Catalog excerpts
GERSTEL Opioids/Cocaine Solution System Components The GERSTEL Opioids/Cocaine Solution is an automated solution for the quantitative determination of opioids, cocaine and metabolites in blood serum. The components which are part of the system are listed below. All chemicals, the hardware and consumables required for the manual part of the sample preparation as well as the GC/MS analytical system are not included in the scope of delivery. Technische Änderungen vorbehalten. 01-062014 • Analysis of opioids, cocaine and metabolites from blood serum (0.6 mL) • Complete automation of sample preparation and injection into the GC after manual protein precipitation and addition of internal standards: –– Solid Phase Extraction (SPE), –– Evaporation of the eluate, –– Derivatisation, –– Injection into a CIS, –– GC/MS analysis • 97 samples in one sequence • 29 samples per day • Calibration range: –– Cocaine: 5-300 ng/mL, –– Benzoylecgonin: 50-1500 ng/mL, –– Methadone: 25-1500 ng/mL –– Morphine: 5-300 ng/mL –– Codeine: 2.5-150 ng/mL –– 6-Monoacetylmorphine: 2.5-150 ng/mL –– Dihydrocodeine: 5-300 ng/mL –– 7-Aminoflunitrazepam: 2.5-150 ng/mL Also pay attention to the specification sheets of the individual system components. Hardware • MultiPurpose Sampler MPS Dual Head, both towers equipped with gas supply • Solid Phase Extraction SPE for 1 mL cartridges, heating and shaking function are deactivated • Multi Position Evaporation Station mVAP with condenser pump, only one evaporation position can be used • Standard agitator • 2× Solvent Filling Station SFS 2 • Tray for SPE cartridges, 98 positions • Tray on standard tray holder for samples, 98 positions • Tray on standard tray holder for eluate vials, 98 positions • Standard wash
Open the catalog to page 1Opioide/Cocaine Solution • 2.5 mL syringe for sample preparation, right sampler • Consumables for one sample sequence: - column, - liner, - vials, - caps, - SPE cartridges Methods • Analysis method • Quantification method • Example sequence for GC MassHunter Software with integrated MAESTRO software, • Detailed description of analysis method System Requirements For operation of the Opioide/Cocaine solution the system must fulfill the following requirements. • Coupling to an 7890 GC / 5977 MSD system (Agilent Technologies). Must be configured separately (mounting hardware as well) • Agilent...
Open the catalog to page 2All Gerstel GmbH & Co. KG catalogs and technical brochures
-
MPS liquid
4 Pages
-
MPS robotic
16 Pages
-
3-MCPD
4 Pages
-
GERSTEL Twister®
4 Pages
-
Thermal Desorption System TDS
12 Pages
-
MPS Agitators
1 Pages
-
MAESTRO Software
4 Pages
-
MPS robotic series
16 Pages