutical production, it supports aseptic processes like subpackaging, sampling, dosing, and weighing, protecting both product and operator.
Sterility Test Isolator Features
  • Customizable for various batch sizes and process flows.
  • Constructed from stainless steel and toughened glass with glove ports.
  • Automatic control via PLC system, compliant with GMP, EP, USP, CP.
  • Operates in Class D background, achieving dynamic Class A inside.
Technical Features
  • Smooth interior for improved cleanability and decontamination.
  • Integrated Siemens PLC control system with HMI monitoring.
  • Vertical unidirectional airflow with HEPA H14 filtration (99.995% efficiency).
  • Hydrogen Peroxide fogging technology for sterilization, achieving 6-log reduction of spores.
Main Technical Parameters
  • Class A cleanliness in working area.
  • Adjustable pressure difference (20-50Pa) during sterility tests.
  • H2O2 concentration range: 0-2000ppm, displayed as a curve graph.
  • Residual H2O2 limit: <1ppm.
  • Noise level: ≤65dB(A).
  • Compliance with FDA 21 CFR Part 11 for data integrity and safety.
Options and Accessories
  • Air Sampler, Particle Counter, RTP (Rapid Transfer Port).
  • Automatic glove leak tester, chemical indicators, αβ valve.
Contact Information
Hangzhou Geevo Technology Co., Ltd.
Tel: +86-571-89938051
Fax: +86-571-89937093
Email: [email protected]
Address: No.18 Wuzhou Road, Yuhang Economic & Technical Development Area, Hangzhou, Zhejiang, China
See more

Catalog excerpts

Aseptic Isolation Teschnology- hangzhou Geevo-1

ASEPTIC ISOLATION TECHNOLOGY The Optimum Aseptic Containment Solution for Pharmaceutical Industry Hangzhou Geevo Technology Co., Ltd.

 Open the catalog to page 1
Aseptic Isolation Teschnology- hangzhou Geevo-2

Aseptic Isolation Technology This technology is a fast-growing trend among first-class pharmaceutical and biotechnology companies around the world. Today, the use of Isolators has become standard practice for sterility testing. Aseptic Isolator system is a set of integrated system which providing a controlled clean environment to ensure product safety or operator safety. Its performance characteristics are mainly reflected in the integrity of the sealing system, the effectiveness of the surface sterilization procedure, the ability to maintain the aseptic state and so on. • Sterility Testing Isolator...

 Open the catalog to page 2
Aseptic Isolation Teschnology- hangzhou Geevo-3

Feature Smooth interior Smooth flushed interior of Isolator glazing means less crevices to improve clean ability and decontamination effect. Main material: SS304 and toughened glass Integrated Siemens PLC control system and HMI monitoring screen The operation information of each parameter will be displayed on the display screen by data or curve, such as, air tightness, temperature, humidity, H2O2 concentration, wind speed, etc., for easy observation. Access control by password at 4 levels. Meet FDA 21 CFR Part11 Air flow and HEPA Adopts vertical unidirectional flow, air will pass through the...

 Open the catalog to page 3
Aseptic Isolation Teschnology- hangzhou Geevo-4

Main Technical Parameter Technical Parameter Cleanliness of working area Pressure difference during sterility test step Sterilization method Integrated with temperature and humidity H2O2 concentration measuring range 0-2000ppm, display as curve graph Residual allowable limit HEPA H14 (filtration efficiency: 99.995%) Touch screen Control system Input & output Embed steritest pump Glove holder Sample rack Real time printer Emergency switch Reservation port for air sampler Reservation port for particle counter Data integrity and safety Air Sampler, Particle Counter RTP (Rapid transfer port) Automatic...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.